Factory-Direct Stainless Steel Vortex Sensor for Petroleum and Power Use
| Price | $240.00 |
|---|---|
| Min Order | 5 pcs |
| Availability | In Stock |
| Shipping From | Henan, China |
| Popularity | 295 people viewed |
Pipeline Vortex Flowmete
Vortex flow sensor measuring the flow of liquid of steam, gas and low viscosity according to Carmen and Strouhal relevant spiral produce and on the theory of the flow relationship. As shown in Figure - a triangular column is vertically inserted into the table body, which is the generating body of vortex. When there is medium flowing through the table body, Carmen vortex with opposite direction and regularity is alternately generated behind the triangular column. The separation frequency F of vortex is proportional to the flow velocity V of medium.Through the number of vortices detected by the sensor head, the fluid velocity can be calculated, and then the volume flow of the measured medium can be calculated according to the body diameter.
| Measuring medium | Gas, Liquid, Steam | |
Caliber | Flange-clamping type | DN15~DN300 |
| Flange type | DN15~DN300 | |
| Inserted type | DN150~DN3000 | |
| Measuring velocity range | Gas 5 ~ 50M / S (can be expanded to 65m / s); | |
| liquid 0.5 ~ 5m / S (can be expanded to 7m / s) | ||
| Measurement accuracy | Flange clamping type and flange type: 1.0 and 1.5 | |
| The accuracy of insertion measuring head is 1.0 The accuracy of inserting industrial pipe is 2.5 | ||
| Temperature of medium | Normal temperature: - 25 ºC ~ 100 ºC, high temperature: - 25 ºC ~ 150 ºC or - 25 ºC ~ 300 ºC | |
| Nominal pressure | 1.6Mpa; 2.5MPa; 4.0Mpa (available according to order) | |
| Output signal | Pulse voltage output signal | High level 8 ~ 10V, low level 0.7 ~ 1.3V (explosion proof type: high level 4 ~ 5V, low level 0.7 ~ 1.3V) |
| The pulse duty cycle is about 50%, and the transmission distance is 100 meters | ||
| Standard voltage output signal | DC4 ~ 20mA allows external load resistance less than 600 Ω (power supply is 24 V), and the transmission distance is 3000 m | |
| Instrument environment | Temperature: - 25 ºC ~ + 55 ºC Humidity: 5 ~ 90% RH (50 ºC) | |
| Material | The body is made of SS304, the converter housing is made of aluminum alloy, and the body is made of SS316 | |
| Power Supply | DC12V ± 10%; DC24V ± 10%; Lithium battery 3.6V 7.5Ah x 2 | |
| Explosion proof grade | Intrinsically safe exiallct1-t5, explosion-proof exdllbt4 | |
| Protection level | IP65 | |
Vortex flow sensor measuring the flow of liquid of steam, gas and low viscosity according to Carmen and Strouhal relevant spiral produce and on the theory of the flow relationship. As shown in Figure - a triangular column is vertically inserted into the table body, which is the generating body of vortex. When there is medium flowing through the table body, Carmen vortex with opposite direction and regularity is alternately generated behind the triangular column. The separation frequency F of vortex is proportional to the flow velocity V of medium.Through the number of vortices detected by the sensor head, the fluid velocity can be calculated, and then the volume flow of the measured medium can be calculated according to the body diameter.
| Measuring medium | Gas, Liquid, Steam | |
Caliber | Flange-clamping type | DN15~DN300 |
| Flange type | DN15~DN300 | |
| Inserted type | DN150~DN3000 | |
| Measuring velocity range | Gas 5 ~ 50M / S (can be expanded to 65m / s); | |
| liquid 0.5 ~ 5m / S (can be expanded to 7m / s) | ||
| Measurement accuracy | Flange clamping type and flange type: 1.0 and 1.5 | |
| The accuracy of insertion measuring head is 1.0 The accuracy of inserting industrial pipe is 2.5 | ||
| Temperature of medium | Normal temperature: - 25 ºC ~ 100 ºC, high temperature: - 25 ºC ~ 150 ºC or - 25 ºC ~ 300 ºC | |
| Nominal pressure | 1.6Mpa; 2.5MPa; 4.0Mpa (available according to order) | |
| Output signal | Pulse voltage output signal | High level 8 ~ 10V, low level 0.7 ~ 1.3V (explosion proof type: high level 4 ~ 5V, low level 0.7 ~ 1.3V) |
| The pulse duty cycle is about 50%, and the transmission distance is 100 meters | ||
| Standard voltage output signal | DC4 ~ 20mA allows external load resistance less than 600 Ω (power supply is 24 V), and the transmission distance is 3000 m | |
| Instrument environment | Temperature: - 25 ºC ~ + 55 ºC Humidity: 5 ~ 90% RH (50 ºC) | |
| Material | The body is made of SS304, the converter housing is made of aluminum alloy, and the body is made of SS316 | |
| Power Supply | DC12V ± 10%; DC24V ± 10%; Lithium battery 3.6V 7.5Ah x 2 | |
| Explosion proof grade | Intrinsically safe exiallct1-t5, explosion-proof exdllbt4 | |
| Protection level | IP65 | |
Our company never forgets its industrial responsibility and social responsibility. Every year, we carry out cash poverty alleviation and goods donations to society, poor families, schools, medical care, etc. On a regular basis, which has been widely recognized by the society.
- Similar Products