Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Biobase High-Precision Liquid Automatic Sampler Gas Chromatograph for Lab

Price $1000.00
Min Order 1 Piece
Availability In Stock
Shipping From Shandong, China
Popularity 368 people viewed
Model NO.:
BK-GC901
After-sales Service:
Online Support
Warranty:
1 Year
Appliance:
The Analysis of Environmental Samples
Ray Type:
Gamma Ray Spectrometer
Gaspath System:
Double
Detector:
Silicon Photodiode
Energy Resolution:
≤7%
Certification:
/
Spectrometer Detector:
SDD
Stationary Phase:
Solid Adsorbent
Mobile Phase:
Liquid
Chromatography Type:
Liquid Chromatography
Chromatographic Column Type:
Convetional Analytical Column
Chromatographic Column Length:
10~30cm
Chromatographic Column Diameter:
20~40mm
Model:
Bk-Gc901
Capacity:
22L
Temp. Range:
Rt+5~400
Temp. Program:
16-Phase
Program Total Time:
9999.9 Min
Max Temp. Heating Rate:
60/Min
Pre Column Pressure Accuracy:
0.1 Kpa
Temp. Ranges:
Rt+7~420
Optional Accessory:
Tcd Detector
Package Size(W*D*H):
735*725*835mm
Gross Weight:
80kg
Trademark:
BIOBASE
Transport Package:
Paper Packaging
Specification:
9
Origin:
China
Product Description

Product Description

 

Introduction:
BK-GC901 gas chromatograph can realize full EPC electronic flow control, realize full computer control of the instrument, and can be equipped with a high-precision liquid automatic sampler. It can be widely used in many fields such as petroleum, chemical industry, environmental protection, food safety, disease control, education and scientific research, and can analyze the macro, micro and trace amounts of organic matter, inorganic matter and gas.

 
 

Detailed Photos

Model

BK-GC901

Oven

Temp. Range

RT+5~450ºC

Temp. Accuracy

≤±0.01ºC

Temp. Program

16-phase

Max. Temp. Heating Rate

40ºC/min

Time Range

0-999.9min

Detector

Hydrogen Flame Ionization Detector (FID)

Detection limit:≤5×10-12g/s

(100ng/ul n-hexadecane-isooctane solution)

Temperature 450ºC

Compatible with packed and capillary columns

Baseline drift:≤2x10-13A/30min

Baseline noise: 3×10-14A

Linear range:≥107

Thermal Conductivity Detector (TCD)

Sensitivity: >5000mv.ml/mg

(50mg/ml toluene-benzene solution)

Temperature 400ºC

Baseline drift:≤0.1mV/30min

Baseline noise: 0.03mV

Linear range:≥105(±10%)

Electron Capture Detector (ECD)

Detection limit:≤1×10-14g/ml

(Sample: n-hexadecane δ-666)

Linear range: ≥104

Flame Photometric Detector (FPD)

Detection limit:≤5×10-12g/s(S of 10ng/uL methyl parathion-ethanol solution)

Detection limit:≤4×10-12g/s(P of 10ng/uL methyl parathion-ethanol solution)

Linear range (S): ≥103 

Linear range (P): ≥104 

Temperature 350ºC

Nitrogen and Phosphorus Detector (NPD)

Detection limit:≤1×10-12g/s (Azobenzene)

Detection limit:≤1×10-12g/s(Marla sulfur phosphorous)

Linear range: ≥103

Injection Method

Capillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc.

Inlet

1~4, up to 3 capillary column inlets

Injection Type

Packed column injection, capillary column injection. (Flow setting range: 0~1000ml/min)

Control Accuracy

Pressure: 0.01KPa; Flow: 0.01ml/min

Maximum Split Ratio

1:999

Pressure Sensor

Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa

Flow Sensors

Accuracy: < 5% of full scale; Repeatability: 0.5K Pa (full scale); Output offset (accuracy): ±5%

Sampling Valve

Can be equipped with multiple imported automatic control valves, which can run automatically in sequence

Power Supply

AC220V±10%, 50/60Hz

Standard Accessory

FID detector, Chromatography workstation software, Capillary sampler  

Optional Accessory

Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.

Package Size (W*D*H)

750*710*720 mm

Gross Weight

70kg

Features:

High-precision gas flow control system (EPC)

.High-precision gas flow control, to ensure the accuracy of GC analysis, to ensure the efficiency of daily analysis, EPC control accuracy 0.01psi

.It realizes the self-protection of gas circuit failure, automatic ignition, re-ignition, automatic opening of the gas circuit, and one-key start.

A variety of control combination modes of operation, automatic pressure and flow adjustment, control and display, can operate in gas-saving mode

 

Color widescreen, unique design of touch keys

7-inch industrial color LCD screen design, more complete display information, more reasonable interface operation

Have two sets of operating systems in Chinese and English to meet different user needs

Adopt resistive touch screen, feel good, durable, double operation of screen and software to achieve seamless connection

 

Leading structural design

Modular structure design, easy to upgrade, can be equipped with a variety of high-performance detectors such as FID, TCD, ECD, FPD and NPD, etc., to meet the analysis needs of complex samples

.Advanced sampler design, unique liner structure and special processing technology to ensure zero adsorption of samples

 Adapt to a variety of sample injection methods such as: headspace sampler, thermal desorption analyzer, liquid automatic sampler, easily competent for the analysis of various sample types

Timed self-starting program can easily complete the laboratory online analysis of gas and liquid samples

 

Humanized software operating system

Adopt advanced 10/100M self-adaptive Ethernet communication interface, built-in IP protocol stack, easily form a local area network, realize long-distance transmission, remote control, and remote diagnosis.

Equipped with IBrainChrom workstation, which can support multiple chromatographs (253 sets) to work at the same time, realize data processing and reverse control.

Have complete audit trail, user rights management, electronic signature and other functions, so that data and documents meet GMP management requirements

The built-in Modbus/TCP server of IBrainChrom workstation can easily connect the analysis results to DCS (distributed control system)

3 independent connection threads that can be connected to local, laboratory supervisors and authorities, allowing them to monitor the operation of the instrument and analyze the data in real time.

 

 

Product Parameters

 
 
         Gas Chromatograph                                             Density meter                                     Kjeldahl nitrogen analyzer

                     Refrigerator                                             Dry bath incubator                                      Nucleic acid extractor

 

 

Packaging & Shipping

Installation Instructions

 

Company Profile

 

After Sales Service

1. who are we?
We are based in Shangdong, China, start from 2017,sell to Eastern Asia(12.00%),South America(11.00%),Southeast
Asia(10.00%),Africa(10.00%),Mid East(10.00%),Northern Europe(10.00%),South Asia(10.00%),Eastern Europe(6.00%),Western
Europe(6.00%),North America(5.00%),Central America(3.00%),Southern Europe(3.00%),Oceania(2.00%),Domestic Market(2.00%). There are
total about 1000+ people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Pharmacy Instrument,Blood Bank Instrument,Disinfection &Sterilization Instrument,Air Protection Products,Clinical&Analytical
Products
4. why should you buy from us not from other suppliers?
We are committed to create the most perfect quality, to win the highest level of customer recognition. Every score and every good comment from you is the driving force that motivates us to move forward. Thank you for your recognition and encouragement. 
We will continue to move forward!
5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,CIP,FCA,CPT,DDP,DDU;
Accepted Payment Currency:USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T,L/C,Credit Card,Western Union,Cash;
Language Spoken:English,Chinese,Spanish,Japanese,Portuguese,German,Arabic,French,Russian,Korean,Hindi,Italian

contact Dolores

  • Similar Products