Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

GSM3E series of adjustable Molded Case Circuit Breakers MCCB

Price $200.00
Min Order 1 Piece
Availability In Stock
Shipping From Gansu, China
Popularity 267 people viewed
Model NO.:
GSM3E
Breaking Capacity:
Low Voltage Circuit Breakers
Operation:
Energy-storage Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Air
Installation:
Vertical, Horizontal
Structure:
MCCB
Poles Number:
3P, or 4P
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification:
CE
Operation ambient temperature:
-25 to 75 centigrade
Altitude:
2000m, if higher than 2000m, derate
Class of pollution:
3
Installation category:
3
Trademark:
TIANSHUI 213
Transport Package:
Carton
Specification:
IEC60947-2
Origin:
China
HS Code:
8536200000
Product Description

GSM3E series of adjustable molded case circuit breaker (GSM1 MCCB, adjustable)

General Introduction

GSM3E series of adjustable moulded case circuit breaker is used in the circuit breaker of 50Hz or 60Hz, with rated insulation voltage of 800Vdc, with rated voltage up to 690Vac, with rated current from 16A to 1250A. The circuit breaker is equipped with electronic trip unit, and has long time protection, short time protection, instantaneous protection and ground protection, and also has isolating function. Under-voltage release, shunt release, alarming contact, auxiliary contact, motor-operated mechanism are options.

Product Description
ModelGSM3E-125GSM3E-250GSM3E-400GSM3E-630GSM3E-800GSM3E-1250
Frame Current Inm (A)1252504006308001250
Rated current In (A)32631252504006308001250 (800-1250)
Over-load long delay setting current Ir1 (A)16, 20, 25, 3232, 36, 40, 45, 50, 55, 60, 6363, 65, 70, 75, 80, 85, 90, 100, 125100, 125, 140, 160, 180, 200, 225, 250200, 225, 250, 280, 315, 350, 400400, 420, 440, 460, 480, 500, 530, 560, 600, 630630, 640, 660, 680, 700, 720, 740, 760, 780, 800800, 850, 900, 950, 1000, 1050, 1100, 1250
Rated voltage (V)AC400V/AC690VAC400V/AC690VAC400V/AC690VAC400V/AC690V
AC400V
AC400V/AC690VAC400V/AC690V
Rated insulation voltage (V)100010001000100010001000
Rated impulse withstand voltage Uimp (V)800080008000800080008000
Pole number3P
4P
4P3P
4P
4P3P4P3P4P3P4P3P
Breaking capacity levelMHMHMHMHMHMHMHMHMHMHMH
Ultimate short circuit breaking capacity Icu (KA)AC400V508550855085508575100751007510075100751007510075100
AC690V20/20/20/20/20/20/35/35/35/35/35/
Rated service short circuit breaking capacity Ics (KA)AC400V35503550355035507580758075807580758075807580
AC690V10/10/10/10/15/15/25/25/25/25/25/
Rated short time withstand current Icw (KA)/0.5s55581015
Utilization categoryBBBBBB
Flashover distance (mm)5050100100100100
Electrical life (times)80008000750075007500500
Mechanical life (times)Maintainance-free20000200001000010000100002500
With maintainance40000400002000020000200005000
Outline dimension (mm)W92122107142150198210280210280210
H150165257280280340
D828597103103138.5
Net weight (KG)2.0 2.5 2.43.16.38.310.514.210.514.217.8
StandardIEC60947-2/EN60947-2
Operation ambient temperature-25 to +60 centigrade, +andf the averagetemperature within 24 hours shall benot more than 35 certigrade
Altitude (m)2000m, if higher than 2000m, then derate
Class of pollution3
Installation category3 for main circuit and under-voltage release, 2 for others
 
 