Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

12kv Indoor HV Vacuum Circuit Breaker Switch with Siemens 3AF Operating Mechanism

Price $1100.00
Min Order 1 Piece
Availability In Stock
Shipping From Shaanxi, China
Popularity 518 people viewed
Model NO.:
ZN68-12/630-25
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
High-Speed Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
3
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification:
VDE, ISO9001-2000, CE, CB, CCC
Rated Voltage:
12kv
Rated Current:
630/1250/1600/2000/2500/3150/4000A
Trademark:
Longxiang Electric
Transport Package:
Non-Solid Wooden Case for Export Shipment
Specification:
IEC: M2-E2-C2
Origin:
Baoji, Shaanxi China
HS Code:
8538900000
Product Description
12kV Indoor HV Vacuum Circuit Breaker with Siemens 3AF Operating mechanism
   
General Description

ZN68-12 series of indoor high voltage vacuum circuit breaker is three phase A.C.50(60) Hz  indoor high voltage distribution, strong breaking capability,long life with complete operating functions and convenient maintenance.It is suitable for controlling  and protecting transmission and distribution system such as power generation plant and substation,especially used in the filed 
where it is frequently operated.


This kind of vacuum circuit breaker can be used for fixed switchgears(XGN2 and GGIA), it also can be equipment with truck
used for varies panels like JYN2,KYN1 and KYN49 as well as used for reconstruction for old-fashioned oil switchgear.


Structural characteristics:
1.The operating mechanism is introduced the technique of operating mechanism from Siemens 3AF vacuum circuit breaker,
the operating mechanism is integrated with vacuum circuit breaker, with characteristics of short transmission routes,
less chains and high transmission efficiency.

2.This operating mechanism adopts spring type, it can be operated by AC or DC, also can be operated by manual.

Applying ambient conditions
1.Ambient temperature:-15~+40ºC.
2.The height above sea level:≤1000m(besides the special requirements).
3.Relative humidity:the average humidity of a day should be no more than 95%;
                               the average humidity of a month should be no more than 90%.

4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;
                                              the average pressure of a month should be no more than 1.8kPa.

5.Earthquake intensity:not exceed 8 degrees.
6.It should be installed in the places without fire,explosion,serious filth, chemical erosion and violent vibration.
 
 