Swipe or use the arrows to view product images.
Carbon Disulfide Gas Electrochemical Sensor
| Price | $68.70 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Hubei, China |
| Popularity | 254 people viewed |
Model NO.:
4CS2-10
Type:
Electrochemical Gas Sensor
Conductivity Type:
Surface Type
Output Signal Type:
Analog Type
Production Process:
Integration
Material:
Plastic
IP Rating:
IP65
Sensitivity:
Medium
Certification:
RoHS
Customized:
Customized
Operating Principle:
3-Electrode Electrochemical
Detection Range:
0~20 Ppm
Response Time (T90):
≤50s
Repeatability:
<±2% Signal
Measurement:
<2% Signal/Month
Trademark:
AERI
Transport Package:
Packing Bottle
Specification:
30ml
Origin:
China
HS Code:
4204960212
Product Description
4CS2-10 Carbon Disulfide Electrochemical Sensor
(P/N: SEC-4CS2-10)
(P/N: SEC-4CS2-10)
| Technical Specifications | ||
| MEASUREMENT | ||
| Operating Principle | 3-electrode electrochemical | |
| Detection Range | 0~10 ppm | |
| Sensitivity | 2.0 ± 1.0 mA/ppm | |
| Response Time (T90) | ≤50 s | |
| Repeatability | <±2% signal | |
| Linearity | Linear | |
| MEASUREMENT | <2% signal/month | |
ELECTRICAL | ||
| Resolution | 0.1 ppm | |
| Recommended Load | 5~50 | |
| Bias Voltage | 300 mV | |
ENVIRONMENTAL | ||
| Operating Temp. Range | -20°C ~ 50°C | |
| Operating Humidity Range | 15% RH ~ 90% RH non- condensing | |
| Operating Pressure Range | 800 ~ 1200 mbar | |
LIFETIME | ||
| Recommended Storage Temp. | 0°C to +20°C in sealed container | |
| Expected Operating Life | 24 months in air | |
| Standard Warranty | 12 months | |
Product Dimensions
All dimensions in millimeters (± 0.1mm)
| Cross-sensitivity Data | ||
| Gas | Concentration(ppm) | Output signal (ppm CS2 equivalent) |
| Hydrogen gas | 10 | 2 |
| Ammonia | 50 | 0.1 |
| Nitrogen dioxide | 10 | 0 |
| Chlorine gas | 1 | 0 |
| Methane | 30000 | 0 |
| Carbon monoxide | 10 | 10 |
| Hydrogen sulfide | 10 | 0 |
SAFETY NOTE:
Connection should be made via a PCB mounting socket. Soldering to pins will void the sensor's warranty.
It is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation;
If the Gas Sensor is removed from application circuit, a jumper should be added on 'R' and 'S' pin.
As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own. The data is given for guidance only. It does not constitute a specification or an offer for sale.