Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

16 Channels Lec Display Earthed Power Supply System Residual Current Monitor Protective Relay

Price $200.00
Min Order 1 Piece
Availability In Stock
Shipping From Chongqing, China
Popularity 445 people viewed
Model NO.:
RCM
Theory:
Electromagnetic Relay
Usage:
Residual Current Relay
Phase:
3
Electricity Type:
Ac
Number of Pole:
N/a
Load:
N/a
Protective Characteristics:
Enclosed Relay
Action Principle:
Electromagnetic Type
Size:
Miniature
Type:
Electric Parameter Relay
Voltage Range:
AC110V,AC220V,DC85-270V
Auxiliary Power Supply:
AC/DC 220V AC/DC 110V DC48V
Reference Frequency:
50Hz
Trademark:
Blue Jay
Transport Package:
Carton
Specification:
10*10*10
Origin:
China
Product Description

Blue Jay RCM-IV is a combined monitoring device for earthed power supply systems (TNC-S,TN-S and TT) residual current. It provide max 16 monitor channels, panel mounting design suit for any electrical cabinet. LED screen display various parameters, easy for site engineer diagnosis and Insulation test.

It can optionally be carried out by selected current transformer or temperature sensor for each channel detect parameter and alarm or trip threshold. Multiple RCM-IV can combination with circuit breaker for build MRCD applications, RS485 port can easy submit data to SCADA systems.

Feature

  • Continuous monitoring of residual currents
  • 100 event data recording function, able to record the time of alarm occurrence and fault type
  • Standard RS485 communication interface & MODBUS-RTU protocol
  • Support manual self-check, optional 2-way passive open input.
  • Backlit graphical LED Display
  • Up to 16 measuring channels for residual current or temperature input
  • The residual current monitoring alarm setting range is 300 ~ 1000mA, with minimal adjustment step 1mA.
  • The temperature alarm setting range is 50.0 ~ 100.0C, minimal adjustment step is 0.1°C;
  • With 2 relay outputs, free to configure various protection methods.
  • Building in buzzer to provide sound alarm, automatically jump to the alarm interface when protection occurs
  • Password protection for device setting
  • Easy to install, especially for electrical cabinet

Specification

Power supply85~265Vac/dc
Consumption<5VA
Residual current accuracy1%
Temperature accuracy±2°C
Data refresh rate1sec
Binary inputsPassive node, isolation voltage 2000VAC
Relay outputAC 250V/5A or DC 30V/5A, 2500V optocoupler isolation
Comm portRS485 Modbus-RTU protocol, baud rate up to 19200bps

Others:

Physical dimension96*96*75mm (L*W*H)
Protection classIP20
Weight0.55kg
Working enviorment-10~55°C
Measurement categoryCAT-III, polution grade 2
Insulation capacity> AC 2kV signal - power - output
Reference standardIEC 61000-4-2, class III
IEC 61000-4-3, class III
IEC 61000-4-4, class IV
IEC 61000-4-5, class IV
IEC 61000-4-6, class III
IEC 61000-4-8, class III
IEC 61000-4-11, class III