Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Cautery Machine Electrosurgical Unit Surgical Diathermy Machine

Price $2285.00
Min Order 1 Piece
Availability In Stock
Shipping From Guangdong, China
Popularity 508 people viewed
Model NO.:
MCS-ES005
Material:
Steel
Certification:
CE
Group:
Children, Adults, Elderly
Product Name:
Surgical Diathermy Machine
Operating Frequency:
512kHz
Power Rating:
880va±10%
Power Consumption:
<=880va
Pure Cut:
0W~300W( Load 800Ω)
Blend1:
0W~250W(Load 800Ω)
Blend2:
0W~150W(Load 800Ω)
Contact Coag:
0W~80W( Load 800Ω)
Forced Coag:
0W~120W( Load 800Ω)
Bipolar Coagulation:
0W~50W( Load 100Ω)
Trademark:
MeCan
Transport Package:
Standard Export
Specification:
standard size
Origin:
Guangzhou, China
Product Description

Cautery Machine Electrosurgical Unit Surgical Diathermy Machine 

Model: MCS-ES005
Max 400W Electrosurgical Generator, with mono-polar and bipolar function.Nine working modes: pure cut, blend1, blend2, blend3,
contact coag, forced coag, soft coag, bipolar coag, bipolar cut. Wide clinical applications, such as the general surgery, thoracic
surgery, orthopedic surgery, cardiology, gynecology, urology(under water TUR), oncology, neurosurgery, etc.


Features
1. The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures
2. Touch control panel, three-way power output, with different audible and visual indication during the process of outputting.
3. Patient return electrode monitoring system and Power Peak System that provides surgeons with improved performance at Lower power settings, minimizing the risk of tissue damage.
4. Applicable for Prostate Vaporizing Surgical Operation(TUR), perfectly used under water. The electrosurgical generator can be cooperated with argon plasma coagulator, endoscope and laparoscope.
5. Pencil Remoting Output. The output power can be controlled by the remoting control pencil.


Parameter

Power
220V±22V, 50Hz±1Hz(110V±11V, 60Hz)
Operating frequency
512KHz
Power rating
880VA±10%
Pure cut
 0W~300W( Load 800Ω)
Blend1
0W~250W(Load 800Ω)
Blend2
0W~150W(Load 800Ω)
Contact Coag
0W~80W( Load 800Ω)
Forced Coag
0W~120W( Load 800Ω)
Bipolar Coagulation
0W~50W( Load 100Ω)
Power Consumption
≤880VA

Configuration

Electrosurgical Pencil
5pcs
Power Control Pencil
1pc
Electrosurgical Pad
10pcs
Electrosurgical pad cable
1pc
Footswitch
1set
Bipolar Forceps and cable
1set


Details Images