Diesel Engine Generator Set Silent 100kVA Mobile Trailer Generator with Cummins Power
| Price | $9460.00 |
|---|---|
| Min Order | 1 set |
| Availability | In Stock |
| Shipping From | Fujian, China |
| Popularity | 294 people viewed |
Model NO.:
GT-80KW
After-sales Service:
1 Year/1000 Hours
Warranty:
1 Year/1000 Hours
Type:
Trailer Type/Movalble Type
Installation Method:
Fixed
Stroke:
Four Stroke
Cooling Method:
Water Cooling
Output Type:
AC Three Phase
Speed:
Speed
Conditions of Use:
Land Use
Usage:
Common Units
Landuse Type of Unit:
Low Noise Automation Type
Excitation Mode:
AC Rotating Exciter
Engine:
with Cummins Engine
Alternator:
Leroy Somer
Model:
Trailer Type(off-Road)
Fuel Tank:
8 Hours Base Fuel Tank
Controller:
Comap/Smartgen
Alternative:
Installing with ATS
Color:
Depends
Voltage:
440V/254V 380V/220V
Trademark:
Gspark
Transport Package:
Wooden Package
Specification:
7CBM
Origin:
Fujian
HS Code:
8502
Product Description
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.
| GT- Series Trailer type Diesel Generators: | ||||||
| Model | Rated Power(KW) | Rated Volt(V) | Rated Current(A) | Fre(Hz) | Installed Generator | Wheels No. |
| GT-15 | 15 | 400V/230V | 27.2 | 50/60 | Leroy Somer | Two |
| GT-20 | 20 | 400V/230V | 36.1 | 50/60 | Leroy Somer | Two |
| GT-24 | 24 | 400V/230V | 43.3 | 50/60 | Leroy Somer | Two |
| GT-30 | 30 | 400V/230V | 54.1 | 50/60 | Leroy Somer | Two |
| GT-40 | 40 | 400V/230V | 72.1 | 50/60 | Leroy Somer | Two |
| GT-50 | 50 | 400V/230V | 90.2 | 50/60 | Leroy Somer | Two |
| GT-64 | 64 | 400V/230V | 115.8 | 50/60 | Leroy Somer | Four |
| GT-75 | 75 | 400V/230V | 135.3 | 50/60 | Leroy Somer | Four |
| GT-90 | 90 | 400V/230V | 162.3 | 50/60 | Leroy Somer | Four |
| GT-100 | 100 | 400V/230V | 180.4 | 50/60 | Leroy Somer | Four |
| GT-120 | 120 | 400V/230V | 216.5 | 50/60 | Leroy Somer | Four |
| GT-150 | 150 | 400V/230V | 271 | 50/60 | Leroy Somer | Four |
| GT-200 | 200 | 400V/230V | 361 | 50/60 | Leroy Somer | Four |
| GT-250 | 250 | 400V/230V | 451 | 50/60 | Leroy Somer | Four |
| GT-300 | 300 | 400V/230V | 541 | 50/60 | Leroy Somer | Four |
| GT-350 | 350 | 400V/230V | 633.5 | 50/60 | Leroy Somer | Four |
| GT-400 | 400 | 400V/230V | 723.2 | 50/60 | Leroy Somer | Four |
| GT-500 | 500 | 400V/230V | 815.1 | 50/60 | Leroy Somer | Four |
-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
| Helpful tips on Generator Set Fault | |||
| When fault occurs during generator set running,could do primary judgement according to following tips. | |||
| Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
| High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
| Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
| Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
| Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
| Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
| Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |