Swipe or use the arrows to view product images.
Air to Water Heat Pump High Temperature with High Cop
| Price | $13000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 449 people viewed |
Model NO.:
A03H
Heat Temperature:
80-90°C
Work Environment:
Common Heat Pump
Heat Source:
Air-source
Heating Type:
Circulating Heat
Application:
Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification:
CE, ISO9001, CCC, CB, RoHS, SASO
Product Name:
Commercial Use Air Source Heat Pump (Ckfxrs-70II)
Rated Heating Capacity:
12kw~210kw
Suitable Environment:
-25~52
Color:
Dark Black-Grey or White
Controller:
Konnen Brand
Testing:
25HP National Proved Laboratory
Trademark:
KONNEN
Transport Package:
Safety Export Packing, with Pallet
Specification:
Standard
Origin:
China (Mainland)
HS Code:
8418612090
Product Description
High temperature of air to water heat pump water heater, air source heat pump, heat pump, heat pump water heater, heat pumps, with Copeland compressor and R134a refrigerant, lowest working temperature can reach -15 deg C, max. water output temperature 80 deg C.
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
HEAT PUMP LOADING:
PRODUCT FEATURES:
PARAMETERS TABLE:
AIR TO WATER HEAT PUMP, AIR SOURCE HEAT PUMP, HIGH TEMPERATURE HEAT PUMP, HEAT PUMP WATER HEATER, HEAT PUMP, HEAT PUMPS.
| * Copeland compressor & R134a refrigerant; |
| * Stainless steel 304 for all fasteners, for side covers of evaporator; |
| * Preservative oil for copper tubes and all important part of cabinet; |
| * Chinese No.1 brand "ND" shell & tube heat exchanger; |
| * Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
| * "Sanhua" 4-way valve; |
| * "Schneider" AC contactor & Relay |
| * KONNEN LCD controller; |
| * Delivery time: 25~30 days; |
| * Payment term: T/T 30% in advance and T/T 70% before delivery; |
| * Warranty time: 24 months after delivery. |
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
WORLD FAMOUS BRAND WE COOPERATED FOR OUR HEAT PUMPS:
HEAT PUMP LOADING:
PRODUCT FEATURES:
PARAMETERS TABLE:
| A03H (High temperature of air source heat pump water heater circulation type) | ||||||||||||||
| HT3Ps-T3 | HT5sP-T5 | HT3P-T3 | HT5P-T5 | HT7P-T5 | HT10P-C24 | HT14P-C24 | HT20P-C48 | HT24P-C48 | HT30P-C48 | HT36P-C48 | HT48P-C96 | |||
| Rated heating capacity | kW | 8 | 13.5 | 8 | 13.5 | 18 | 26 | 35 | 55 | 65 | 80 | 95 | 130 | |
| Rated input power | kW | 2.2 | 3.65 | 2.19 | 3.66 | 4.96 | 7.11 | 9.62 | 14.91 | 17.81 | 21.98 | 26.03 | 35.81 | |
| Rated input current | A | 9.58 | 15.9 | 4.14 | 6.92 | 9.37 | 13.55 | 18.17 | 28.17 | 33.66 | 41.54 | 49.19 | 67.69 | |
| Maximum input power | kW | 2.86 | 4.75 | 2.74 | 4.58 | 6.20 | 8.89 | 12.02 | 18.63 | 22.26 | 27.47 | 32.53 | 44.77 | |
| Maximum input current | A | 14.92 | 24.77 | 5.34 | 8.92 | 12.09 | 17.33 | 23.44 | 36.33 | 43.41 | 53.57 | 63.44 | 87.29 | |
| Performance coefficient(COP) | / | 3.63 | 3.69 | 3.65 | 3.69 | 3.63 | 3.65 | 3.64 | 3.69 | 3.65 | 3.64 | 3.65 | 3.63 | |
| Rated hot water output temp. | ºC | 75 | ||||||||||||
| Maximum hot water output temp. | ºC | 80 | ||||||||||||
| Rated hot water produce capacity | △t40 | L/H | 172.0 | 290.2 | 172.0 | 290.3 | 387.0 | 559.0 | 752.5 | 1182.5 | 1397.5 | 1720.0 | 2042.5 | 2795.0 |
| △t60 | L/H | 114.7 | 193.5 | 114.7 | 193.5 | 258.0 | 372.7 | 501.7 | 788.3 | 931.7 | 1146.7 | 1361.7 | 1863.3 | |
| Power supply | 1N 220V/50Hz | 3N 380V/50Hz | ||||||||||||
| Compressor | Type | Hermetic scroll type | ||||||||||||
| Start Mode | Directly start | |||||||||||||
| Quantity | Set | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 4 | 2 | 3 | 3 | 4 | |
| Water side heat exchanger | Type | Shell & coil(tube) heat exchanger | ||||||||||||
| Water flow | m3/h | 1.4 | 2.3 | 1.4 | 2.3 | 3.1 | 4.5 | 6.0 | 9.5 | 11.2 | 13.8 | 16.3 | 22.4 | |
| Water Pressure Drop | kPa | ≤45 | ≤53 | <50 | <55 | <57 | <60 | <60 | <65 | <65 | <65 | <65 | <65 | |
| Pipe size | mm | DN20 | DN25 | DN20 | DN25 | DN25 | DN32 | DN32 | DN50 | DN50 | DN50 | DN65 | DN80 | |
| Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, etc.. | |||||||||||||
| Refrigerant | Type | R134a | ||||||||||||
| Throttle Type | Electronic expansion valve | |||||||||||||
| Quantity | kg | 2.1 | 3.3 | 2.1 | 3.3 | 4.3 | 2.8×2 | 4.1×3 | 3.2×4 | 7.6×2 | 6.2*3 | 7.6×3 | 7.6×4 | |
| Noise | DB(A) | ≤55 | ≤63 | ≤55 | ≤63 | ≤65 | ≤65 | ≤68 | ≤70 | ≤72 | ≤73 | ≤74 | ≤78 | |
| Dimension | mm | 700×680× 875 | 860×820× 1080 | 700×680× 875 | 860×820× 1080 | 860×820× 1080 | 1000×1000× 1858 | 1000×1000× 1858 | 1000×2050× 1900 | 1000×2050× 1900 | 1000×2050× 1980 | 1000×2050× 1980 | 2000×2050× 1980 | |
| Net Weight | kg | 100 | 170 | 100 | 170 | 190 | 310 | 410 | 605 | 650 | 835 | 840 | 1250 | |
| Testing conditions: | ||||||||||||||
| 1. Application side initial water temperature: 15ºC, end temperature 75ºC, max. temperature 80ºC. | ||||||||||||||
| 2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. | ||||||||||||||
| The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us. | ||||||||||||||
| The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. | ||||||||||||||
AIR TO WATER HEAT PUMP, AIR SOURCE HEAT PUMP, HIGH TEMPERATURE HEAT PUMP, HEAT PUMP WATER HEATER, HEAT PUMP, HEAT PUMPS.