Swipe or use the arrows to view product images.
60Hz Dx Vertical / Horizontal Air to Air Ducted Split Air Handling Unit with Pre/Medium/HEPA Filter Ahu
| Price | $18988.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shandong, China |
| Popularity | 413 people viewed |
Model NO.:
AA
Type:
Chiller
Air Tube Material:
Galvanized Sheet
Corrosion Durability:
General
Operating Voltage:
380-415, 440, 460, 50/60Hz
Noise Level:
Ordinary
Application Fields:
Supermarket, Hospital, Pharmaceutical and Building
Mounting:
Split
Lifetime:
15~20 years
Certification:
ISO, CE
Condition:
New
Compressor:
Copeland/Pansonic Brand
Electric Parts:
World Famous Brand
Usage:
Commercial/Industrial
Cooling:
Cooling Only or Heat Pump
Refrigerant:
R22/R407c/R410A/R134A
Filter Type:
Pre, Medium and HEPA(Optional)
Indoor Unit:
Vertical and Horizontal Use
Trademark:
AMRTA or OEM
Transport Package:
Standard Package Fit for Transportation
Specification:
Color: white
Origin:
China
HS Code:
8418612090
Product Description
60Hz DX Vertical / Horizontal Air to Air Ducted Split Air Handling Unit with Pre/Medium/HEPA Filter AHU
Cooling capacity 20kW ~ 104kW
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.
Split installation, connected by means of flare/welding coupling.
Easy operation line controller:
Multi safety protection
Additional electric heater on indoor unit
Additional heating coil on indoor unit
TECHNICAL DATA
Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
**** Optional as request.
Unit Pictures
Some Overseas Simple Projects
Our Products Range
Contact Information
Anne
----------------------------------------------------------------------------------
JINAN AMRTA AIR CONDITIONING CO.,LTD
Website: jinanamrtaac.en.made-in-china.comjinanamrtaac.en.made-in-china.com
Cooling capacity 20kW ~ 104kW
Product Description
11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.
Split installation, connected by means of flare/welding coupling.
Easy operation line controller:
- Cooling/Heating/Fan/Auto
- Timing On/Off
- Error indication
Multi safety protection
- High/low pressure protection
- Time delay and antifreeze switch
- Phase sequence relay
- Current overload protection
- Overheat protection
Additional electric heater on indoor unit
Additional heating coil on indoor unit
TECHNICAL DATA
| Mod. | 20 | 25 | 32 | 36 | 42 | 48 | ||
| Nominal cooling capacity* | kW | 19.5 | 24.8 | 31.2 | 35.6 | 41.3 | 47.4 | |
| Nominal heating capacity** | kW | 22.6 | 28.9 | 35.8 | 40.8 | 46.9 | 54.4 | |
| Connection | ||||||||
| Method | / | Flare | Flare | Flare | Welding | Welding | Welding | |
| Liquid pipe diameter | ¢mm | 9.52x2 | 12.7x2 | 12.7x2 | 15.88x1 | 15.88/12.7 | 15.88/12.7 | |
| Gas pipe diameter | ¢mm | 15.88x2 | 19.05x2 | 19.05x2 | 28x1 | 28/19.05 | 28/19.05 | |
| Power supply | / | 230V/3N/60Hz | ||||||
| OUTDOOR UNIT | Compressor | |||||||
| Qty/refrigerant circuit | Nr. | 2/2 | 2/2 | 2/2 | 1/1 | 2/2 | 2/2 | |
| Cooling power input* | kW | 7.2 | 9.3 | 11.8 | 12.8 | 15.1 | 17.9 | |
| Heating power input** | kW | 7.13 | 9.21 | 11.68 | 12.67 | 14.95 | 17.72 | |
| Energy adjustment | % | 50-100 | 50-100 | 50-100 | 0-100 | 40-60-100 | 33-66-100 | |
| Axial fans | ||||||||
