Swipe or use the arrows to view product images.
Combustion Program Controller Burner Control Box for Gas Burners Accessories Box Kme11.230c2
| Price | $28.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 344 people viewed |
Model NO.:
KME11.230C2
Application Fields:
Industrial Gas Burner
Certification:
CE, ISO
Condition:
New
Noise Level:
Low
Parts:
Burner Controller
Purpose:
Control Gas
Types:
Burner Control
Usage:
Hydrogen, Nitrogen, Ng and LPG
Name:
Burner Controller
Model:
Kme11.230c2
Brand:
Jate
Power Supply:
230V 50/60 Hz.
Tsamax:
3s
Weight:
Less 1kg
Color:
Black
After Warranty Service:
Video Technical Support
Application/Usage:
Gas Burners Industrial Accessories
Shipping Term:
DHL/UPS/FedEx/TNT
Machine Size:
Medium
Trademark:
JATE
Transport Package:
Carton
Specification:
11*8*7cm
Origin:
China
HS Code:
8302600000
Product Description
MADE IN CHINA-JATE
Combustion Program Controller Burner Control Box For Gas Burners Accessories Gas Burner Controller KME11.230C2Application:
KME...for monitoring and control of single-stage or double-stage gas burners during start-up and intermittent operation. flame monitoring Pass ionization bar or flame detector QRA and auxiliary equipment AGQ3 or use blue flame detector QRC. according to the shell Dimensions, KME... Same burner controller as LGB and LMG
PRODUCT SPECIFICATIONS
item | value |
Condition | New |
Warranty | 1.5 years |
Applicable Industries | Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company |
Weight (KG) | Less 1kg |
Showroom Location | None |
Video outgoing-inspection | Provided |
Machinery Test Report | Provided |
Place of Origin | China |
Brand Name | JATE |
Type | Gas Burner |
Product name | KME22.131C2 Igniter For gas Ignition Control Burner Controller |
Brand | JATE |
Model | KME22.131C2 |
Color | Black |
Power supply | 230V 50/60 Hz. |
| Power consumption | approx. AC 3.5 VA |
Ambient Temperature | -20...+60 °C |
Humidity | < 95 % r.h. |
| Degree of protection | IP 40, with the exception of the connection area |
Application/Usage | Gas Burners Industrial Accessories |
Features:
Combustion control according to EN 298 Strong exhaust burner according to EN 676 Undervoltage detection Monitor air pressure during startup and operation with an air pressure switch Convenient remote reset Various colors display information on error status and operating status A limited number of repetitions Precise control sequence due to the use of digital signal processing After 24 hours of continuous operation, it must be stopped once
Installation Precautions:
The controller unit and other cables must be installed separately from the high voltage ignition cables.
Do not confuse phase and neutral.
Install switches, fuses, grounding, etc. in accordance with local regulations.
Connection diagram showing the application of a grounded neutral wire to the burner control. Ionization current monitoring in the network without connection In the case of a ground conductor, terminal 2 must be routed through an RC unit (Type: ARC 4 668 9066 0). Connect the ground wire. Local regulations must be followed (e.g. protection against electric shock) Because the mains voltage of AC 230 V / 50 Hz produces a current leakage of up to 2.7 mA.
Verify that the maximum amount of current allowed by the terminal is not exceeded.
Do not supply an external mains voltage to the control output of the combustion controller, when the test unit controls the combustion controller (fuel valve, etc.), LME do not connect.
In the absence of a fan, the AGK25 must be connected to terminal 3, otherwise the burner will not start reliably.
For safety, connect the neutral conductor to terminal 2. As shown below, the burner components (fan, ignition compressor, air valve) must be connected to the neutral conductor. The connection between the neutral conductor and terminal 2 is at the control unit The bottom is pre-wired.
The controller unit and other cables must be installed separately from the high voltage ignition cables.
Do not confuse phase and neutral.
Install switches, fuses, grounding, etc. in accordance with local regulations.
Connection diagram showing the application of a grounded neutral wire to the burner control. Ionization current monitoring in the network without connection In the case of a ground conductor, terminal 2 must be routed through an RC unit (Type: ARC 4 668 9066 0). Connect the ground wire. Local regulations must be followed (e.g. protection against electric shock) Because the mains voltage of AC 230 V / 50 Hz produces a current leakage of up to 2.7 mA.
Verify that the maximum amount of current allowed by the terminal is not exceeded.
Do not supply an external mains voltage to the control output of the combustion controller, when the test unit controls the combustion controller (fuel valve, etc.), LME do not connect.
In the absence of a fan, the AGK25 must be connected to terminal 3, otherwise the burner will not start reliably.
For safety, connect the neutral conductor to terminal 2. As shown below, the burner components (fan, ignition compressor, air valve) must be connected to the neutral conductor. The connection between the neutral conductor and terminal 2 is at the control unit The bottom is pre-wired.
Electrical installation of flame detectors:
To exclude interference, it is important to avoid losses in signal transmission:
1.Do not install the detector wires together with other wires - Line capacitance reduces the level of the flame signal - Use a separate cable
2.Check the maximum permissible length of the detector wiring (refer to the «Technical Manual»)
3.The ionization bar is not protected against the risk of electric shock
4.Locate and confirm the location of the ignition electrode and ionization probe so that the ignition spark does not pass over the ionization rod (danger of electrical overload) and checks that affect ionization
5.Insulation resistance - Minimum resistance between ion bar and ground is 50 M- Contaminated detector mounts reduce insulation resistance, thereby supporting creep currents The wiring of the burner should comply with the relevant regulations; grounding the boiler alone is not sufficient
To exclude interference, it is important to avoid losses in signal transmission:
1.Do not install the detector wires together with other wires - Line capacitance reduces the level of the flame signal - Use a separate cable
2.Check the maximum permissible length of the detector wiring (refer to the «Technical Manual»)
3.The ionization bar is not protected against the risk of electric shock
4.Locate and confirm the location of the ignition electrode and ionization probe so that the ignition spark does not pass over the ionization rod (danger of electrical overload) and checks that affect ionization
5.Insulation resistance - Minimum resistance between ion bar and ground is 50 M- Contaminated detector mounts reduce insulation resistance, thereby supporting creep currents The wiring of the burner should comply with the relevant regulations; grounding the boiler alone is not sufficient
Combustion Program Controller Burner Control Box For Gas Burners Accessories Gas Burner Controller KME11.230C2
- Similar Products
Negotiable
1 Piece (MOQ)
Bmax High Production N2o Gas Nitrous Oxide Production Line
Fujian Unite International Co., Ltd.
$1800.00
2 Pieces (MOQ)
Small Liquid Nitrogen Generator Psa N2 Generator for Sale
Jiangyin Yangtian Gas Equipment Co., Ltd.