Eaton 93e UPS 80kVA 100kVA 120kVA 160kVA 400kVA 380V PF 0.9 Three Phase Pure Sine Save Online UPS for Data Center

Price $42587.00
Min Order 1 Piece
Availability In Stock
Shipping From Guangdong, China
Popularity 448 people viewed
Model NO.:
Eaton 93E UPS
Phase:
Three Phase
Type:
On-line
Protection:
Short Circuit
Application:
Communication
Classification:
Lighting/Power
Standby Time:
Standard Machine
Standby UPS:
Sine Wave Output UPS
Output Capacity:
Large Type
Equipment Mode:
Decentralized/Centralized Model
Brand:
Eaton
Power Level:
100kVA-500kVA
Rated Voltage:
380VAC/220VAC
Product Type:
Tower UPS
Frequency:
50/60Hz
Audible Noise:
55-73dB
Crest Factor:
3:01
Ess Mode:
98%
Operating Temperature:
0~40ºC
Storage Temperature:
-25~55ºC
Input Voltage:
380VAC/220VAC
Output Voltage:
380VAC/220VAC
Bypass Voltage:
380VAC
Battery Types:
VRLA, AGM, Gel Batteries, or Eaton Lithium Batteri
Charging Time:
8 Hours to Reach 90% of Full Capacity
Connection:
RS-232, Mini-Slot Communication Slot
Trademark:
Eaton
Origin:
China
HS Code:
8504402000
Product Description
 
TECHNICAL SPECIFICATIONS1 
Power 
Ratings80kVA/72kW, 100kVA/90kW, 120kVA/108kW
160kVA/144kW, 200kVA/180kW
300kVA/270kW, 400kVA/360kW
 
 
 
TopologyDouble-conversion online UPS 
Electrical Input400/230V,4 wire (380/415V selectable) 
Input Voltage Range -15%, +20% from nominal (400V) at 100%
load without depleting battery
 
 
Operating Frequency50/60 Hz(40 to 72 Hz) 
Input Power Factor>0.99 typical 
Input Current Distortion≤5%THD 
Electrical output 
Nominal Output Voltage400/230,4 wire (380/415V selectable) 
Output Voltage Regulation±1% Static;±5% dynamic at 100% resistive
Load change,<20 ms response time
 
 
Battery 
Battery 216/240 Cells (Selectable) 
Charging Method ABM Cyclic Charging 
General 
Efficiency Up to 98.5%High-efficiency mode
Up to 94%Double-conversion mode
 
 
UPS Bypass Automatic on overload or UPS failure 
Dimensions Wx Dx H 600x800x1876(mm)80-200kVA
1600x820x1880(mm)300/400kVA
 
 
Cabinet rating P20 with standard washable dust filters 
Weights 80/100kVA-283 kg,120kVA-311 kg
160/200kVA-457 kg.300/400kVA-1090 kg
 
 
Overload150%for 1 minute,125%for 10 minutes
>150%for 150ms
 
 
Communications 
DisplayGraphical LCD with blue backlight 
LEDs(4)LEDs for notice and alarm 
Audible AlamsYes 
Communication Ports(1)RS-232,(1)USB,(1)EPO 
Communication Slot(2)Mini-slot communication bays 
Environmental 
Operating Temperature0ºCto+40ºC;
Batteries recommended max.+25ºC
 
 
Storage Temperature-25ºC to +55ºC without batteries
+15ºC to+25ºC with batteries
 
 
Relative Humidity5-95%,non-condensing 
Audible Noise80-120kVA≤65 dBA at 1m typica
160-200kVA≤70 dBA at 1m typica
400kVA≤73 dBA at 1m typica
 
 
 
Altitude   <1000m at+40ºC 
Certifications 
EMI StandardsEN55022/EN55024 
FMC ComplianceEC 62040-2 
QualityS09001:2000 and ISO 14001:1996 
Accessories 
Top Cable Entry (80-200kVA,standard on 300-400kVA 
Maintenance Bypass Switches and System Parallel Modules 
Battery Cabinets &Battery Circuit Breakers,IP21 hood (80-200kVA) 
 
Product Description
Company Profile
Certifications

Packaging & Shipping

FAQ

1. May I take some samples to test before I placing the order?
    Yes, we can offer sample testing for you to verify product quality and performance.

2. What is the warranty?
    We support 1 years warranty.

3.What can you buy from us?
   Eaton, Vertiv, APC, Santak, Vesion & OEM/ODM UPS; Cooling, MDC, PDU and so on.

4. What payment methods does your conmpany support?
    We could accept T/T, credit card, Alipay or L/C at sight.

5. What are the terms can you offer for us?
    We could offer EXW, FOB, CIF, DDP and so on.

 
  • Similar Products
Full Page Contact Supplier