$13.00
50 Pieces (MOQ)
DC Surge Protection Device 1000V 40ka SPD for Solar System
Wenzhou Leeyee Electric Co., Ltd.
Swipe or use the arrows to view product images.
66kv Aereal Fault Indicator with Portable Remote Controlwith Remote Terminal Communication Unit with Vitual Management Platform
| Price | $60.00 |
|---|---|
| Min Order | 100 Pieces |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 388 people viewed |
Model NO.:
ESI
Trademark:
HEMG
Transport Package:
Wooden/Carton
Specification:
6-66KV
Origin:
China
Product Description
WITH PORTABLE REMOTE CONTROL
WITH REMOTE TERMINAL COMMUNICATION UNIT
WITH VITUAL MANAGEMENT PLATFORM
| FAILURE INDICATORS FOR AEREAL LINES 6-66 KV | ||||
| Nº | DESCRIPCION | UNIDAD | REQUERIDO | GARANTIZADO |
| I. | MEDIUM VOLTAGE FAILURE INDICATORS | |||
| 1.0 | Country of origin | Indicate | CHINA | |
| 2.0 | Maker | HEMG | ||
| 3.0 | Model | ESI | ||
| 4.0 | Manufacturing Standard and Testing | ANSI/IEEE 495: 2007 | ANSI/IEEE 495:2007 | |
| 5.0 | Type of Installation | Exterior | OUTDOOR | |
| 6.0 | Opening System | Monofásico | SINLE SYSTEM | |
| 7.0 | Type of operation | Automática y manual | AUTOMATION AND MANUAL | |
| 8.0 | Installation Altitude | m.s.n.m. | Hasta 4500 | 4500 |
| 9.0 | Operating range (system voltages) | kV | 7 - 66 | 7-66 |
| 10.0 | Operating range (system currents) | Amp | 1 - 600 | 1-600 |
| 11.0 | Operating Frequency | Hz | 60 | 60/50HZ |
| 12.0 | Operating temperature | ºC | -40 a +85 | (-40 TO 85) |
| 13.0 | IP Protection Index | IP67 | IP67 | |
| 14.0 | Terms of Use | Continuo | CONTINUOUS | |
| - Signal Type Signal | Luminosa: Estroboscópica de alta densidad | BRIGHT | ||
| - Angle of visibility | Grados | 360 | 360 | |
| - Continuous display time | horas | ≥ 700 | >=700 | |
| - Indicator life | años | ≥ 10 | 10 | |
| - weight | kg | ≤ 1 | 0.75 | |
| 15.0 | Indication, minimum visibility distance during sunny day | m | 100 | 100 |
| 16.0 | Identification of Transient and Permanent Failure | Obligatorio | YES.COMPLAY | |
| 17.0 | Conductor section range | mm² | 25 a 240 | 25 TO 240 |
| Short-term current | KA | 25 | 25 | |
| 18.0 | Current Sensor | |||
| - Model | CT | |||
| - Precision | Indicar | (+/-3%) | ||
| 19.0 | Voltage sensor | |||
| - Model | BY CT | |||
| Indicar | SELF-SUITABLE | |||
| 20.0 | Auxiliary Power System - Signal | |||
| - Internal Battery | Litio | Lithium | ||
| - Rated Voltage | Vdc | Indicar | 3.6V | |
| - Useful life | años | ≥ 10 | 10 | |
| 21.0 | Programmable Parameters for Performance | |||
| - Trip current range for the indication of the short-circuit current. | Corriente de disparo: Rango de programación de corriente para la indicación de cortocircuito: Desde 10 hasta 1500 A. | YES.COMPLAY | ||
| Corriente de disparo: Autoajustable para fallas a tierra: 5 A a 100A (paso de 5 A) | YES.COMPLAY | |||
| - Inrush current lock | Si | YES.COMPLAY | ||
| - Transient fault indication time | Si, indicar | <=40MS | ||
| - Permanent fault indication time | Si, indicar | 4/8/12/24 HOURS OPTIONAL | ||
| - Flash Interval | Si, indicar | 5S | ||
| - Flash duration | Si, indicar | >=50MS | ||
| - Replacement by Current | Si | YES.COMPLAY | ||
| - Replacement by Voltage | Si | YES.COMPLAY | ||
| - Manual Reset | Si | YES.COMPLAY | ||
| - Remote Reset | Si | YES.COMPLAY | ||
| 22.0 | Metal parts exposed to the weathering of the fault indicator shall be hot dip galvanized in accordance with ASTM A153 | Sí | YES.COMPLAY | |
| 23.0 | Accessories for Fault Indicator Assembly | |||
| -Monitor for the validation of the operation of the Fault Indicator | Sí | YES.COMPLAY | ||