| Quantity | Nr. | 1 | 1 | 1 | 1 | 2 | 2 | |
| Airflow | m3/h | 9400 | 9400 | 12500 | 14200 | 18800 | 18800 | |
| Sound pressure level*** | dB(A) | 67 | 67 | 68 | 70 | 71 | 71 | |
| Net weight | kg | 170 | 180 | 220 | 280 | 260 | 280 | |
| INDOOR UNIT | Centrifugal fans | |||||||
| Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | 2 | |
| Airflow | m3/h | 3500 | 4500 | 5650 | 6450 | 7400 | 8550 | |
| ESP | Pa | 120 | 100 | 150 | 130 | 180 | 200 | |
| Sound pressure level*** | dB(A) | 64 | 64 | 66 | 66 | 68 | 68 | |
| Net weight | kg | 90 | 100 | 150 | 160 | 180 | 200 | |
| Additional electric heater**** | kW | 2×3 | 2×4 | 2×5 | 2×6 | 2×6 | 2×8 | |
| Additional heating coil**** | kW | 22.2 | 28.4 | 35.1 | 40.0 | 46.0 | 53.3 | |
| Mod | 52 | 62 | 72 | 88 | 104 | ||
| Nominal cooling capacity* | kW | 51.3 | 63.3 | 71.3 | 87.9 | 103.7 | |
| Nominal heating capacity** | kW | 58.9 | 72.6 | 81.9 | 100.0 | 115.8 | |
| Connection | |||||||
| Method | / | Welding | Welding | Welding | Welding | Welding | |
| Liquid pipe diameter | ¢mm | 15.88/12.7 | 15.88×2 | 15.88×2 | 15.88×2 | 19.05×2 | |
| Gas pipe diameter | ¢mm | 28/19.05 | 28×2 | 28×2 | 28×2 | 35×2 | |
| Power supply | / | 230V/3N/60Hz | |||||
| OUTDOOR UNIT | Compressor | ||||||
| Qty/refrigerant circuit | Nr. | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | |
| Cooling power input* | kW | 18.4 | 23.1 | 26.6 | 28.1 | 39.3 | |
| Heating power input** | kW | 18.22 | 22.87 | 26.33 | 27.82 | 38.91 | |
| Energy adjustment | % | 30-70-100 | 50-100 | 50-100 | 50-100 | 50-100 | |
| Axial fans | |||||||
| Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | |
| Airflow | m3/h | 21500 | 26500 | 29880 | 36500 | 43500 | |
| Sound pressure level*** | dB(A) | 71 | 71 | 71 | 71 | 71 | |
| Net weight | kg | 330 | 460 | 460 | 780 | 800 | |
| INDOOR UNIT | Centrifugal fans | ||||||
| Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | |
| Airflow | m3/h | 9250 | 11450 | 12900 | 14800 | 17100 | |
| ESP | Pa | 200 | 300 | 300 | 280 | 500 | |
| Sound pressure level*** | dB(A) | 68 | 68 | 69 | 69 | 70 | |
| Net weight | kg | 220 | 230 | 300 | 320 | 400 | |
| Additional electric heater**** | kW | 2×8 | 2×10 | 2×10 | 2×12 | 2×14 | |
| Additional heating coil**** | kW | 57.8 | 71.2 | 80.3 | 98.0 | 113.5 | |
Performance values refer to the following conditions:
* Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.
** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C.
*** Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
**** Optional as request.
Unit Pictures
Some Overseas Simple Projects
Our Products Range
Contact Information
Anne
----------------------------------------------------------------------------------
JINAN AMRTA AIR CONDITIONING CO.,LTD
Website: jinanamrtaac.en.made-in-china.comjinanamrtaac.en.made-in-china.com
- Similar Products
$1100.00
5 Pieces (MOQ)
3.5kw Split Air Conditioner for Ict Rack Cooling
DBS Cooling Technology (Suzhou) Co., Ltd.
$1150.00
1 Piece (MOQ)
24000 BTU Portable Air Conditioner Spot Cooler Wmac24 Hot Seller
XIAMEN WINMORE TRADE CO., LTD.
$225.00
5 Pieces (MOQ)
1100W 117L Desert Coolers Portable Outdoor Industrial Air Coolers
Abeite New Material Co., Ltd.