Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

4H2O2-5 Hydrogen Peroxide Electrochemical Sensor

Price $68.70
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 371 people viewed
Model NO.:
4H2O2-5
Type:
Infrared Gas Sensor
Conductivity Type:
Surface Type
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Plastic
IP Rating:
IP65
Sensitivity:
Medium
Certification:
RoHS
Customized:
Customized
Operating Principle:
3-Electrode Electrochemical
Detection Range:
0~5 Ppm
Response Time (T90):
<60 S
Repeatability:
<±2% Signal
LinearityTlinear:
Linear
Long Term Output Drift:
<2% Signal/Month
Trademark:
AERI
Transport Package:
Packing Bottle
Specification:
30 ml
Origin:
China
HS Code:
4204960212
Product Description
4H2O2-5 Hydrogen Peroxide Electrochemical Sensor 
(P/N: SEC-4H2O2-5)

 
 
Technical Specifications 
MEASUREMENT  
Operating Principle3-electrode electrochemical 
Detection Range0~5 ppm 
Sensitivity2000 ± 1000 nA /ppm 
Response Time (T90)<60 s 
Repeatability<±2% signal 
LinearityLinear 
Long term output Drift<2% signal/month 

ELECTRICAL
  
Resolution0.05 ppm 
Recommended Load5~30  
Bias Voltage300 mV 
 0 mV
ENVIRONMENTAL  
Operating Temp. Range-20°C ~ 40°C 
Operating Humidity Range15% RH ~ 90% RH non-condensing 
Operating Pressure Range800 ~ 1200 mbar 

LIFETIME
  
Recommended Storage Temp.0°C to +20°C in sealed container 
Expected Operating Life24 months in air 
Storage Life6 months in original packaging 
Standard Warranty18 months from date of dispatch 

Product Dimensions 

All dimensions in millimeters (± 0.1mm)
 

Cross-sensitivity Data
GasConcentration(ppm)Output signal
(ppm H2O2 equivalent)
Carbon Monoxide200.3
Nitric Oxide20-0.5
Sulfur Dioxide21.5
Methane50000
Sensors may behave differently with changes in ambient conditions and any batch may show significant variation from the values quoted.

SAFETY NOTE
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale
  • Similar Products
Full Page Contact Supplier