Model NO.:
hmcot
After-sales Service:
Life Time Support
Warranty:
1 Year or Extended
Type:
Vlf Hipot Tester
Accuracy Grade:
0.5
Load Way:
Electronic Load
Loading Method:
Capacitive Load
Display:
LCD
Control:
Computer Control
Weight:
5kgs
Power Source:
AC220V
Output Frequency:
0.1Hz, 0.05Hz, 0.02Hz
Stability of Frequency:
Fluctuation < 0.5%
Measurement Accuracy:
+-3%
Positive and Negative Voltage Peak Error:
<=3%
Voltage Waveform Distortion:
<=5%
Product Name:
Vlf Hipot Tester
Test Voltage Range:
30kv/40kv/50kv/60kv/70kv/80kv
Standard:
IEC
Certificate:
CE, ISO, SGS
Language:
English
Model:
Vlf Hipot Tester with Tan Delta Measuring
Input Voltage:
220V or 120V
Frequency:
50Hz/60Hz
Function1:
Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring
Function 2:
Partial Discharge Detect
Trademark:
HMDQ
Transport Package:
Wooden Box with Foam Inside
Specification:
according to specification
Origin:
Hubei, China(Mainland)
HS Code:
9022909090
Product Description

60kv 80kv 90kv vlf cable hipot test equipment with tan delat measuring and pd diagnostics
 
Packaging Details: standard package for VLF hipot tester with tan delta measurement 40kV/60kV/80kV vlf high voltage generator cable testing equipment                                   
Delivery Detail:vlf ac hipot tester 7-15days after order confirmed


I. High Voltage Test Equipment Introduction
VLF hipot tester adopts digital frequency conversion technology, single-chip microcomputer control, and the step-up, step-down, measurement and protection are fully automated. Due to full electronization, it has small volume and light weight. It adopts large screen color touch screen, which is clear and intuitive, simple to operate and display output waveform. It can carry out AC withstand voltage test  and Dielectric loss(tgδ) measurement  for high voltage power cable


II. High Voltage Test Equipment Feature:

1) single connection structure (one booster) shall be adopted for ultra-low frequency with rated voltage less than or equal to 50kV; The ultra-low frequency greater than 50kV adopts series structure (two boosters are connected in series), which greatly reduces the overall weight and enhances the load capacity. Moreover, both boosters can be used alone to achieve multi-purpose of one machine.

 

3)Current and voltage data are directly sampled from the high voltage side, so the data is accurate.

 

4)Intelligent comprehensive protection function: there is no need to set the current and voltage protection value. The instrument can calculate the overvoltage and overcurrent protection value according to the capacitance of the test object and the test voltage value. It can also protect the sudden change of voltage and current, so it can capture the discharge. The protection action time is less than 20ms.

 

5)High voltage cable 150KV is adopted for output, which is safe and reliable.

 

6) Since the closed-loop negative feedback control circuit is adopted, the output has no capacity rise effect.

 

7) Dielectric loss(tgδ) measurement function (for buyer's option), which can measure the dielectric loss, capacitance and insulation resistance of the test object at the same time.


 III. structure image:


IV. Main Parameter:

1) Rated output voltage: 30kv-80kv, details see Table 1

2)Output frequency: automatic frequency conversion, range: 0.1Hz-0.01Hz

3)carrying capacity: see Table 1

4)Measurement accuracy: ≤ 3%

5)Voltage positive and negative peak error: ≤ 3%

6)Voltage waveform distortion: ≤ 3%

7)Operating conditions: indoor and outdoor; Temperature: - 10 ºC - + 40 ºC;

Humidity: ≤ 85% RH

8) Input power supply: 220V ± 5%, 50Hz/60Hz. If the micro generator is used for power supply, the frequency conversion generator shall be used instead of the ordinary generator, because the unstable speed of the ordinary generator will make the boost abnormal and damage the instrument.


V. FAQ
 

 1.Can you provide the training for us?

Yes, we can provide free training for our client at our factory.

If you require the training on-site, we also can arrange accordingly.

We have 10 seasoned engineers who become our technical team, they flied many countries for client's installation and commissioning!

 

2.What is your after-sale service

We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.

 

3.What's the warranty period ?

Our warranty period is one year .

The product can be replaced within 1 month, can be repaired for free charge  for one year and maintenance for lifetime.

What is more, our warranty can be extended only charged small warranty fee.


VI.Similar product: 




VII. Company information

Wuhan Goldhome Hipot Electrical Co.,ltd is an ISO certified factory specially in  manufacture electric test equipment with more than 20 years experience , located in Wuhan city , China .
Main products included PD free test set, AC/DC hipot tester, transformer tester, CT/PT analyzer , Circuit breaker tester, relay test set, transformer oil tester ,etc .
Warmly welcome to visit Goldhome Hipot factory !








  • Similar Products
Full Page Contact Supplier