$899.00
1 sets (MOQ)
9-03 Type Fan Forced Cooling High Pressure Centrifugal Fan
Xinxiang SIMO Blower Co., Ltd.
Swipe or use the arrows to view product images.
Compact Space Saving Design Ceiling Concealed Fan Coil Unit CE Certified
| Price | $200.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 400 people viewed |
Model NO.:
FP-WA
Material:
Stainless Steel
Usage:
for Air Conditioner
Flow Direction:
Centrifugal
Pressure:
Medium Pressure
Certification:
RoHS, CE, CCC
Motor:
AC Motor,Ec Motor
Brand:
Umbrellaclimate
After Service:
18 Months
Fan:
3 Speed Centriugal Fan
Coil:
Aluminum Fins
Filter:
Class EU2
Drain Pan:
with Heat Insulation
Multi-Function:
The Left and Right Connection Are Interchangeable
Product Name:
Fan Coil Unit
Key Words:
Ceiling Concealed Fan Coil
Descriptoin:
Air Conditioning Parts
Trademark:
umbrellaclimate
Transport Package:
Factory Standard
Specification:
1.7 kw ~ 9.9 kw
Origin:
Made in China
HS Code:
84159090
Product Description
Chilled Water Ceiling Concealed Fan Coil Unit
Designed to be installed within false ceilings where minimum mounting space is available.
Concealed Ducted Fan Coils have been specially designed to be installed within false ceilings where minimum mounting space is available. It offers external static pressures suitable for the ducting of treated air to suit the majority of installation requirements.
We offer a complete product range, with multiple row coil designs, accessories for the majority of installation requirements, and constructional features to maximize the product flexibility, such as auxiliary heating coils and auxiliary electrical heaters suitable for on-site or in-stock installation.
Minimizes Costs- Maximizes Flexibility- Optimizes Distribution
a. Cooling mode: b. Heating mode:
- Return air temperature: 27C DB/ 19C WB. - Return air temperature: 20C.
- Inlet/ outlet water temperature: 7C/ 12C. - Inlet water temperature: 50C.
- Water flow-rate: same as cooling mode
Designed to be installed within false ceilings where minimum mounting space is available.
Concealed Ducted Fan Coils have been specially designed to be installed within false ceilings where minimum mounting space is available. It offers external static pressures suitable for the ducting of treated air to suit the majority of installation requirements.
We offer a complete product range, with multiple row coil designs, accessories for the majority of installation requirements, and constructional features to maximize the product flexibility, such as auxiliary heating coils and auxiliary electrical heaters suitable for on-site or in-stock installation.
Minimizes Costs- Maximizes Flexibility- Optimizes Distribution
√ 3-speed centrifugal fan statically and dynamically balanced (for AC version)
√ EC Motor with modulating 0-5 V DC Input(for EC version)
√ Auxiliary Electric Heater Element for installation On-site or In-stock
√ Interchangeable left/right side coil connections
√ Auxiliary 1 row heating coil for installation On-site or in-stock
√ 12,30 and 60 Pa External Static Pressure(ESP) models available (for AC version)
√ Variable External Static Pressures(ESP)up to 60 Pa(for EC version)
√ EC Motor with modulating 0-5 V DC Input(for EC version)
√ Auxiliary Electric Heater Element for installation On-site or In-stock
√ Interchangeable left/right side coil connections
√ Auxiliary 1 row heating coil for installation On-site or in-stock
√ 12,30 and 60 Pa External Static Pressure(ESP) models available (for AC version)
√ Variable External Static Pressures(ESP)up to 60 Pa(for EC version)
AC model + EC model
2 pipe range:
Cooling: 1.7 kw ~ 9.9 kw
Heating: 2.04 kw ~11.7kw
4 pip range:
(with heating coil)
2 pipe range:
Cooling: 1.7 kw ~ 9.9 kw
Heating: 2.04 kw ~11.7kw
4 pip range:
(with heating coil)
| FC-WA(3R)-[Size]-V~ | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | |||||
| Unit Configuration | Configuration | 2-pipe | |||||||||||||
| Number Of Fan Blowers | Single | Twin | Three | Four | Three | Four | |||||||||
| Power Supply | (V/Ph/Hz) | 230 / 1 / 50 | |||||||||||||
| 220 / 1 / 60 | |||||||||||||||
| Operation Control | ~S: Complete function onboard PCB with integrated group control functionality, incl. 1 pc return air sensor and 2 pcs temperature sensors. | ||||||||||||||
