Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

4pocl3-100 Phosphorus Oxychloride Electrochemical Sensor

Price $68.70
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 250 people viewed
Model NO.:
4POCl3-100
Type:
Electrochemical Gas Sensor
Conductivity Type:
Surface Type
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Plastic
IP Rating:
IP65
Sensitivity:
Medium
Certification:
RoHS
Customized:
Customized
Operating Principle:
3-Electrode Electrochemical
Detection Range:
0~100 Ppm
Response Time (T90):
≤60 S
Repeatability:
<±2% Signal
Linearity:
Linear
Measurement:
<2% Signal/Month
Trademark:
AERI
Transport Package:
Packing Bottle
Specification:
30 ml
Origin:
China
HS Code:
4204960212
Product Description
4POCl3-100 Phosphorus oxychloride Electrochemical Sensor 
(P/N: SEC-4POCl3-100 )

 
 
Technical Specifications
MEASUREMENT 
Operating Principle
  1. Electrode
electrochemical
Detection Range0~100 ppm
Sensitivity100± 50nA/ppm
Response Time (T90)60 s 
Repeatability<±2% signal
LinearityLinear
MEASUREMENT <2% signal/month

ELECTRICAL
Resolution0.1 ppm
Recommended Load5~35 
Bias Voltage0mV

ENVIRONMENTAL
Operating Temp. Range-20°C ~ 50°C
Operating Humidity Range15% RH ~ 90% RH non- condensing
Operating Pressure Range800 ~ 1200 mbar

LIFETIME
Recommended Storage Temp.0°C to +20°C in sealed container
Expected Operating Life24 months in air
Storage Life6 months in original packaging
Standard Warranty12 months from date of despatch

Product Dimensions

All dimensions in millimeters (± 0.1mm)
 




Cross-sensitivity Data
GasConcentration(ppm)Output signal
(ppm POCl3 Styrene equivalent)
Hydrogen1000
Sulfur dioxide50100
Carbon dioxide20000
Carbon monoxide500
Whilst the Gas Sensor are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react. The cross-sensitivity values quoted are based on tests conducted on a small number of sensors. They are intended to indicate sensor response to gases other than the target gas. Sensors may behave differently with changes in ambient conditions and any batch may show significant variation from the values quoted.
SAFETY NOTE:
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
If the Gas Sensor is removed from application circuit, a jumper should be added on 'R' and 'S' pin.
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale.