Acrel Am3se Medium Voltage Protection Relay for PT Supervision Am3se-U
| Price | $311.50 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 529 people viewed |
Model NO.:
AM3SE-U
Theory:
Voltage Relay
Usage:
Voltage Relay
Phase:
3
Electricity Type:
Ac
Load:
Micro Power Relay
Protective Characteristics:
Open Relay
Action Principle:
Electronic Type
Size:
Miniature
Type:
Electric Parameter Relay
Power Supply:
AC/DC220V, or AC/DC110V, or DC48V, or DC24V
Rated Input Voltage:
1-120V
Rated Input Current:
AC 5A /1A
Rated Frequency:
45-55Hz or 60Hz
Trademark:
Acrel
Transport Package:
Carton
Specification:
28*30*20mm
Origin:
Shanghai, China
HS Code:
9030339000
Product Description
AM series protection relay are applicable to the user substation which the input voltage is 35kv and below. We adopt mature technology solutions to ensure the quality of the AM relay.The AM relay are widely used in substations, subsection posts and ring main units for office buildings, commercial buildings, communication buildings, mine buildings and so on.
Protection functions | AM3SE-I | AM3SE-U |
Overcurrent (3 stages,IDMT) | √ | |
Earth fault (3 stages,IDMT)(I01/I02) | √ | |
Negative sequence overcurrent (2 stages,IDMT) | √ | |
Auto-reclose | √ | |
Overload (trip/alarm) | √ | |
Under frequency | √ | |
Post-accelerated overcurrent | √ | |
Post-accelerated overcurrent(I01/I02) | √ | |
Overvoltage(trip) | √ | |
Undervoltage (trip) | √ | |
Self-produced over zero-voltage (trip) | √ | |
Residual overvoltage (trip) | √ | |
FC block | √ | |
Trip and close circuit supervision (alarm) | √ | |
Non-electricity (trip/alarm) | √ | |
Undervoltage (alarm) | √ | √ |
Overvoltage (alarm) | √ | √ |
Residual overvoltage (alarm) | √ | √ |
PT supervision (alarm) | √ | √ |
Self-produced over zero-voltage (alarm) | √ | |
Rear ports | I | U |
RS485 | √ | |
Protocols | I | U |
Modbus serial | √ | |
IEC 60870-5-103 | √ | |
Measurement | I | U |
Electric parameter | U,I,P,Q,PF,Fr,Ep,Eq,Es | |
Input Current | 5 | 5 |
Input Voltage | 3 | 3 |
Logs and Records | I | U |
Fault recorder | √ | |
Sequence of event record | √ | |
Monitoring Functions | I | U |
Anti-pumping circuit | Optional | |
Remote control | √ | |
FAQ
Q: How to set the CT and PT ratio of the protection device?
A:The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and
the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.
Q: How to distinguish the model when place order of AM3SEthat a single line protection and transformer protection?
A: A AM3SE is suitable for circuit protection and transformerprotection. No need to distinguish between models when placing
orders.
Q: When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?
A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.
Q: How to confirm whether the anti-trip function is configured?
A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)
Q: How to purchase suitable protection devices?
A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.
A:The protection device can set the CT and PT ratio through the fixed value menu. For example, the current transformer is 75/5 and
the voltage transformer is 10/0.1, then the CT ratio is set to 15 and the PT ratio is set to 100.
Q: How to distinguish the model when place order of AM3SEthat a single line protection and transformer protection?
A: A AM3SE is suitable for circuit protection and transformerprotection. No need to distinguish between models when placing
orders.
Q: When the voltage is three-phase three-wire system, does the current have to be connected with 2CT?
A: The voltage wiring mode and current wiring mode of the protection device can be set independently, and can be connected freely.
Q: How to confirm whether the anti-trip function is configured?
A: If the circuit breaker is equipped with anti-trip, the device does not must be equipped with anti-trip; if the circuit
breaker does not have anti-trip, you need to configure the AM5-FT anti-trip module. (If DC48V is selected as the
operating power supply, the anti-trip box is not optional, and the circuit breaker must be equipped with anti-trip
function; if you choose AC anti-trip, please note that AC and DC general anti-tripping)
Q: How to purchase suitable protection devices?
A: Before ordering, it is recommended to consult related engineers, select the appropriate protection model,
and then fill in the corresponding selection table, and place the order after confirmation by the engineers.
Customer
- Similar Products
$9.40
10 Pieces (MOQ)
DIN Rail Mount Solid State Relay with Heat Sink Da/AA 40AMP Module
ZONZEN GROUP LIMITED
$0.70
10 Pieces (MOQ)
20A 30VDC Power Relays for Hazardous Locations
Zhejiang Fanhar Electronics Co., Ltd.
$0.30
1000 Pieces (MOQ)
Relay Original 28VDC 6feet 20A Mini PCB Switching Wl4117
Jiangxi Weiqi Electric Co., Ltd.