AC SPD 1P+N 10-20KA 20-40KA 230V House Surge Protector Protective Low-voltage Arrester Device

Price $7.50
Min Order 60 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 413 people viewed
Model NO.:
TMSPD1
Type:
Power Source Arrester
Structure:
Valve Type Arrester
Installation:
Parallel Arrester
Application:
AC/DC System
Size:
Small
Operation Voltage:
Low Voltage
Shape:
Cuboid
Material:
ZnO
Certification:
ISO9001
Brand:
Timelec
Uc:
230V
In:
20kA
Imax:
40kA
Up:
1.5kV
IEC:
IEC61643-11
IP:
IP20
Protection:
Class II, T2
Trademark:
Timelec, OEM / Private Label brands
Transport Package:
Carton Box
Specification:
36*69*91mm
Origin:
China
HS Code:
853620
Product Description
Product Description

Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.
 

Products features
1. 1P+Nphase protection for AC/Dc system

2. Pluggable module, easy for installation and maintenance

3. High discharge capacity, quick response

4. Double thermal disconnection devices, providing more reliable protection

5. Green window will change when fault and also provide remote alarm control at the same time


A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

According to the National Electrical Manufacturers Association, the average home has $15,000 worth of equipment that can be damaged by surges.

Common Causes of Surge:
It is estimated that 80% of surges are caused by internal sources

Internal Sources:

  • Large appliances turning on / off
  • Faulty wiring or loose connections
  • Overloaded circuits, short circuits, or ground faults
  • Power recovery

External Sources:

  • Lightning
  • Damage to power lines
  • Utility power grid switching


NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1:
Permanently connected Surge Protective Device.  Protects against external and internal surges. May be installed inside or outside the home.

Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.

Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.

Use Type 1, 2, and 3 SPDs for the best level of protection.  
 

Product Parameters
Product categorySurge protection
Product typeSURGE PROTECTIVE DEVICE
Product modelHLSPD,SPD,TMSPD2
Unique selling proposition·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical dataType of SPD according to EN 61643-11Type 2
SPD according to IEC 61643-1Class II
Nominal a.c voltage( Un)230V
Max continuous operating a.c voltage (Uc)275/320/385/440V
Nominal discharge current (In 8/20|jS)10/20KA
Max. discharge current (Imax 8/20pS)20/40KA
Voltage protection level (Up)<1.3/1.4/1.5/1.8/2.2KV
Response time (tA)<25ns
Operating temperature range (Tu)-40°C +80°C
Operating state/fault indicationGreen/red
Cross-section area (min)4mm²
Cross-section area (Max)16mm²
For mounting on35mm DIN rail acc to EN60715
Degree of protectionIP20
Terminal screw torque2.5N·m
ApprovalsTUV
 
Installation Instructions

Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:

  • SPD
    • quantity of SPD
    • type
    • level of exposure to define the SPD's maximum discharge current Imax.
  • Short circuit protection device
    • maximum discharge current Imax;
    • short-circuit current Isc at the point of installation.

The other characteristics for selection of a SPD are predefined for an electrical installation.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.

Location and types of SPD:


Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.

The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.

                                    SPD in plastic enclosure                                                                             SPD in metal enclosure
 

 

RED: Replace
Once the indicator shows RED, the product must be replaced.
  • Similar Products
Full Page Contact Supplier