Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Disconnector Outdoor High Voltage Isolation Switch with Insulation Rod

Price $2000.00
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 340 people viewed
Model NO.:
GW1DS
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
1
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification:
ISO9001-2000, CCC
Rated Voltage:
10-23
Rated Frequency:
50/60
Rated Current:
200/400/630/1250
Maximum Operating Voltage:
23
Trademark:
BDN
Transport Package:
Carton
Specification:
medium
Origin:
China
HS Code:
85353090
Product Description

General

 

Outdoor high voltage isolate switch is a single-phase AC frequency 50 Hz / 60HZ high voltage switch equipment .The product is suitable for power system with rated voltage 10kV to  23KV.  It can connect or break the power system under the circumstances of with voltage or non-load.The switch is operated by using insulating rod.

Service environment

 
  • Altitude: no more than 1000m. If the altitude is higher than 1000m, the rated insulation level shall be corrected accordingly.

  • Ambient temperature: upper limit + 45 0C, lower limit - 40 0C, average temperature of the hottest month 30 0C, maximum daily temperature difference 25K.

  • Solar radiation intensity (outdoor): 0.1W/cm2

  • Wind speed / pressure (outdoor): 34m/s  /  700Pa

  • Pollution level: e-level

  • Icing thickness: not more than 20mm

  • Humidity: average daily relative humidity, not more than 95%, average monthly relative humidity not more than 80%

  • Earthquake resistance: horizontal acceleration 0.3m/2, vertical acceleration 0.15m/s2

  • Safety factor: sinusoidal resonance three cycle wave, safety factor above 1.67.

Key Feature

 
  • GW1-10 type outdoor AC high voltage isolation switch is composed of three identical single-pole isolation switches.

  • In the installation, the three poles are formed into a whole by the pipe connecting rod, and the CS8-1 manual operation mechanism is used.

  • Each single-pole isolation switch has a separate iron frame with two post insulators installed at both ends and contacts installed on them.

  • There is a rotating shaft in the middle of the iron frame, and the tool brake is closed by means of a tie rod insulator.

Product Parameters

NameUnitData
Rated voltagekV101520
Maximum operating voltagekV127.523
Rated insulation level1 min power frequency withstand voltageTo earthkV404050
Open contactkV474760
Lightning shock withstand voltage(peak)To earthkV105105125
Open contactkV120120145
Rated frequencyHz 50 
Rated currentA200400  6301250
4S thermal stable current(effective value)kA6.312.5  2031.5
Dynamically-stable current(peak)kA1631.5  5080

Certifications

 

Workshop

 

Packaging & Shipping

 

  • Similar Products
Full Page Contact Supplier