Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Cm90 Series Single Stage Back Pressure Steam Turbine

Price $97880.00
Min Order 1 Set
Availability In Stock
Shipping From Shandong, China
Popularity 318 people viewed
Model NO.:
CM90
After-sales Service:
Global Service
Warranty:
18 Months After Shipment Date
Power:
3000-6000kw
Generator Type:
Alternator
Output Type:
AC Three Phase
Certification:
CCC, ISO, CE
Standard:
Standard
Type:
Pulse Type
Generator:
Synchronous
Motor Type:
Asynchronous
Frequency:
50Hz
Freq:
60Hz
Voltage:
380/430
Heat Resource:
Waste Heat
Boiler Type:
Waste Heat Recovery Boiler
Power Consumption:
Energy Saving
Trademark:
CHENYANG
Transport Package:
Sea Worht
Specification:
3000-6000KW
Origin:
China
HS Code:
8406811000
Product Description
ADVANTAGES OF SMALL SCALE PRESSURE DIFFERENCE COGENERATION SET
- High flexibility
- Low investment and quick back
- Effectively solving the industrial waste heat, differential pressure utilisation
- Reducing costs and increasing efficiency for enterprises, and meeting customer needs.

 NOTE:
- The intake and exhaust pressure is absolute pressure.
- Steam turbine weight 8.5 tons.

CM90 SERIES SINGLE STAGE BACK PRESSURE STEAM TURBINE
CHARACTERISTICS
- Double layer distribution.
- 1~4 pressure levels.
- Suitable for waste heat and co-generation energy use.
- One Curtis wheels 1050mm.
- DEH adjusting system, with multi valves for adjusting.
- Forced lubricating.
- Main shaft speed 3000r/min, after gear box conversion.
- Can design according to customer's requirements.

TECHNICAL SPECIFICATIONS
ModelRated power (kW)Speed (r/min)Intake pressure (MPa)Intake temperature (ºC)Exhaust pressure (MPa)Steam consumption (t/h)
B3-3.43/0.294300030003.434350.2949
B3-3.43/0.49300030003.434350.4910.7
B3-3.43/0.785300030003.434350.78514.15
B3-3.43/0.981300030003.434350.98115.93
B3-3.43/1.57300030003.434351.5725.5
B6-3.43/0.294600030003.434350.2948.53
B6-3.43/0.49600030003.434350.499.66
B6-3.43/0.785600030003.434350.78512.68
B6-3.43/0.981600030003.434350.98114.5
B6-3.43/1.275600030003.434351.27518.76
NOTE:
- The intake and exhaust pressure is absolute pressure.

SUCCESSFUL PROJECTS PRESENTATION
USER: CHHP POWER PLANT COGENERATION PROJECT
MODEL: B5-8.83/2.8
POWER: 5000KW
INTAKE PRESSURE: 8.83MPa FROM HEAT RESOURCE
EXHAUST PRESSURE: 2.8MPa FOR PRODUCTION
GENERATOR: SYNCHRONOUS GENERATOR