$0.94
3000 Pieces (MOQ)
Durable 1500ml Square Mouth Hot Water Bottle with Two-Sided Design
China Yangzhou Baohuilai Co., Ltd.
Swipe or use the arrows to view product images.
Engin Hospital Equipment Bluetooth Portable Oxygen Finger Pulse Oximeter
| Price | Negotiable |
|---|---|
| Min Order | 10 Pieces |
| Availability | In Stock |
| Shipping From | Jiangsu, China |
| Popularity | 382 people viewed |
Model NO.:
EG-OXM
Usage Mode:
For Oral Administration
Nature:
No
Customized:
Customized
Type:
Oxygen Detector
Group:
Middle-aged and Old
Certification:
CE, GMP, ISO
Trademark:
Engin
Transport Package:
Cartoon
Specification:
75*40*42
Origin:
China
Product Description
ENGIN Medical
Immediately Shipment Manufacturer Hospital Medical Equipment Ce and FDA Approved Fingertip TFT LED OLED Color Digital Portable Handheld Finger Pulse Oximeter
Immediately Shipment Manufacturer Hospital Medical Equipment Ce and FDA Approved Fingertip TFT LED OLED Color Digital Portable Handheld Finger Pulse Oximeter
Features:
1. Integrated with SpO2 probe and processing display module
2. Small in volume\light in weight and convenient in carrying
3. Operation of the product is simple, low power consumption
4. SpO2 value display
5. Pulse rate value display, bar graph display
6. Low-voltage indication: Low-voltage indicator appears before working abnormally which is due to low-voltage
7. Automatically power off function: When the device is under the state of measuring interface. It will automatically power off within 5 seconds if the finger falls out of probe
8. Various color of cover can be selected(Yellow, Blue, Light Blue, White, Balck, Pink)
| Display Mode | LED / TFT display |
| SpO2 Measuring Range | 0%~100%, (the resolution is 1%) |
| Accuracy: 70%~100% | ± 2%, Below 70% unspecified. |
| PR Measuring Range | 25bpm~250bpm, (the resolution is 1bpm) |
| Accuracy | ± 1bpm or ± 1% (select larger) |
| Measurement Performance in Weak Filling Condition | SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ± 2 bpm or ± 2% (select larger) |
| Resistance to Surrounding Light | The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1% |
| Power Consumption | Less than 40 mA |
| Voltage | DC 3.0V |
| Power Supply | 1.5V (AAA size) alkaline batteries × 2 |
| Battery Working Hour | The minimum continually work time is 24 hours, theoretical number is 56 hours |
| Safety Type | Interior Battery, BF Type |