$10.80
300 Pieces (MOQ)
Dts1560 Three Phase Four Wire Energy Mete
Huadu Electric Technology Co., Ltd
Swipe or use the arrows to view product images.
ATZ1000 Multifunction RS485 Measurement Smart Electric Meter Electrical Power Meter
| Price | $50.00 |
|---|---|
| Min Order | 100 Pieces |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 288 people viewed |
Model NO.:
ATZ1000
After-sales Service:
1 Years
Warranty:
1 Years
Display:
Digital
Installation:
Direct Connected
Usage:
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Theory:
Electronic Meter
Type:
Power Meter
Certification:
ISO, CE
Customized:
Customized
Operating Range:
AC/DC85-265V
Rated:
AC100V/220V/400V
Communication:
RS485 Modbus RTU
Operating Temperature:
-25ºC~55ºC
Storage Temperature:
-40ºC~70ºC
Altitude:
≤2000m
Power Consumption:
≤5W
Cut-out Dimension:
67mm*67mm
H*W*D:
72mm*72mm*55mm
Trademark:
Antin
Transport Package:
Paper Carton + Pallets
Origin:
Hangzhou
Product Description
The ATZ1000 series multifunctionpower Analyzerare featuredin accuratemeasurement and display of various power parameters:voltage,current,power,frequency,activepowerreactive power,forwardpower reverse power,power factor totalharmonic distortion,sub-harmonics,maximum demand,etc.insingle-phasetwo-wire,three-phase three-wire,and three-phase four-wiregrids Itis suitable for real-time power mon-itoring systems and is characterized byits mult-functionaliy,versatiliy,high stability andlong ife.The meter is suitable forallkinds ofhigh andlow-voltage grids with amaximumcurent of 9999 Aand a maximum voltageof 50000 V.Ithasan RS485 communication interface for remotecommunication and is idealfor power and energy monitoring.
Main Features:
- Cycle sampling not less than 128 points,support telematcs, remote control,telemetry
- Compatible with single-phase and three-phase full grid system typeaccess
- Sub-phase and total full powerparameter measurement
- Fractionalharmonic measurement can reach up to 63 times
- Support RS-485 and Ethernet port communication
- Communication rate up to 38400bps
- Five-touch keyoperation,friendlyinterface settings
- High-resolution large screen,wide view area with black characterson gray background
- Sub-phase and total powerand current demand statistics
- Demand calculation mode,update period,slip time can be set
- Real-time display ofthe load ratio sector chart
- Power factor histogram indication
- Bidirectional metering,sub-phase active and reactive power metering
- Unbalanced (NEUTRAL WIRE)current and voltage
- Phase sequence judgment,phase angle display
- Manual and automatic page flip,backlight delay can be set
- 1A/5A transformertype access,variable ratio can be set
- Intelligent setting offorward and reverse wiring of sub-phase transformer
- DI input anti-shake timecan be set according to actual needs
- DO output delay time can be set according toactual needs
- SOE equipment full event record
- Removable batteryfor easy maintenance
- Dn housing,installation size 92*92mm,extrusion typeinstallation,no snap fastening needed
- Plug and unplug connection
| Parameter | Value | |||
| Applicable grid | Three-phase four-wire, three-phase three-wire, single two-wire, three-phase three-wire PT | |||
| Working power | Voltage range | AC/DC85~265V | ||
| Power consumption
| ≤5W | |||
| Input | Voltage | Rated | AC100V,220V,400V | |
| Overload | 1.2 times continuous, 2 times (10s) | |||
| Power consumption | <0.4VA/Phase | |||
| Impedance | ≥200kΩ | |||
| Current | Primary current | 1-9999A | ||
| Secondary input | 1A or 5A | |||
| Short-time overcurrent | 20 times the maximum current for 0.5 seconds | |||
| Power consumption | <0.2VA/Phase | |||
| Impedance | ≥0.1Ω | |||
| Frequency | 45Hz~65Hz | |||
| Switching input | Dry contact input, photoelectric isolation | |||
| Output | Switching output | Relay output; can set any alarming power, default remote control | ||
| Pulse output | 1 channel electrical energy pulse | |||
| Accuracy index | Voltage/current | 0.5% | ||
| Frequency | 0.2% | |||
| Power/power factor | 1% | |||
| Active power | Class0.5S | |||
| Reactive power | CLass2 | |||
| Communication | Bus type | RS485 | ||
| protocol | Modbus RTU | |||
| Baud rate | 2400/4800/9600/19200/38400bps | |||
| Address range | 1-247 | |||
| Bus load | 64pcs | |||
| Communication distance | 1000m | |||
| Parity | EVEN/ODD/NONE(default) | |||
| Data bits | 8 | |||
| Stop bit | 1 | |||
| Ethernet por | Modbus | |||
| Environment | Operation temperature | -25ºC~55ºC | ||
| Storage temperature | -40ºC~70ºC | |||
| Operating humidity | ≤90%RH, non-condensing, no corrosive air | |||
| Storage humidity | ≤95%RH, non-condensing, no corrosive air | |||
| Altitude | ≤2000m | |||
| Installation category | CATIII | |||
| Withstanding voltage capacity | AC withstanding voltage 4KV/1min Pulse withstanding voltage 6kV - 1.2µS waveform | |||
| IP Class | IP51(Indoors) | |||
| Insulation class | 2 | |||
| Average trouble-free operation time | ≥50000h | |||
| EMC electromagnetic compatibility test | Electrostatic discharge immunity test | GB/T 17626.2-2006:test level 4, test voltage 8kV | ||
| RF electromagnetic field immunity test | GB/T 17626.3-2006:test level 3, test field strength of 10V / m | |||
| Fast transient pulse group test | GB/T 17626.4-2008:test level 2, current voltage 1kV, other 500V | |||
| Surge (shock) immunity test | GB/T 17626.5-2008:test level 4, test voltage 4kV | |||
| RF field induction conducted harassment immunity test | GB/T 17626.6-2008:test level 3, test field strength of 10V / m | |||
| Voltage transients, short interruptions and voltage changes in the immunity test | GB/T 17626.11-2008:current and voltage test error qualified | |||
| Oscillation wave immunity test | GB/T 17626.12-1998:Class B ITE test, qualified | |||
| Conformity to Standards | GBT22264.1-2008 Mounted digital display electrical measuring instrument Part 1: Definition and general requirements | |||
| GBT22264.7-2008 Mounted digital display electrical measuring instrument Part 7: Special requirements for multifunctional instruments | ||||
| GBT22264.8-2009 Mounted digital display electrical measuring instrument Part 8:Recommended test methods | ||||
- Similar Products
$50.00
100 Pieces (MOQ)
Modbus RTU Prepaid Energy Meter for Three Phase Systems
Hangzhou Antin Power Technology Co., Ltd.
$10.00
1 Piece (MOQ)
Anti-Tamper Load Control 2 Copper Shunt Kwh Meter Energy Meter
IVY METERING CO., LTD.