Advanced Anesthesia Machine Used in Hospital ICU Room with Good Anesthesia Vaporizer/Anesthesia Ventilator/Gas Anesthesia

Price $6600.00
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 361 people viewed
Model NO.:
DP-850
Type:
Anaesthesia Machine
Kind:
Gynaecology
Certification:
CE, ISO13485
Group:
Adult
LCD Display:
Without LCD Display
G.W:
114kg
Safety Valve:
<12.5 Kpa
Respiratory Rate:
1~99bpm
Oxygen Flush:
25~75 L/Min
Trademark:
DARPPON
Transport Package:
Mood and Paper Packaging
Specification:
94*70*79*127cm + 70*68*37cm
Origin:
China
HS Code:
90189070
Product Description
850 Factory direct multi-functional surgical use anesthesia machine
 
 
Product Name850 Factory direct multi-functional surgical use anesthesia machine
TECHNIQUES SPECIFICATIONS
Physical specifications
Screen:
10.4 '' LCD Display Screen
Suitable
Adult & Child
Mode:
pneumatically powered and electrically

controlled system
Working Mode:
Closed; Semi-Closed; Semi-Open
Circuit
Breathing circuit integrated standards
Flowmeters:
5 Tubes Flowmeters: O2:0.1~10L/Min,

N2O:0.1~10L/Min; Air: 0.1~10L / Min
Trolley:
Fitted with 4 nos anti-static rubber castors;

two of which are lockable for braking and easy

maneuverability with foot operated brake

provisions
Drawer unit
TWO drawers totally extractable
Technical Specifications:
Gas requirement:
Medical oxygen and nitrous oxide with a pressure ranging from

O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa.
safety valve
<12.5 kPa
Respiratory Rate
1~99bpm
oxygen concentration in the mixed gas N2O/O2
> 21%
Oxygen Flush:25~75 L/min
modes of ventilation
A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, SIGH, PEEP,

MANUAL
PEEP:
0 ~ 20 hPa
Ptr:
-10 ~ 20 hPa
IMV frequency:
1 ~ 20 bpm
I/E Ratio:
8:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume
0 ~ 1500 ML
Inspiratory Plateau:
0~1s
O2 Concentration:
21%~100%
Sigh:
one deep breath per 70 ~ 120 controlled respirations, the

inspiration time is 1.5 times of the setting point
Maximum safety pressure:≤ 12.5 kPa
Pressure limit range:0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicatingupper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Oxygen concentration alarm: Audible and visual and with yellow and red color indicatingupper alarm: 21% ~100%; lower alarm:10%~80%
Power Supply Alarm
Ac/dc power supply are after failing to send out alarm

immediately

Alarm Time: keep >120s
 
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine

will raise an audible alarm, the pressure will be displayed in red and the continuous high

pressure red alarm wording is displayed on the screen of the anesthetic respirator.