Air to Water DC Inverter Heat Pump Split Type for Low Temperature Area

Price $2500.00
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 460 people viewed
Model NO.:
RF8I/bdm --HF20I/bdm
Certification:
SASO, CCC, ISO9001, CE, TUV
Working Medium:
R410A
Heat Source Type:
Air Source Heat Pump
Product Name:
Air to Water Heat Pump Water Heater
Rated Outlet Hot Water Temperature:
55 Degree
Maximum Outlet Hot Water Temperature:
58 Degree
Compressor:
Gmcc
Refrigerant:
R410A
Usage:
Water Heater
Control Type:
Digital
Display Type:
LCD
Material:
Colored Steel Casing
Working Range:
-30--43 Degree
Power Supplier:
220V/1/50Hz
Heating Capacity (Kw):
9kw-20kw
Power Input (Kw):
2.59-5.81
Cooling Capacity (Kw):
8-12
Cooling Input(Kw):
3.2-4.8
Trademark:
KONNEN
Transport Package:
Safe Export Packing
Specification:
RF8I/bd--RF16I/bd
Origin:
China
HS Code:
8418612090
Product Description
KONNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:
* GMCC Compressor with R410A;
* High efficiency hydrophilic aluminum foil fin heat exchanger;
* "SANHUA" EEV;
* "Lifeng" fan ;
* Delivery time:about 30days after received deposit;
* Payment:T/T 30% prepaid ,then pay for the balance before delivery;
*Package:ply-wood cases;
* Warrenty:18month;

WE SUPPLY OEM SERVICE!

KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):

WHY US:

KONNEN NEW PROJECTS:

WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:

KONNEN HEAT PUMPS LOADING:

PARAMETERS TABLE:
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING
ModelRF8I/bdm
(3HP)
RF12I/bdm
 (5HP)
RF13I/bdm
(6HP)
HF20I/bdm (8HP)
Rated HeatingHeating capacitykW9.00 15.00 18.00 20.00 
Power inputkW2.59 4.31 5.14 5.81 
COPW/W3.47 3.48 3.50 3.44 
Nominal HeatingHeating capacitykW5.53 10.50 12.10 14.50 
Power inputkW2.34 4.43 5.13 6.01 
COPW/W2.36 2.37 2.36 2.41 
IPLV(H)W/W2.80 2.85 2.85 2.86 
Low Temp. HeatingHeating capacitykW4.50 8.90 10.10 12.50 
Power inputkW2.34 4.56 5.10 5.95 
COPW/W1.92 1.95 1.98 2.10 
Rated CoolingCooling capacitykW8.00 11.50 12.00 /
Power inputkW3.20 4.60 4.80 /
EERW/W2.50 2.50 2.50 /
Power SupplyV/Ph/Hz220/1/50
Max. Power Input
(With E-Heater)
kW4.4(+3)5.2(+3)6.6(+3)7.1(+3)
Max. Current Input
(With E-Heater)
A20(+13.6)23.7(+13.6)30(+13.6)32.5(+13.6A)
Max. Water Temp.
(Without E-Heater)
ºC58
Working Range
(Ambient temp.)
ºC-30 to 43-35 to 43
Cooling CirculationRefrigerantTypeR410A
Qty./Kg1.73.153.153.15
CompressorQty.1
TypeDC INVERTER DOUBLE ROTOREVI DC INVERTER DOUBLE ROTOR
BrandGMCC
EvaporatorTypeHigh efficiency hydrophilic aluminum foil fin heat exchanger
EEVBrandSANHUA
Fan MotorQty.12
Power Input(W)1402*150
Fan Blades SizemmΦ560*139Φ525*135
Liquid valve sizeinch(mm)3/8"(9.52)
Gas valve sizeinch(mm)5/8"(15.88)
Water systemCondenserTypeTube in tube heat exchanger
Water PumpBrandXINHU
ModelGPD25-12S
Water Flowm3/h1.381.982.062.5
Water Dropkpa35353848
Air Vent Valve Standard
Pressure Release Valve Standard
Pressure value3kgs
E-HeaterkW3
Buffer TankL5
Water Inlet/Outlet Pipe Sizeinch(mm)5/4" male
Net Dimensionsindoor Unit (L*W*H)mm760x510x330
Outdoor Unit (L*W*H)mm947x403x813940x393x1373
Package Sizeindoor Unit (L*W*H)mm795x562x373
Outdoor Unit (L*W*H)mm1050x468x8471060x490x1395
N.W.Indoor Unitkg43
Outdoor Unitkg63110115
G.W.Indoor Unitkg48
Outdoor Unitkg70125130
Noise LevelIndoor UnitdB(A)≤35
Outdoor UnitdB(A)≤59.5≤61.5≤62
Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016                                                                                                     
Testing Condition:                                                                                                                         
- Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.          
                                                                                      