Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

36kv Cable Accessories Cold Shrinkable Indoor Cable Termination

Price $180.00
Min Order 1 Set
Availability In Stock
Shipping From Chongqing, China
Popularity 269 people viewed
Model NO.:
HCLN-36
Type:
Cold Shrink
Material:
Silicone Rubber
Application:
Insulation Protection
Character:
Insulation
Species:
Terminal
Production Process:
Cold Pressing
Shape:
Rectangular
Certification:
ISO, IEC, GB
Brand:
Hifuture
Cross Section:
50-630 Sq.M.
Core:
Single-Core, Three-Core
Lug Type:
Cu, Al, Cual
Features:
Excellent Insulation, Anti-Tracking, etc
Trademark:
HiFuture
Transport Package:
1 Set/ Carton
Specification:
12kV, 24kV, 36kV
Origin:
Shenzhen, China
HS Code:
8538900000
Product Description
36kV cold shrinkable indoor cable termination


Cold Shrink Cable Accessories: 
1. Hifuture cold shrinkable cable accessories adopt world renowned brand liquid/solid silicone rubber material. The products are with excellent insulation, anti-tracking, rebound resistance, heat/cold resistance, ozone resistance, anti-aging, and good dielectric properties, and can be used under various harsh conditions.

2. Geometric stress control method.

3. Standards compliance: IEC60502, GB/T12706.4, EN50180& EN50181(C type bushing)

4. Cold installation, easy and safe without using fire, just by pulling the spiral.


Technical Data:
Rated Voltage8.7/15(17.5)kV12/20(24)kV18/30(36)kV26/35(40.5)kV
Running Temperature17.5kV24kV36kV40.5kV
AC Withstand Voltage and DC Withstand Voltage39kV, 5min or 35kV, 15min, no flashover, no breakdown54kV,5min, or 48kV, 15min, no flashover, no breakdown81kV, 5min, or 72kV, 15min, no flashover, no breakdown117kV, 5min or 104kV, 15 min no flashover, no breakdown
Partial Discharge15kV, PD≤5pC20kV, PD≤5pC30kV, PD≤5pC45kV, PD≤5pC
Impulse Voltage Test95kV, ±10 times125kV, ±10 times170kV, ±10 times200kV, ±10 times
Short Circuit Thermal Stability (Conductor)24kA, 2s twice, no visible damage25kA, 2s twice, no visible damage23kA, 2s twice, no visible damage25kA, 2s twice, no visible damage
Short Circuit Dynamic Stability83kA, not less than 10ms, no visible damage63kA, not less than 10ms, no visible damage83kA, not less than 10ms, no visible damage88kA, not less than 10ms, no visible damage
Constant Voltage Load Cycleapply voltage 1.25U0 to conductor and heat to(90-95)ºC heat for 5h and cool for 3h, total 3 times
Salt Spray Test1.25U0 1000h, no flashover, no breakdown, trip not more than 3 times, no obvious damage
Humidity Test1.25U0 300h, no flashover, no breakdown, trip not more than 3 times, no obvious damage
Long-time Running Temperature-40ºC to 95ºC
Short Circuit Temperature250ºC, lasting time less than 5s
Cable Accessories Conductor Materialcopper, aluminum, copper&aluminum