Model NO.:
11KV SC (B) 11
Phase:
Three
Brand:
Jsm
Connection Method:
Yyn0, Dyn11 or Others
Primary Voltage:
11; 10.5; 10; 6.3; 6kv
Frequency:
50 or 60 Hz
Secondary Voltage:
0.4, 0.433kv
Type:
Transformer
Product Description
1) 22 years' manufacturing experience with three subsidiaries
2) Authoritative type test report
3) KPLC's supplier in Kenya
3) IP54
Tech data of 10kv, 11kv SC(B)11 series resin insulation dry-type power transformer
1. Standards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726
2. Voltage Grade: 6, 10, 6.3KV, 11kV
3. Voltage Regukation Mode: Off circuit tap changing; On load tap changing
4. Tapping Range: ± 5%, ± 2× 2.5%, ± 4× 2.5% or others
5. Frequency: 50Hz; 60Hz
6. Phase: Three phase
7. Connection Sign: Yyn0, Dyn11 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
9. Max. Temperature: 120K
10. Cooling Method: ONAN or ONAF
11. Insulation Class: Grade F
Features:
High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. It becomes solid under high temperature. It equipped with high mechanical intensity, low discharge partly; Low voltage coils are wrapped with a whole piece of copper foil, with strong anti-shortcut capacity. The core is made of silicon steel. By reasonable choosing magnetic density, decrease the empty loading loss effectively
Fire protection, anti-explosion, and no pollution
Coil is free from humidity, low noise and well characteristic of heating dispersion
Low loss, energy saving, free from maintenance, small size, light, and easy for installation
2) Authoritative type test report
3) KPLC's supplier in Kenya
3) IP54
Tech data of 10kv, 11kv SC(B)11 series resin insulation dry-type power transformer
1. Standards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726
2. Voltage Grade: 6, 10, 6.3KV, 11kV
3. Voltage Regukation Mode: Off circuit tap changing; On load tap changing
4. Tapping Range: ± 5%, ± 2× 2.5%, ± 4× 2.5% or others
5. Frequency: 50Hz; 60Hz
6. Phase: Three phase
7. Connection Sign: Yyn0, Dyn11 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)
9. Max. Temperature: 120K
10. Cooling Method: ONAN or ONAF
11. Insulation Class: Grade F
Features:
High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. It becomes solid under high temperature. It equipped with high mechanical intensity, low discharge partly; Low voltage coils are wrapped with a whole piece of copper foil, with strong anti-shortcut capacity. The core is made of silicon steel. By reasonable choosing magnetic density, decrease the empty loading loss effectively
Fire protection, anti-explosion, and no pollution
Coil is free from humidity, low noise and well characteristic of heating dispersion
Low loss, energy saving, free from maintenance, small size, light, and easy for installation
| Technical Data of 10kV SC(B)11 Cast Resin F Insulation Class Dry Type Power Transformer | ||||||||||||||
| Loss(kW) | Insulation Level | Weight (kg) | Outline Dimension (mm) | Outline dimension with protective casing | ||||||||||
| Rated Capacity | Voltage Group(kV) | Connection Method | (120) | No-load current | (L) | (W) | (H) | (L) | (W) | (H) | ||||
| (kVA) | HV | LV | No-load | Load | % | |||||||||
| 10 | 0.121 | 0.29 | 3.8 | 130 | 600 | 450 | 490 | 900 | 800 | 850 | ||||
| 20 | 0.153 | 0.565 | 3.3 | 170 | 600 | 450 | 560 | 900 | 800 | 850 | ||||
| 30 | 0.176 | 0.67 | 2.5 | 330 | 620 | 450 | 650 | 1050 | 900 | 1000 | ||||
| 50 | 0.243 | 0.896 | 2 | 380 | 620 | 450 | 750 | 1050 | 900 | 1000 | ||||
| 63 | 0.314 | 1.15 | 2 | 440 | 750 | 500 | 760 | 1050 | 1000 | 1150 | ||||
| 80 | 0.333 | 1.311 | 2 | 510 | 750 | 500 | 760 | 1100 | 1000 | 1150 | ||||
| 100 | 0.36 | 1.492 | 1.9 | 590 | 750 | 500 | 890 | 1150 | 1100 | 1250 | ||||
| 125 | 11 | 0.423 | 1.758 | 1.7 | 650 | 1060 | 600 | 1020 | 1350 | 1050 | 1200 | |||
| 160 | 10.5 | Dyn11 | 0.491 | 2.023 | 1.7 | 780 | 1060 | 600 | 1060 | 1400 | 1050 | 1250 | ||
| 200 | 10 | 0.4 | 0.563 | 2.403 | 1.5 | F/F | 930 | 1060 | 710 | 1120 | 1450 | 1100 | 1350 | |
| 250 | 6.3 | Yyn0 | 0.648 | 2.622 | 1.5 | 1040 | 1100 | 710 | 1140 | 1500 | 1150 | 1400 | ||
| 315 | 6 | 0.792 | 3.297 | 1.3 | 1180 | 1150 | 710 | 1195 | 1500 | 1200 | 1450 | |||
| 400 | 0.878 | 3.791 | 1.3 | 1450 | 1260 | 870 | 1285 | 1600 | 1250 | 1600 | ||||
| 500 | 1.044 | 4.636 | 1.3 | 1630 | 1290 | 870 | 1355 | 1600 | 1300 | 1650 | ||||
| 630 | 1.211 | 5.577 | 1.1 | 1900 | 1450 | 870 | 1420 | 1800 | 1300 | 1700 | ||||
| 630 | 1.117 | 5.662 | 1.1 | 1900 | 1500 | 870 | 1370 | 1850 | 1300 | 1650 | ||||
| 800 | 1.444 | 6.607 | 1.1 | 2290 | 1550 | 870 | 1570 | 1900 | 1300 | 1800 | ||||
| 1000 | 1.593 | 7.724 | 1 | 2700 | 1600 | 870 | 1665 | 1950 | 1300 | 1950 | ||||
| 1250 | 1.881 | 9.206 | 1 | 3130 | 1680 | 1120 | 1765 | 2050 | 1350 | 2000 | ||||
| 1600 | 2.205 | 11.14 | 1 | 3740 | 1750 | 1120 | 1860 | 2100 | 1400 | 2100 | ||||
| 2000 | 2.988 | 13.73 | 0.9 | 4150 | 1770 | 1120 | 1865 | 2150 | 1500 | 2100 | ||||
| 2500 | 3.6 | 16.31 | 0.8 | 4810 | 1870 | 1120 | 1950 | 2200 | 1500 | 2200 | ||||
| 3150 | 4.626 | 21.38 | 0.7 | 5800 | 1950 | 1120 | 1900 | 2350 | 1600 | 2250 | ||||
| 4000 | 5.364 | 25.65 | 0.7 | 7100 | 2100 | 1120 | 2050 | 2400 | 1600 | 2300 | ||||
| (Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz. | ||||||||||||||