Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

1mm U Shape Glow Wire Loop for Glow Wire Test

Price $45.00
Min Order 1 Piece
Availability In Stock
Shipping From Guangdong, China
Popularity 341 people viewed
Model NO.:
iec60695
After-sales Service:
Good
Warranty:
One Year
Type:
Flammability Tester
Display:
Digital
Control:
Manual Control
Display:
Digital
Control:
Manual Control
After-Sales Service:
Good
Warranty:
One Year
Type:
Flammability Tester
Length:
4.0 mm +/-0.04mm (Before Bending )
Hole:
1mm/0.5mm
Material:
Chromium
MOQ:
1PCS
Delivery Time:
3-7days
Product Name:
Glow Wire Loop
Usage:
for Glow Wire Test Apparatus
Trademark:
bnd
Transport Package:
Safety Carton Box
Specification:
iec60695
Origin:
China
Product Description
1mm U Shape Glow Wire Loop for Glow Wire Test



Thermo resistance loop/glow wire loop, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a stan­dardized test platelet made of plastic
(or other materials) for a prescribed period of time under precise test condi­tions. The test examines whether the test specimen ignites, whether the flames propagate and whether burning material drips.

 
 
Specification:
1,Glow-wire material: Nickel/Chromium (>77%Ni/20±1%Cr)
2, Diameter: 4,0 mm ± 0,07 mm (before bending)
3, Dimension A: (after bending) see 5.1
 
Characteristics of Resistance:

 
MaterialNickel/Chromium(80/20) Alloy
Diameter of wire4mm Tolerance 0.04mm
Length80mm
Width between terminals36mm
Thermocouple fit0.55hole
ReferenceIEC60695-2-10 Figure 1
 
 
Appliance:
The tip of the glow-wire is then brought smoothly into contact with the test specimen for a duration of 30 s ± 1 s. An approximate rate of approach and withdrawal of 10 mm/s to 25 mm/s has been found to be satisfactory. However, the rate of approach shall be reduced to near zero upon contact to avoid impact forces exceeding 1,05 N. In those cases where the material melts away from the glow-wire, the glow-wire shall not be kept in contact with the test specimen. Following the application time, the glow-wire and the test specimen are slowly separated, avoiding any further heating of the test specimen and any movement of air which might affect the result of the test. The penetration of the tip of the glow-wire into and through the test specimen shall be limited to 7 mm ± 0,5 mm.
 
When forming the glow-wire , care shall be taken to avoid fine cracking at the tip.
 
 NOTE:
 Annealing is a suitable process for prevention of fine cracking at the tip.


 

Our  Advantages :
Company  Profile :Certifications :Factory  Introduction :Plant Warehouse :Cooperative Customers & Brands:
Customer  Reviews :
Product  Packaging :





  • Similar Products
Full Page Contact Supplier