Disposable Invasive Blood Pressure Transducer IBP DPT Transducer for Abbott

Price $6.00
Min Order 10 Pieces
Availability In Stock
Shipping From Guangdong, China
Popularity 486 people viewed
Model NO.:
JIBPT-01-YP
Type:
Surgical Supplies Materials
Ethylene Oxide Sterilization:
Ethylene Oxide Sterilization
Logo Printing:
with Logo Printing
Material:
High Polymer Material and Electronic Chips
Quality Guarantee Period:
Three Years
Group:
Adult/Chidren
Name:
Disposable Pressure Transducer Kit
Properties:
Medical Materials & Accessories
Usage:
Hospital, Clinic, ICU Room
Certificate:
CE/ISO13485/TUV
Feature:
with Flush Device
Packing:
100PCS/Carton/53*46*45cm
Model Number:
Single /Double/Triple Channel Kit
Product Features:
Compatiable Adapter
Function:
to Measure The Pressure of Blood
Stock:
Yes
Trademark:
JCR
Transport Package:
Sterile Blister Box,
Specification:
Compatible with Abbott Single Channel
Origin:
Shenzhen, China
HS Code:
9018909991
Product Description
Disposable Pressure Transducer Kit

Disposable Pressure Transducer is used in ICU Anesthesiology and enable to consist and accurate reading of arterial and venous blood pressure measurement.
 
Available with flushing of 3cc/hr, 30cc/hr or without flush valves.

- Infusion set 
- Pressure monitoring line 
- Stopcock etc 
- Infusion set 
- Pressure monitoring line
- Stopcock etc
- Medical disposable

 
Properties
Medical Materials & Accessories
Product Name
Abbott disposable IBP transducer
Brand Name
JCR
Model Number
JIBPT-01-YP

Detailed Photos

Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years