| ~T: Terminal strip only. | |||||||||||||||
| Performance Data | Air | Air Flow | H | 3 | m3/hr | 451 | 566 | 758 | 934 | 1179 | 1527 | 1754 | 1991 | 2586 | 2933 |
| M | 2 | 358 | 457 | 615 | 840 | 958 | 1220 | 1605 | 1871 | 2389 | 2666 | ||||
| L | 1 | 278 | 293 | 433 | 571 | 779 | 896 | 1144 | 1573 | 2068 | 2482 | ||||
| Available pressure | H | 3 | Pa | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | ||
| M | 2 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | ||||
| L | 1 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | ||||
| Cooling | Cooling Capacity | H | 3 | Kw | 2.43 | 3.08 | 3.9 | 4.8 | 5.99 | 8.01 | 8.72 | 9.87 | 12.8 | 14.6 | |
| M | 2 | 2.02 | 2.59 | 3.3 | 4.42 | 5.09 | 6.7 | 8.14 | 9.4 | 12 | 13.5 | ||||
| L | 1 | 1.65 | 1.8 | 2.5 | 3.24 | 4.32 | 5.23 | 6.23 | 8.2 | 10.7 | 12.8 | ||||
| Sensible Cooling Capacity | H | 3 | 1.74 | 2.2 | 2.82 | 3.46 | 4.31 | 5.73 | 6.35 | 7.16 | 9.24 | 10.5 | |||
| M | 2 | 1.44 | 1.84 | 2.38 | 3.18 | 3.64 | 4.77 | 5.91 | 6.81 | 8.66 | 9.71 | ||||
| L | 1 | 1.17 | 1.27 | 1.78 | 2.31 | 3.08 | 3.7 | 4.48 | 5.92 | 7.71 | 9.16 | ||||
| Heating | Heating Capacity | H | 3 | Kw | 3.00 | 3.78 | 4.87 | 5.99 | 7.43 | 9.85 | 11.00 | 12.52 | 16.15 | 18.25 | |
| M | 2 | 2.50 | 3.18 | 4.12 | 5.51 | 6.32 | 8.24 | 10.27 | 11.92 | 15.14 | 16.66 | ||||
| L | 1 | 2.04 | 2.21 | 3.12 | 4.04 | 5.36 | 6.43 | 7.86 | 10.4 | 13.5 | 16 | ||||
| Max. Electric Heater Capacity@220V | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
| Sound | Sound Pressure Level ( Outlet ) | dB(A) | 40/38/37 | 44/43/40 | 43/41/37 | 45/43/39 | 49/47/44 | 44/43/39 | 47/46/44 | 52/48/44 | 52/48/44 | 54/52/50 | |||
| Sound Pressure Level ( Inlet + Radiated ) | 43/41/40 | 47/46/43 | 46/44/40 | 48/46/42 | 52/50/47 | 47/46/42 | 50/49/47 | 55/51/47 | 55/51/47 | 57/55/53 | |||||
| Sound Power Level ( Outlet ) | 49/47/46 | 53/52/49 | 52/50/46 | 55/53/48 | 58/56/51 | 53/52/48 | 57/56/53 | 61/57/54 | 61/57/53 | 63/61/60 | |||||
| Sound Power Level( Inlet + Radiated ) | 52/50/49 | 56/55/52 | 55/53/49 | 58/56/51 | 61/59/54 | 56/55/51 | 60/59/56 | 64/60/57 | 64/60/56 | 66/64/63 | |||||
| Electrical | Fan Motor Power | H | 3 | W | 82 | 105 | 139 | 154 | 206 | 261 | 288 | 359 | 430 | 511 | |
| M | 2 | 75 | 96 | 128 | 146 | 188 | 238 | 276 | 342 | 365 | 460 | ||||
| L | 1 | 68 | 88 | 111 | 129 | 173 | 216 | 249 | 325 | 345 | 412 | ||||
| Fan Motor Running Current @ H | A | 0.36 | 0.46 | 0.61 | 0.67 | 0.93 | 1.14 | 1.22 | 1.61 | 1.95 | 2.33 | ||||
| Fan Motor Starting Current @ H | A | 1.08 | 1.14 | 1.35 | 1.95 | 2.10 | 2.70 | 3.52 | 4.81 | 5.65 | 6.75 | ||||
| Hydraulic | Cooling Water Flow Rate | 3 | L/h | 417 | 528 | 669 | 827 | 1029 | 1375 | 1498 | 1694 | 2197 | 2501 | ||
| 2 | 347 | 445 | 567 | 758 | 873 | 1150 | 1397 | 1613 | 2064 | 2321 | |||||
| 1 | 283 | 310 | 428 | 557 | 741 | 898 | 1069 | 1408 | 1842 | 2194 | |||||
| Cooling Pressure Drop | 3 | KPa | 18.3 | 30.8 | 17 | 26.7 | 42.8 | 42.7 | 17.3 | 22.7 | 42.2 | 57.2 | |||
| 2 | 13.3 | 22.9 | 12.8 | 23.1 | 32.1 | 31.3 | 15.4 | 20.8 | 37.9 | 50.2 | |||||
| 1 | 9.38 | 12.3 | 7.9 | 13.6 | 24.2 | 20.4 | 9.68 | 16.5 | 31.1 | 45.5 | |||||
| Heating Water Flow Rate | L/h | Same as "Cooling Water Flow Rate" | |||||||||||||
| Heating Pressure Drop | 3 | KPa | 14.75 | 24.82 | 13.7 | 21.6 | 35 | 24.8 | 14 | 18.6 | 34.7 | 47.4 | |||
| 2 | 10.72 | 18.45 | 10.3 | 18.7 | 26.3 | 25.5 | 12.5 | 17 | 31.2 | 41.6 | |||||
| 1 | 7.56 | 9.91 | 6.36 | 11 | 19.8 | 16.6 | 7.85 | 13.5 | 25.6 | 37.7 | |||||
| water content | L | 0.72 | 0.87 | 1.02 | 1.17 | 1.32 | 1.92 | 2.07 | 2.22 | 2.59 | 2.84 | ||||
| Construction and Packing Data | Water | Type | Socket(Threaded Female) | ||||||||||||
| Connections | In | mm [in] | 3/4" | ||||||||||||
| Out | |||||||||||||||
| Condensate Drainage Connection | |||||||||||||||
| Dimensions | L | mm | 755 | 855 | 955 | 1155 | 1255 | 1655 | 1755 | 1855 | 1755 | 1955 | |||
| W | 550 | 620 | |||||||||||||
| H | 250 | 300 | |||||||||||||
| Net Weight | Kg | 17 | 23 | 24 | 28 | 31 | 36 | 43 | 45 | 51 | 60 | ||||
a. Cooling mode: b. Heating mode:
- Return air temperature: 27C DB/ 19C WB. - Return air temperature: 20C.
- Inlet/ outlet water temperature: 7C/ 12C. - Inlet water temperature: 50C.
- Water flow-rate: same as cooling mode