Reliable Medium Voltage Fuse with Current Limiting and Arc Extinguishing
Beierbian Group Co., Ltd
Swipe or use the arrows to view product images.
33kv 200A D Poecelain Drop out Fuse Cutout Switch Mounting Assembly
| Price | $50.00 |
|---|---|
| Min Order | 100 Pieces |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 481 people viewed |
Model NO.:
YNC2-33A
Breaking Capacity:
High
Type:
Current Fuse
Usage:
High Voltage
Shape:
Dropout
Fusing Speed:
K
Fusing Device:
Fuse Element
Rated Voltage:
33kv-38kv
Trademark:
YN
Transport Package:
Carton&Pallet or Wooden Case
Specification:
100A/200A
Origin:
China
HS Code:
85351000
Product Description
33kv 200A D Poecelain Drop out Fuse Cutout Switch Mounting Assembly
Drop-out fuse cutout and load switching fuse cutout are of outdoor used high voltage protective device. To be connected with incoming feeder of distribution transformer or distribution lines, it mainly protect transformer or lines from short circuit and overload, and on/off loading, current. Drop-out fuse cutout is composed of insulate insulator supports and fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of inside arc-extinguishing tube. Outer phenolic compound paper tube or epoxy glass tube, load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure switching on-off loading current.
At normally working via fuse link tightened the fuse tube is fixed to form up of close position. In case system occur faults, fault current result result in fuse melt immediately and take piece electric are, which let arc-extinguishing tube being heated and explode a lot of gas, This will produce high pressure and below of the are along with tube. After fuse link melt moving contact has no tightened strength again, mechanism is locked and fuse tube drop out, Cutout now is in open position. When it needs to switch off during cutout loading, operator shall via insulating operating bar pull the moving contact, at its beginning main contact and auxiliary static contact is contacted still, Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.
Main Technical Parametes
| Type | Rated voltage (kv) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Powerfrequency withstand voltage | Leakage distance (MM) | Weight (KG) | Dimension (CM) |
| YNC2-33A/100 | 30-33 | 100 | 8000 | 170 | 70 | 660 | 12 | 59*36*12.5 |
| YNC2-33A/200 | 30-33 | 200 | 10000 | 170 | 700 | 660 | 12 |
- Similar Products
$0.03
1000 piece (MOQ)
T1a 250V Round Type Slow Blow Time Lag Micro Square Fuse
Shenzhen Cozy Electronics Co.,Ltd.
$0.82
100 Pieces (MOQ)
Gd-10PV-32A Low Voltage DC Fuse Core
Gandian Lightning Protection Electric Co., Ltd.
Negotiable
20 Pieces (MOQ)
Ad30 22X58 Cylindrical Fuse 440V
ZHEJIANG FUERZI ELECTRIC TECHNOLOGY CO., LTD.