Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Biobase 190-900nm Wavelength Atomic Absorption Spectrophotometer Bk-AA320n for Lab

Price $8000.00
Min Order 1 Piece
Availability In Stock
Shipping From Shandong, China
Popularity 544 people viewed
Model NO.:
BK-AA320N
After-sales Service:
Online Service
Application:
Laboratory Apparatus
Warranty:
1 Year
Detection Method:
Spectrophotometer
Advantage:
High Sensitive
Principle:
Classic Spectrometer
Wavelengths:
Atomic
Dispersive Element:
/
Light Number:
/
Certification:
CE
Customized:
Non-Customized
Model:
Bk-AA320n
Color:
White
Warranty Time:
One Year
Wavelength Range:
190~900nm
Wavelength Accuracy:
≤±0.5nm
Wavelength Repeatability:
≤ 0.3nm (Single Direction)
Spectral Bandwidth:
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Grating:
1800 Lines/mm
Resolution:
<40%
Base Line Stability:
±0.004ABS/30min
Characteristic Concentration:
≤ 0.04μg/Ml/1% (Cu)
Detection Limit:
≤0.008μg/Ml (Cu)
Background Calibration:
Higher Than 30 Times
Power Supply:
220V, 50/60Hz
Gross Weight(Kg):
138kg (Main Instrument) 56kg ( Accessories )
Trademark:
BIOBASE
Transport Package:
Carton
Specification:
138kg
Origin:
China
Product Description
Product Description

BIOBASE 190-900nm wavelength Atomic Absorption Spectrophotometer BK-AA320N for lab



Features:
1. Build-in computer data processing and LCD display.
2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift.
3. Quickly: The cathode lamp does not need to be pre-heated for long time and sample can be analyzed immediately.
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
6. High energy optical path.
7. Long-life and anti-corrosive atomization system.
8. Multi-functional analysis mode: ?flame absorption?flame emission? graphite furnace atomic absorption 4 hydride generation.
9. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

 
Detailed Photos

 

Product Parameters

 

Model

BK-AA320N

Wavelength Range

190~900nm

Wavelength Accuracy

≤±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Grating

1800 lines/mm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration

≤ 0.04μg/ml/1% (Cu)

Detection Limit

≤0.008μg/ml (Cu)

Background Calibration

>30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250*795*765 (Main instrument)

545*445*1385 ( Accessories )

Gross Weight(kg)

138Kg (Main instrument)

56Kg ( Accessories )

Standard Accessories

RS232 serial port

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit, Burner unit ,Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories

Model GA3202 HGA graphite furnace system

Hydride generator

Graphite tubes

Recirculating cooling water system

Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)