You are here : Home arrow Showroom arrow Products arrow Products arrow Ionizing Air Fan
shenzhen maxsharer import&export co.,ltd

Ionizing Air Fan

Ionizing Air Fan

Keywords:
Post Date: 2007-12-26
Description:
MS-Y0101 TABLE MODEL IONIZING AIR BLOWER ----[INTRO]
MS-Y0101 TABLE MODEL IONIZING AIR BLOWER It is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.Apply to eliminate electrostatic in a limited distance, convenient to remove and install.The ionizing air volume can be adjusted, including high voltage generator.

Specification:
Operating Voltage 110V/60HZ OR 220V/50HZ
MS-Y0101

Current Consumption 0.25A OR 0.12A
Operating Temperature -10~50℃
Size 90mm(L)�170mm(W)�260mm(H)
Weight 3.3Kg
Air Volume 45~110CFM
Ion Balance 0V�10V
Air Coverage 40cm�60cm
Decay tdst Results:
Testing Conditions Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH
Distance 300mm 600mm 900mm
Decay time Positive 1.2s 2.5s 3.9s
Negative 1.3s 2.6s 4.1s
Offset voltage Positive 8V 5V 4V
Negative -7V -6V -3V
MS-Y0102 SUSPENDED IONIZING AIR BLOWER----[INTRO]
MS-Y0102 SUSPENDED IONIZING AIR BLOWER, It is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.Apply to eliminate electrostatic in a space. The double header ionizing air volume can be adjusted, including high voltage gene-rator.

Specification:
Operating Voltage 110V/60HZ OR 220V/50HZ

MS-Y0102

Current Consumption 0.9A OR 0.4A
Operating Temperature -10~50℃
Size 600mm(L)�90mm(W)�170mm(H)
Weight 7.8Kg
Air Volume 80~220CFM
Ion Balance 0V�10V
Air Coverage 40cm�90cm
Decay tdst Results:
Testing Conditions Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH
Distance 300mm 600mm 900mm 1200mm
Left300mm 1.3s 2.4s 2.8s 4.9s
Center 2.8s 1.7s 3.2s 3.6s
Right300mm 1.2s 2.1s 3.0s 4.5s
MS-Y0103 SUSPENDED IONIZING AIR BLOWER----[INTRO]
MS-Y0103 SUSPENDED IONIZING AIR BLOWER, It is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.Apply to eliminate electrostatic in a space. The triple header ionizing air volume can be adjusted, including high voltage generator.

Specification:
Operating Voltage 110V/60HZ OR 220V/50HZ

MS-Y0103

Current Consumption 1.25A OR 0.62A
Operating Temperature -10~50℃
Size 1100mm(L)�184mm(W)�110mm(H)
Weight 12.8Kg
Air Volume 120~330CFM
Ion Balance 0V�10V
Air Coverage 40cm�120cm
Decay tdst Results:
Testing Conditions Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH
Distance 300mm 600mm 900mm 1200mm
Left300mm 1.9s 2.5s 5.1s 8.6s
Center 1.3s 2.3s 4.3s 8.3s
Right300mm 1.8s 2.6s 4.8s 8.5s
MS-Y0104 HORIZONTAL IONIZING AIR BLOWER----[INTRO]
MS-Y0104 HORIZONTAL IONIZING AIR BLOWER, On the base of design of ST105A horizontal ioni-zing air blower, it is smaller and more portable.Can install ionizing equilibrium measurement realtime supervising and alarming system as request.The ionizing air volume can be adjusted, including high voltage generator.

Specification:
Operating Voltage 110V/60HZ OR 220V/50HZ
MS-Y0104

Current Consumption 3.0A OR 1.5A
Operating Temperature -10~50℃
Size 400mm(L)�220mm(W)�190mm(H)
Weight 5.8Kg
Air Volume 70~120CFM
Ion Balance 0V�10V
Air Coverage 60cm�120cm
Decay tdst Results:
Testing Conditions Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH
Distance 300mm 600mm 900mm 1200mm
Left300mm 1.3s 2.5s 3.9s 6.6s
Center 1.1s 2.2s 3.6s 6.5s
Right300mm 1.2s 2.3s 3.8 6.3s
MS-Y0105 HORIZONTAL IONIZING AIR BLOWER----[INTRO]
MS-Y0105 HORIZONTAL IONIZING AIR BLOWER, It is designed as the theory of alternating current electrostatic eliminator, belongs to electrical category.Flat- wide big air volume design apply to eliminate electrostatic in a wide space.The ionizing air volume can be adjusted, including high voltage generator.

Specification:
Operating Voltage 110V/60HZ OR 220V/50HZ
MS-Y0105

Current Consumption 3.0A OR 1.5A
Operating Temperature -10~50℃
Size 570mm(L)�220mm(W)�190mm(H)
Weight 8.5Kg
Air Volume 70~120CFM
Ion Balance 0V�10V
Air Coverage 80cm�120cm
Decay tdst Results:
Testing Conditions Test voltage:1KV-100V Operating Voltage:110/220V Temperature:22℃ Test Humidity:75%RH
Distance 300mm 600mm 900mm 1200mm
Left300mm 1.8s 2.5s 5.2s 8.6s
Center 1.3s 2.2s 4.3s 7.5s
Right300mm 1.7s 2.3s 4.8s 8.3s
MS-Y0106 IONIZING AIR BLOWER----[INTRO]
MS-Y0106 IONIZING AIR BLOWER, is a high efficient, long-distance, large-area blower type electrostatic eliminator, belongs to industrial category.Widely used in various mechanical equipment, including high voltage generator.

Specification:
Operating Voltage 220V-380V 50/60HZ 3phasc

MS-Y0106

Current Consumption 2.0A OR 1.1A
Operating Temperature -10~50℃
Integrated Power Supply 7.0kv
Size 547mm(L)�360mm(W)�230mm(H)
Weight 16Kg
Air Volume 350~430CFM
Discharge Time
Place of Origin:China
Delivery Lead Time :days

More products from this supplier

Didn’t find what you want? Post a buying lead

Send a message
Print Page
E-mail
About Us |  Products  |  Trade Leads