Description: Working principle of SLM-T:
1) Researched and developed successfully by using non-polar set point
adjustments and voltage regulating
technology for high impedance
2) Input voltage is inputted to SCM by limited sampling, low voltage
filtering, signal reshaping, A/D conversion
3) SCM sends out the control signal, after signal is amplified and the
power driving switched, it will adjust the output voltage
4) Compared with the currently used tune-reactance voltage regulation
technique all over the world, this
technology does have its advantage
a) Will not produce harmonic waves and can start the load directly
b) No limitation to load current surge coefficient
c) Thevenin input
network has a high impedance state
d) Suppresses transient input voltage and current
e) Good effects during the actual application in the field and have
good stability under load running
SLM-T technical data:
1) Supply voltage: AC380V
2) Frequency: 50Hz
3) Control voltage: AC220V
4) Working voltage: AC205V-AC240V
5) Output voltage (voltage wave form): no distortion
6) Content of harmonic: <1%
7) Environmental temperature
8) Operating temperature: -10 ~ 45<sup>o</sup>C (at altitudes below 2km)
9) Storage temperature: -25 ~ 60<sup>o</sup>C
10) Protection:
a) Overload protection when load current ≥1.25Ie
b) Over-temperature protection when temperature rises above 80
(Ta=25<sup>o</sup>C)
c) Under-voltage protection when output voltage <180V
d) Insulation: 2.5kV insulation between
power supply control circuit
and external shells
11) Applicable range:
a) Applies to street lamps,
lighting lamps and lanterns
b) Gas discharge
lamps such as high voltage sodium lamps, mercury lamps,
halogen
lampsKey characteristics of SLM-T products:
1) Microcomputer used for control, easy to use and user-friendly
2) Runs on its own, can be switched on/off by customer's auto-control system
3) Warm-up time can fully satisfy the load start-up
4) Step-to control
power saving rate (
power saving rate I, II, III, IV)
5) Auto-alarm by system bypass when the current is 1.25 times than the rated
current
6) Auto-alarm by system bypass when output voltage is under 180V
7) Load current auto-inspecting function
8) System switches to full voltage output when no load current is detected
9) System switches to warm-up state when load current is detected
10) Manual forced bypass function, failure bypass function
SLM-T protection functions:
1) Over load protection
2) Over temperature Protection
3) Output under voltage protection
| Place of Origin: | China |
|---|
| Payment Terms : | T/T |
|---|
| Delivery Lead Time : | 7 days |