Model NO.:
DCT-11
Application:
Electronic, Instrument, Electricity Meter
Type:
Current Transformer
Phase:
Three
Operation Condition:
Indoor
Usage:
Protection, Measurement, Electricity Meter
Winding Form:
Multilayer Honeycomb Type
Insulating Medium:
Epoxy Resin
Installation:
Busbar Type
Magnetic Circuit Structure:
Combined Type
Voltage Transformation Principle:
Capacitive Type
Accuracy Class:
0.05, 0.1, 0.2
Application Range:
Energy Meter
Max Current:
5A-300A
Current Transformer Ratio:
1:1000, 1:2000, 1:2500
DC Immunity:
DC Immunity
Material:
Nano Crystalline, Ferrite Core
Self Heating Testing:
Pass Self Heating Testing
DC Tolerance:
Good DC Tolerance
Standard:
IEC62052-31
Rosh:
Rosh Compliant
Trademark:
TOPRO
Transport Package:
Carton/ Pallet
Origin:
China
HS Code:
850431
Product Description

TOPRO 100A DC immune Current transformer (DC immune CT) DCT-11 is used in single phase or three phase electricity meters, under the influence quantity with DC and even harmonics in AC current circuit. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.2, Class 0.1.


Product Characteristics

1. It applied for single phase or three phase energy meters.

2. Adopted high quality amorphous alloy and nanocrystalline core, good ratio error and phase error performance.

3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.

4. Encapsulated with epoxy resin with strong insulation ability.

5. DC immune current transformers (DCT) are used in electricity meters, under the influence quantity with DC and       even harmonics in AC current circuit, the accuracy class up to 0.1, Conform to IEC62053-21.

6. Rosh compliance, CE certificated.

 

Product Dimensions

100A DC immune Current transformer DCT-11

                                   Outline dimension

 
 

 

Product Datasheet

 Model

100 A DC immune Current transformer DCT-11

Rated primary current

5 Amps

Maximum primary current (Imax)

100 Amps

Secondary current (Output)

2 mA

Turn ratio

1 : 2500

DC and even harmonics

Current for direct connected meters, Imax/√2 DC error   should be less than ±3% when power factor=1.0, According to IEC 62053-21

Operating temp.

-40° C - 70° C

Storage Temp

-40° C -85° C

Core material

Nano crystalline and Amorphous

Accuracy

0.1 class

ROSH compliance

Yes