Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

10kv Transformer Ipf Dielectric Loss Tangent Tan Delta and Capacitance Tester

Price $2800.00
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 338 people viewed
Model NO.:
HM5006
After-sales Service:
Life Time Support
Warranty:
1 Year or Extended
Type:
Transformer Tester
Display:
LCD
Weight:
28kg
Power Source:
180V-270VAC, 50Hz/60Hz+-1%
Test Current Range:
10μa-1A
Resolution:
Maximum 0.001PF, 4 Valid Figures.
Maximum Output Current:
200mA
Relative Humidity:
<90%
External Hv:
3PF-1.5μf/10kv 60PF-30μf/0
Tgδ Range:
Unlimited, 0.001% Resolution
Certificate:
CE
Calibration Report:
Factory Report or The Third Party Report
Capacitance Range:
Internal Hv: 3PF~60000PF/10kv 60PF~1μf/0.5kv
Test Method:
Gst, Ust, CVT Ratio
Model Input:
220V or 120V
Frequency Input:
50Hz or 60Hz
The Max Output:
10kv, 12kv, 15kv or Higher
Function:
Can Be Customzied
Funtion 2:
for Transformer Tan Delat Test and CVT Ratio Test
Trademark:
HMDQ
Transport Package:
Wooden Box with Foam Inside
Specification:
460mm*360mm*350mm.
Origin:
Hubei, China(Mainland)
HS Code:
9030899090
Product Description
10kV transformer IPF  dielectric loss Tangent  tan delta  and capacitance tester
 
I. Summary

Tan Delta Test Set is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test. Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property. It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. 

II. Technical indicators
Accuracy: Cx: ±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference. 
Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
 External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV
 Resolution: Maximum 0.001pF, 4 valid figures. 
tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. 
Test current range: 10μA~1A
Internal HV: Set voltage range: 0.5~10kV
Maximum output current: 200mA
 Buck-bust method: continuous stepless regulation
 Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
Frequency accuracy: ±0.01Hz
External HV: In case of UST, maximum test current is 1A,and power frequency or variable frequency is 40-70Hz
In case of GST, maximum test current is 10kV/1A,
and power frequency or variable frequency is 40-70Hz
CVT self-exciting low voltage output: Output voltage 3~50V,
output current 3~30A


V. Company profile photos

Wuhan Goldhome Hipot Electrical Co.,ltd is an ISO certified factory specially in  manufacture electric test equipment with more than 20 years experience , located in Wuhan city , China .
Main products included PD free test set, AC/DC hipot tester, transformer tester, CT/PT analyzer , Circuit breaker tester, relay test set, transformer oil tester ,etc .
Warmly welcome to visit Goldhome Hipot factory !




  • Similar Products
Full Page Contact Supplier