Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

30kv/60kv/120kv/200kv/300kv Portable Intelligent Integrated DC High Voltage Generator Hipot Tester

Price $2980.00
Min Order 1 sets
Availability In Stock
Shipping From Hubei, China
Popularity 448 people viewed
Model NO.:
KDZG
After-sales Service:
Yes
Warranty:
1 Year
Max Diameter of Workpiece:
<500mm
Mass Scope of Workpiece:
<900kg
Type:
Universal Testing Machine
Maxcapacity:
<1000KN
Accuracy Grade:
0.5
Load Way:
Electronic Load
Loading Method:
Dynamic Load
Display:
Digital
Control:
Computer Control
Weight:
0-100Kg
Power Source:
AC220V
Oil Cylinder Position:
Under
Power Supply:
Signal Phase AC 50Hz 220V±10%
Customized Support:
OEM, ODM, Obm, Software Reengineering
Temperature:
-10~40ºC
with Capacitance:
Capacitance Od Tested Is Unlimited
Power:
Electronic
Ripple Coefficient:
≤1%
Altitude:
Below 1500m
Voltage Measurement Accuracy:
Digital Display Meter
Trademark:
KDZD
Transport Package:
Wooden Case
Specification:
25*28*40cm
Origin:
Hubei, China
HS Code:
9030332000
Product Description
Product Description

 

Integrated machine
Specifications 
40/3(kV/mA)
60/2(kV/mA)
60/3(kV/mA)
60/5(kV/mA)
80/2(kV/mA)
100/2(kV/mA)
120/2(kV/mA)
120/5(kV/mA)
Technical parameter
Rated voltage (kV)
40
60
60
60
80
100
120
120
Rated current (mA)
3
2
3
5
2
2
2
5
Rated power (W)
120
120
180
300
160
200
240
600
Chassis weight (kg)
7
10.5
10.5
10.5
11
11.2
11.2
11.2
Double pressure weight (kg)
Integrated 2.5
2.7
2.7
2.7
3
3.3
3.3
3.3
Double pressure height (mm)
Integrated 400
400
400
400
400
500
500
500
Voltage measurement accuracy
Digital display meter ± (1.0% reading ± 2 characters)
Current measurement accuracy
Digital display meter ± (1.0% reading ± 2 characters)
Ripple coefficient
≤1%
Voltage stability
Random fluctuation, ≤ 1% when the power supply voltage changes ± 10%
Overload capacity
The no-load voltage can exceed the rated voltage by 10% for the mintes
The maximum charging current is 1.5 times of the rated current
Power supply
Signal phase AC 50Hz 220V±10%
Operation mode
Intermittent use
The maximum continue time is 30 minutes
Working emviroment
temperature:-10~40ºC
Relative humidity : no more than 85% at room temperature of 25ºC(no condensation)
Altitude: below 1500m
With capacitance
Capacitance od tested is unlimited
Load capacity
It can be charged with 1.5 times of rated current
Structural characteritics
Epoxy glass fiber reinforecd plastic electrical insulated double pressure cylinder
Air insulation, no leakage
Feature of opeartion box
High precision 0.75UDC1mA one touch button(precision ≤1.0%)zinc oxide arrester test
The over-voltage protection is set at a glance
An aluminum alloy box is placed at the double pressure of the chassis, and the whole machine can be lifted by one hand
 
Splitter machine
Specifications
200/3
(kV/mA)
200/2
(kV/mA)
250/3(kV/mA)
300/2(kV/mA)
300/5(kV/mA)
400/3(kV/mA)
400/5(kV/mA)
Other levels
Technical parameter
Rated voltage (kV)
200
200
250
300
300
400
400
500~1000KV customized
Rated current (mA)
3
2
3
2
5
3
5
Rated power (W)
400
1000
750
600
1500
1200
2000
Chassis weight (kg)
4.5
4.5
4.5
4.5
5.5
5.5
5.8
Double pressure weight (kg)
11.5
11.5
13
16
16
22
22
Double pressure height (mm)
965
965
1030
1250
1250
1900
1900
Voltage measurement accuracy
Digital display meter ± (1.0% reading ± 2 characters)
Current measurement accuracy
Digital display meter ± (1.0% reading ± 2 characters)
Ripple coefficient
≤1%
Voltage stability
Random fluctuation, ≤ 1% when the power supply voltage changes ± 10%
Overload capacity
The no-load voltage can exceed the rated voltage by 10% for the mintes
The maximum charging current is 1.5 times of the rated current
Power supply
Signal phase AC 50Hz 220V±10%
Operation mode
Intermittent use
The maximum continue time is 30 minutes
Working emviroment
temperature:-10~40ºC
Relative humidity : no more than 85% at room temperature of 25ºC(no condensation)
Altitude: below 1500m
With capacitance
Capacitance od tested is unlimited
Load capacity
It can be charged with 1.5 times of rated current
Structural characteritics
Epoxy fiberglass electrical insulation pressure doubling cylinder
Air insulation, no leakage
Feature of opeartion box
High precision 0.75UDC1mA one touch button(precision ≤1.0%)zinc oxide arrester test
The over-voltage protection is set at a glance
The control box is small and convenient for on-site use
 
 
  • Similar Products