Cdu for Cold Plate Liquid Cooling and Immersion Cooling

Price $1200.00
Min Order 1 Piece
Availability In Stock
Shipping From Shanghai, China
Popularity 608 people viewed
Model NO.:
CDU1500W
Energy Efficiency Grade:
Three
Heat Temperature:
50-70°C
Work Environment:
Common Heat Pump
Heat Source:
Liquid
Heating Type:
Liquid Cooling
Application:
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital
Certification:
CE, ISO9001, RoHS
Weight (Kg):
150
Video Outgoing-Inspection:
Provided
Machinery Test Report:
Provided
Core Components:
Pump
Place of Origin:
Shanghai, China
Brand Name:
Shenglin
Product Name:
Cdu
Color:
Black or White
Voltage:
Customized
Capacity:
20-1500/3000kw
After-Sales Service Provided:
Online Support
Power Supply:
380V-420V/3pH/50Hz-60Hz
Application 1:
Data Center Cooling
Application 2:
High-Performance Computing (Hpc)
Application 3:
Edge Computing
Trademark:
Shenglin
Transport Package:
Wooden Box
Specification:
CE, ISO, ROHS, BV, SGS
Origin:
Shanghai, China
HS Code:
8415830000
Product Description

Cdu for Cold Plate Liquid Cooling and Immersion Cooling

Product Description

The Coolant Distribution Unit (CDU) is the central component of the water cooling system, responsible for efficiently distributing the cooling medium to meet the cooling needs of various applications. It ensures the system operates stably by incorporating additional monitoring and support devices. The CDU on the secondary side of the heat exchange unit is primarily used for controlling heat exchange in liquid cooling heat sink systems. This system includes a frequency conversion circulating pump, plate heat exchanger, electric control valve, temperature sensor, pressure sensor, filter, expansion tank, flow meter, and online liquid replenishment function. It is pre-installed and tested at the factory to reduce on-site workloads.

 

Performance range

· Heat transfer quantity:350~1500kW
 

Complete CDU System technical parameter
20-80KW CDU technical parameters
Indoor unit models CDU020WCDU030WCDU040WCDU050WCDU060WCDU070WCDU080W
main power supply220V/1Ph/50Hz 
Unit performance parameters
Primary side 35/42 ° C
Secondary side 40/47 ° C
Heat exchange capacity-kw21.132.241.353.262.570.682.1
Secondary side flow rate - m3/h2.583.945.066.517.658.6410.05
Primary side flow rate - m3/h2.583.945.066.517.658.6410.05
Rated power of the unit - kW0.460.590.730.830.911.001.13
Unit FLA-A4.264.264.265.975.975.978.81
Primary side 35/45 ° C,
Secondary side 40/50 ° C
Heat exchange capacity-kw17.126.133.543.150.657.266.5
Primary side mediumSoftened water, ethylene glycol solution
Secondary side mediumDeionized water, coolant
Performance parameters of circulating pump
circulating pump qty1 or 1+1 redundancy
Rated power of circulating pump - kW 0.410.540.680.780.860.951.08
Connection pipe size specifications
Primary side pipeline DN32DN32DN32DN40DN40DN40DN40
Secondary side pipeline DN32DN32DN32DN40DN40DN40DN40
Interface type ClampClampClampClampClampClampClamp
Unit size and weight
Unit width-mm 600600600600600600600
Unit depth-mm 1200120012001200120012001200
Unit height-mm 2000200020002000200020002000
weight-kg 200200200200200200200
Recommended specifications for circuit breakers and cables
Recommended Circuit Breaker Specifications-A 16161616161616
Recommended cable specification - mm2 3*2.53*2.53*2.53*2.53*2.53*2.53*2.5

 

Features

· 10-inch touch screen, multi-level authority control;

· Modular design, can be increased according to the demand;

· (Optional) Double back-up high-efficiency frequency conversion pump automatically adjusts the flow rate according to the loaded condition;

· (Optional) Dual power supply backup;

· Corrosion-resistant 304 stainless steel and above material piping components;

· Standard Shenglin liquid-cooled data center function control system, temperature monitoring, secondary side temperature control, flow and differential pressure control, anti-condensation protection, conductivity monitoring (optional), water turbidity monitoring (optional), water hardness monitoring (optional), PH value monitoring (optional);

· Ultra-quiet motor, low noise, long service life;

· Standard Modbus TCP communication protocol, rich detection, alarm and protection functions in the system, automatic protection of the setup parameters, power-down will not lose the operating parameters and alarm records;

· Provide standard communication protocol, can be customized according to customer demand for special format monitoring protocol;

· Secondary side filtration precision: 25~100 (μm) ultra-wide design range.


Our Advantages
    With Shenglin's cutting-edge design, the CDU enhances the efficiency and dependability of the water cooling system. It boasts six channels that link the main pipeline to the secondary water separator of the water-cooled cabinet, eliminating installation and production errors with the use of clamps and rubber hoses.

    Shenglin's CDU features a multi-stage centrifugal pump for circulating industrial water, ensuring a smooth and reliable flow of coolant. An expansion tank is integrated into the CDU to compensate for temperature fluctuations, maintaining consistent pressure levels and ensuring the system's reliable operation.

    To prevent issues like oxidation corrosion, inadequate circulation, and cavitation of the circulation pump, Shenglin's CDU includes an automatic air vent valve on the top of the makeup water tank/main pipeline. This valve promptly eliminates non-condensable gases from the system.

    Furthermore, Shenglin's CDU is equipped with a 150μm filter in its main path to preserve the quality of the coolant, guaranteeing the steady and secure operation of the entire system



Note: for further information please send me email.