Cross Flow Fan Side Blowing for Dry-Type Transformer
| Price | $50.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Shanghai, China |
| Popularity | 346 people viewed |
Model NO.:
GFDD1000-120
After-sales Service:
24h
Warranty:
12m
Type:
Air-Cooled
System Type:
Closed System
Fans Species:
Single-speed Fan
Noise Level:
Low
Application Fields:
Machinery
Certification:
ISO, CE
Condition:
New
Cooling Capacity:
600kw
Fan Type:
Axial Fan
Voltage:
380V/3p/50Hz
Radiator Material:
Alumium
Trademark:
Coxin
Transport Package:
Plywooden Case
Origin:
China
HS Code:
8414599099
Product Description
[#Transformer Air Oil Cooler#] Cross-flow Fan/Blower *Introduction
Summary
Cross-flow air cooling fans for top-blown dry-type transformers. (below named: dry-transformer cross-flow cooling fan) is mainly used for dry-type transformer cooling to increase capacity, also forced cooling and air supply of electronic equipment, high and low voltage distribution cabinets and other equipment. The cooling fan has the characteristics of large air volume, low noise, high wind pressure, stable operation, compact structure, convenient installation and beautiful appearance.After the dry-type transformer is equipped with the fan to dissipate heat, the capacity can be increased by 40~50%, thereby greatly improving the bearing capacity of the dry-type transformer and prolonging the service life of the dry-type transformer.
Cooling fan operating conditions
1. Normal use conditions:
a. Indoor use;
b. Ambient temperature: -5ºC~+40ºC:
c. The relative humidity of the air is not more than 95% (at 25°C);
d. The altitude does not exceed 1000m;
2. The gas passing through the cooling fan is not allowed to contain strong acid, strong and various erosive solutions.
3. Dust and other sundries are not allowed to fall into the fan, so as not to cause the fan to burn and the fan blades to break.
Installation and maintenance of cooling fans
1. Before installation, check whether there is damage or deformation caused by packaging and transportation. If there is damage or deformation, it should be repaired and installed.
2. Then check whether the parts and screws are loose, and whether the blades and the air duct collide or move. If they collide or shift, they should be adjusted before installation.
3. After the cooling fan is installed, it should be tested and used online after the fan runs normally.
4. When the fan is placed for a long time and reused, it should be used online if there is no abnormal phenomenon during the inspection of the fan.
5. After the fan is installed, the junction box should be sealed to prevent the leakage of the junction box from causing a short circuit to burn the motor.
Handling and storage
1. During the handling process, be careful to handle it with care, handle and place it according to the signs and requirements of the package, and do not put it upside down or upright.
2. Strong impact and violent vibration should be avoided during handling to prevent damage to the packing box and product.
3. The fan should be stored in a ventilated, dry place without corrosive gas to avoid rain and sunlight.
[#Transformer Air Oil Cooler#] Company Profiles*Factory
[#Transformer Air Oil Cooler#] Company Profiles*Exhibitions
[#Transformer Air Oil Cooler#] Company Profiles*Certificates
Summary
Cross-flow air cooling fans for top-blown dry-type transformers. (below named: dry-transformer cross-flow cooling fan) is mainly used for dry-type transformer cooling to increase capacity, also forced cooling and air supply of electronic equipment, high and low voltage distribution cabinets and other equipment. The cooling fan has the characteristics of large air volume, low noise, high wind pressure, stable operation, compact structure, convenient installation and beautiful appearance.After the dry-type transformer is equipped with the fan to dissipate heat, the capacity can be increased by 40~50%, thereby greatly improving the bearing capacity of the dry-type transformer and prolonging the service life of the dry-type transformer.
Cooling fan operating conditions
1. Normal use conditions:
a. Indoor use;
b. Ambient temperature: -5ºC~+40ºC:
c. The relative humidity of the air is not more than 95% (at 25°C);
d. The altitude does not exceed 1000m;
2. The gas passing through the cooling fan is not allowed to contain strong acid, strong and various erosive solutions.
3. Dust and other sundries are not allowed to fall into the fan, so as not to cause the fan to burn and the fan blades to break.
Installation and maintenance of cooling fans
1. Before installation, check whether there is damage or deformation caused by packaging and transportation. If there is damage or deformation, it should be repaired and installed.
2. Then check whether the parts and screws are loose, and whether the blades and the air duct collide or move. If they collide or shift, they should be adjusted before installation.
3. After the cooling fan is installed, it should be tested and used online after the fan runs normally.
4. When the fan is placed for a long time and reused, it should be used online if there is no abnormal phenomenon during the inspection of the fan.
5. After the fan is installed, the junction box should be sealed to prevent the leakage of the junction box from causing a short circuit to burn the motor.
Handling and storage
1. During the handling process, be careful to handle it with care, handle and place it according to the signs and requirements of the package, and do not put it upside down or upright.
2. Strong impact and violent vibration should be avoided during handling to prevent damage to the packing box and product.
3. The fan should be stored in a ventilated, dry place without corrosive gas to avoid rain and sunlight.
[#Transformer Air Oil Cooler#] Company Profiles*Factory
[#Transformer Air Oil Cooler#] Company Profiles*Exhibitions
[#Transformer Air Oil Cooler#] Company Profiles*Certificates
- Similar Products
$8600.00
1 Piece (MOQ)
Industrial Cooling Tower Cooling Machine System
Wuxi Xuelun General Machinery Co., Ltd.