Description: Specialities:
* Response speed:over 100 meters per second;
* No intermediate interface is needed over 100 meters long-distance data transmission;
* Five
bearings for excellent reorientation;
* Multiple-shielding and soft
metal cable protection and excellent anti-jamming and water- proof for EMI;
* Anode process of Aluminum alloy for etching proof;
* Anti-dust sealing is made by special plastics, with lower friction;
* Easy installation and maintenance by special design, with
good watering-proof and dust-proof;
* The sensors adopt the
glass precise computation as the measuring benchmark;
Specification:
Series type Accuracy Output signal Available length Resolution Distance R1 Work speed
WTA01
¡À(5+5LO/1000)µm;Additional
¡À(3+3LO/1000)µm or more above accuracy
2 TTL square wave 0º and 90º; Additional4 TTL square wave 0º,90º ,180º and 270º
50-1000 0.0001 0.02mm 50mm 6m/min
WTA02
50-1000 0.0002 0.02mm 50mm 15m/min
WTA05
50-1000 0.0005 0.02mm 50mm 30m/min
WTA1
50-1000 0.001 0.02mm 50mm 50m/min
Other data
Phase error:90º¡À15º Operatig temperature:0º-40º
Storage temperature:-20º-50º
WTA
Normal size:L0=50-1000mm,scalea are available in every 50mm.
L0=1000-3000mm,
scale are available in every 100mm;
Max.travel=normal size+30mm (=900mm)
Signal cable=5m
WTA installing size graph
Nominal travel(L0) L0:50-3000, 50mm/level
Max. travel(L1): L1=L0+50(nominal travel ›900) L1=L0+30(nominal travel<=900)
Mounting length(L2) L2:L2=L0+152(nominal travel ›900) L2=L0+132(nominal travel<=900)
Max. Body Dimension L3:L3=L0+169(nominal travel›900)
L3=L0+149(nominal travel<=900