| II. | FAULT INDICATOR COMMUNICATION SYSTEM | |||
| 1.0 | Wireless Local Communication between the Fault Indicator and a physical interface to external RTU or directly to external RTU that acts as a local hub | Sí | YES.COMPLAY | |
| 2.0 | Bidirectional communication between fault indicator and physical interface to external RTU or directly to external RTU | Sí, Indicar la distancia máxima posible de comunicación "bidireccional" que ofrece | YES,MAX 50M | |
| 3.0 | Medium of "local communication" | -Indicar medio y características técnicas (Radio frecuencia, Bluetooth, otro medio) -Indicar la frecuencia de trabajo del Indicador de Falla, si es Libre o licenciada. | YES,RADIO FREQUENCY/433MHZ,FREE | |
| 4.0 | - Minimum sending signals of the fault indicator by local communication to the RTU that acts as a local hub | |||
| Transient failure | Si | YES | ||
| Permanent failure | Si | YES | ||
| Absence of Tension | Si | YES | ||
| Presence of Voltage | Si | YES | ||
| Line Current Measurement | Si | YES | ||
| Measurement of Voltage | Opcional | YES FOR BATTERY | ||
| III | REMOTE TERMINAL UNIT (RTU) | |||
| 1.0 | Manufacturing and Testing Standard | IEC 61326-1, EN 55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8 | IEC 61326-1, EN 55022, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8 | |
| 2.0 | Powered by battery embedded in the RTU | Sí | YES | |
| 3.0 | Battery Type | Primary cells Lithium Thionyl Chloride (LiSOCl2) | YES | |
| 4.0 | Battery life | Años | 10 | 10 |
| 5.0 | Embedded GPRS Modem | Sí | YES | |
| 6.0 | Real-time synchronization (RTC) | Sí | YES | |
| 7.0 | Type of SIM card, provided by the User. | Sim Card (Indicar tipo NanoSIM o microSIM) | SIM CARD | |
| 8.0 | Degree of protection | IP66 | IP66 | |
| 9.0 | Minimum number of digital inputs for fault indicators | 12 | 12 | |
| 10.0 | Allows remote configuration of fault indicator | Sí, herramienta para la validación del funcionamiento | YES | |
| 11.0 | Permanent dispatch capacity to the SCADA of the Companies of the Distriluz Group; Directly or through the virtual platform of management of all the data received from the fault indicator | Si, indicar sí es posible el envío directamente o a través de la plataforma virtual | YES,POSSIBLE BY DIRECTLY OR BY VIRTUAL PLATEFORM | |
| 12.0 | Ability to store latest faults | >= 10 | Si | 10 |
| 13.0 | Mounting Accessories | |||
| - Boxes with clamps for mounting in post of concentrators according to the manufacturer's recommendations. | Si | YES | ||
| IV | REMOTE CONTROL OF FAULT INDICATORS (1) | |||
| 1.0 | Allows you to make configuration settings in the Field Fault Indicator | Sí | YES | |
| 2.0 | Stores settings to be applied in the field | Sí | YES | |
| 3.0 | Allows you to download equipment configurations in the field | Sí | YES | |
| 4.0 | Connects to a PC to download stored data | Opcional | NO | |
| V | VIRTUAL INFORMATION MANAGEMENT PLATFORM | |||
| 1.0 | CPU and monitor for implementation in the control center | Sí/No (2) | YES | |
| 2.0 | Management Software for windows 8 or higher operating system | Sí | YES | |
| 3.0 | Includes Unlimited Software Management License and its update for a minimum period of 10 years. | Sí | YES | |
| 4.0 | Communication interface with the SCADA of the companies of the Distriluz Group | Sí | YES | |
| 5.0 | Allows user and password access | Sí | YES | |
| 6.0 | Configurable environment by the User | Sí | YES | |
| 7.0 | Set of sound and visual alarms (mimic diagram) | Sí | YES | |
| 8.0 | Allows the configuration of alerts via Email and SMS | Sí | YES | |
| Allows the download of information stored in EXCEL format | Sí | YES | ||