Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Customize Stainless Steel Shell and Tube Heat Exchanger

Price $200.00
Min Order 1 Piece
Availability In Stock
Shipping From Jiangsu, China
Popularity 485 people viewed
Model NO.:
ST20
Certification:
ISO
Application:
Heater
Principle:
Heat Transfer
Style:
Shell and Tube
Material:
Titanium
Weight:
2-4kg
Shell Material:
Carbon Steel, Stainless Steel
Type:
Swimming Pool Titanium Heat Exchanger
Feature:
High Heat Transfer
Trademark:
baode
Transport Package:
Standard Plywood Box
Origin:
China
HS Code:
8419500090
Product Description
Customize stainless steel shell and tube heat exchanger
HOUSEHOLD APPLICATION

floor heating

Swimming pools, tanks with hot water

Defrosting of garage roads, packing
 

INDUSTRIAL APPLICATION

 

oil coolers

 

Coolers of engines and transmission systems

 

Coolers of samples in kettle installation
Operation instructions
It is important that these instructions are followed to prevent any corrosion or erosion of Stainless / Titanium pool & spa heat exchanger.

  1. Operate the unit under the following design parameters shell/tube side pressure: 6 bar (87 psi), Temperature: -5ºC (23ºF)-200ºC (392ºF)
  2. Install unit before chlorination device.
  3. Start-up
  1. Valves should be opened gradually to achieve a steady increase in flow and pressure into the unit
  2. The cold (heated) fluid should first enter in to the system
  3. The hot(heating) fluid, water or steam, should be gradually brought into the system.
  4. Check all connections for leaking.
  1. Shut-Down: shut down hot fluid side first, then the cold fluid side.
  2. (For Stainless heat exchanger only) Always keep PH within correct levels. The ideal pool PH should be kept between 7-8. It is extremely important to avoid PH to fall below 7.2 or above 7.8. you must check daily. Modify your pool condition if necessary.
  3. You must ensure that the chlorine levels are in the range recommended by your pool chemicals supplier and they are aligned to your specific needed.
  4. If you have installed a by-pass fitted to the heat exchanger circuit, it is important that any valve is corrected positioned to allow the recommended pool water flow to pass though the heat exchanger unit.
  5. The filter should be checked regularly,especially sand filters, this type of filtration if working improperly will allow sand to pass around the pool circuit causing erosion of the heat exchanger and other components of the system as well.


 
ModelABCDEF
ST-1626060.00 3603/4"1"48
ST-2542060.00 5203/4"1"48
ST-4535076.00 4501"1 1/2"48
ST-6047076.00 5701 1/2"1 1/2"48



  • Similar Products
Full Page Contact Supplier