3.5kw AC/DC Dummy Rack Mounted Load Bank for Data Center Server Test

Price $275.00
Min Order 1 Piece
Availability In Stock
Shipping From Sichuan, China
Popularity 353 people viewed
Model NO.:
RT3.5KWLB
After-sales Service:
12 Months
Material:
Steel
Type:
Q235 Steel
Structure:
Rack
Warranty:
12 Months
Protection Level:
IP23 Indoor
Voltage:
Customized
Rated Load:
3.5kw
Application:
Data Center/UPS
Customized:
Customized
Surface Treatment:
Powder Coating
Model No.:
Rt3.5kwaclb
Capacity:
3.5kw Resistive Load
Nominal Voltage:
220V AC
Min. Step:
500W/875W
Load Adjust:
MCB(ABB/Schneider Brand) for Step Control
Power Source Input:
Single/Dual
Fan Working Source:
Internal
Protection:
IP23
Cooling:
2 Low Noises, Horizontal Force Air Cooling DC Fans
Liquid Cooling:
Custimizable
Technology:
Expanded Metal Grids Type Insulated by Ceramic Rin
Packing:
Carton+Wrapping Film
Movement:
2 Steel Handles at Panel Side
Element Type:
High Temperature 8020 Ni-Chrome Finned Resistor
Power Connection:
Power Connected at The Rear Side as Following Pict
Trademark:
Rata
Transport Package:
Carton + Wrapping Film
Specification:
3U
Origin:
China
HS Code:
9030899090
Product Description
3.5kW AC/DC dummy Rack Mounted Load Bank 

> Application

IST commissioning in data center & data room. Testing both electrical network (UPS, Diesel generator, etc.) & air conditioning (free cooling, etc.), the rack-mounted load bank is simulating exact electrical & air conditioning impact of servers in the rack cabinet.

> Parameter(3.5kW/AC220V for reference,DC can be supplied too)
 
Product name
220V AC 3.5KW Rack Mounted Load Bank
Model No.
RT3.5KWACLB
Capacity
3.5kW resistive load
Nominal voltage
220V AC
Min. step
500W/875w
Load steps
> 500w,1000w,1000w,1000w
> 875w,876w,1750w
Load adjust
MCB(ABB/Schneider brand) for step control
Power source input
Single/dual
Fan working source
Internal
Protection
IP23
Duty cycle
Continuous
Operation Temp.
0 to 40 ºC
Storage Temp.
0 to 60 ºC
Cooling
2 low noises,horizontal force air cooling DC fans, Installed inside the load bank, powered from the test source. Each fan 186CFM,total 372CFM.
Air flow
Air is sucked in the front and blown out horizontally at the rear.
Technology
Expanded metal grids type insulated by ceramic rings
Packing
Carton+wrapping film
Dimension (L*W*H)
3U
Weight
14kg
Movement
2 steel handles at panel side
Element type
High temperature 8020 Ni-chrome finned resistor
Power connection
Power connected at the rear side as following picture shows
Function options
> High temperature
> Air volume adjust
> CFM display
Power cable
> C13
> 1.5~2m
> 32A water proof 3 in 1 plug: the plug with blue color connected to the external power source,and another three plug with black color connected to the load bank.

> Load bank pictures



> Certificates