Swipe or use the arrows to view product images.
11kv Indoor High Voltage Vacuum Circuit Breaker with Lateral operating Mechanism
| Price | $1500.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shaanxi, China |
| Popularity | 251 people viewed |
Model NO.:
VIB/CX-12 series
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
MCB
Poles Number:
3
Type:
Circuit Breaker
Function:
Circuit-Breaker Failure Protection
Certification:
VDE, ISO9001-2000, CE
Rated Voltage:
11kv
Rated Current:
630/1250/1600A
Rated Frequency:
50Hz
Operating Mechanism:
Lateral
Match Switchpanel Width:
600mm
Trademark:
Longxiang
Transport Package:
Wooden Case for Export Shipment
Specification:
IEC: M2-E2-C2
Origin:
China Baoji
HS Code:
85389000
Product Description
VIB/CX-12 series of Indoor High Voltage Vacuum Circuit Breaker
With Lateral Operating Mechanism
General Description
VIB1/R-12 series of Indorr High Voltage Circuit Breaker With Lateral Operating Mechanism used spring to storage energy.
The operating mechanism can be operated by two ways:by manual and electromotive operation.
The characteristics is accordance with GB1984-2003 High voltage AC Circuit breaker,
JB3855-1996 3.6-4.5kV Indoor AC High Voltage Circuit Breaker and
IEC standard 62271-100:2001 High Voltage AC Circuit Breaker.
Applying ambient conditions
1.Ambient temperature:-15ºC~+40ºC.
2.Ambient humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
3.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
4.The height above sea level:≤1000m
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Following information is required for order
VCB Full type,main technical specification,distance between phase and quantily.
Type and specification of service voltage.
Name and quantity of spare parts.
Welcome for enquiry and factory visit!
With Lateral Operating Mechanism
General Description
VIB1/R-12 series of Indorr High Voltage Circuit Breaker With Lateral Operating Mechanism used spring to storage energy.
The operating mechanism can be operated by two ways:by manual and electromotive operation.
The characteristics is accordance with GB1984-2003 High voltage AC Circuit breaker,
JB3855-1996 3.6-4.5kV Indoor AC High Voltage Circuit Breaker and
IEC standard 62271-100:2001 High Voltage AC Circuit Breaker.
Applying ambient conditions
1.Ambient temperature:-15ºC~+40ºC.
2.Ambient humidity:the average humidity of a day should be no more than 95%; the average humidity of a month should be no more than 90%.
3.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8kPa.
4.The height above sea level:≤1000m
5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Following information is required for order
VCB Full type,main technical specification,distance between phase and quantily.
Type and specification of service voltage.
Name and quantity of spare parts.
Welcome for enquiry and factory visit!
- Similar Products
$2000.00
1 Piece (MOQ)
Air-Blast Load Break Switch-Fuse Combination Apparatus
Zhejiang Beidian Technology Co., Ltd.
$9.90
100 Pieces (MOQ)
MCB Dz47-63 4.5ka 4 Pole 10~63A Small Mini Circuit Breaker
Zhejiang Shanmeng Electric Co., Ltd.