Swipe or use the arrows to view product images.
Gas Booster for Oxygen/Nitrogen/Helium/CO2 Cylinder Filling
| Price | $3000.00 |
|---|---|
| Min Order | 1 set |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 506 people viewed |
Model NO.:
DGS-DGT40
Max.Capacity:
>400 L/min
Pressure Medium:
Gas
Certification:
CE, ISO
Material:
Stainless Steel
Power:
Pneumatic
Application:
Increasing Gas Pressure, Transferring and Filling
Boost Medium:
Nitrogen/ Argon/Helium/Hydrogen/CO2/Oxygen or Othe
Certificate:
Ce
Trademark:
SUNCENTER
Transport Package:
1 Set/Case by Plywood Case
Origin:
China
Product Description
Gas booster for oxygen/nitrogen/helium/co2 cylinder filling
Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).
Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.
Applications
Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).
Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.
Applications
- Pressure test with gas
- Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
- Charging of gas cylinder and accumulator with nitrogen
- Supply for isolating gas systems
- Gas assisted injection molding
- Transfer of oxygen cylinders
- Charging of breathing air bottles
- Leak test
- Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
- Safety valve adjusting
Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System
DGS booster system = booster pump+ following valves, gages, and parts
The hottest selling- model A and model C cabinet picture
The standard gas booster pumps system including following parts:
Air -driven gas booster pump (DGA/DGD/DGT three series for choosing)
Stainless steel (carbon steel) material cabinet (Three models for choosing)
F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)
Driven air switch (Pump starting switch), driven air pressure gauge
Gas inlet switch, Gas inlet pressure gauge
Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.
And we could also customize it according to clients' special requirement.
Technical specification for DGS-DGA series
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGS-DGA02 | 2:1 | 1.0 | 16 | 16 | 2-8 bar | 2X PL | 1/2 / 1/2 | 960 (at PA of 6 bar ) |
| DGS-DGA05 | 5:1 | 0 | 40 | 40 | 2-8 bar | 5XPL | 1/2 / 1/2 | 680(at PA of 6 bar ) |
| DGS-DGA10 | 10:1 | 3.5 | 80 | 80 | 2-8 bar | 10XPL | 3/8/ 3/8 | 210(at PA of 10 bar ) |
| DGS-DGA25 | 25:1 | 7.0 | 200 | 200 | 2-8 bar | 25XPL | 1/4/ 1/4 | 120(at PA of 20 bar ) |
| DGS-DGA40 | 40:1 | 10 | 320 | 320 | 2-8 bar | 40XPL | 1/4/ 1/4 | 200(at PA of 40 bar ) |
| DGS-DGA60 | 60:1 | 20 | 480 | 480 | 2-8 bar | 60XPL | 1/4/ 1/4 | 180(at PA of 40 bar ) |
| DGS-DGA100 | 100:1 | 25 | 800 | 800 | 2-8 bar | 100XPL | 1/4/ M14X1.5 | 136(at PA of 40 bar ) |
| DGS-DGA130 | 130:1 | 35 | 800 | 1040 | 2-8 bar | 130XPL | 1/4/ M14X1.5 | 120(at PA of 40 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Technical specification for DGS-DGD series
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGS-DGD10 | 10:1 | 3.5 | 80 | 80 | 2-8 bar | 10XPL+ PA | 3/8/3/8 | 410(at PA of 6 bar ) |
| DGS-DGD25 | 25:1 | 10 | 200 | 200 | 2-8 bar | 25XPL+ PA | 1/4/1/4 | 396(at PA of 20 bar ) |
| DGS-DGD40 | 40:1 | 15 | 320 | 320 | 2-8 bar | 40XPL+ PA | 1/4/1/4 | 320(at PA of 40 bar ) |
| DGS-DGD60 | 60:1 | 25 | 480 | 480 | 2-8 bar | 60XPL+ PA | 1/4/1/4 | 215(at PA of 40 bar ) |
| DGS-DGD100 | 100:1 | 35 | 800 | 800 | 2-8 bar | 100XPL+ PA | 1/4/M14*1.5 | 300(at PA of 60 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Technical specification for DGS-DGT series
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (ZG thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGS-DGT25 | 25:1 | 0.1 | 10 | 200 | 2-8 bar | 25XPL+3.5XPA | 1/4/ 1/4 | 136(at PA of 8 bar ) |
| DGS-DGT40 | 40:1 | 0.1 | 10 | 320 | 2-8 bar | 40XPL+ 6XPA | 1/4/1/4 | 124(at PA of 8 bar ) |
| DGS-DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XPL+6X PA | 1/4/1/4 | 84(at PA of 8 bar ) |
| DGS-DGT25/60 | 25:1/60:1 | 10 | 25 | 480 | 2-8 bar | 60XPL+2.5XPA | 1/4/1/4 | 80(at PA of 15 bar ) |
| DGS-DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100XPL+10XPA | 1/4/ M14*1.5 | 63(at PA of 8 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
How to Select Suncenter Air Driven Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your air compressor) can you offer?( )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime
- Similar Products
$2000.00
1 Piece (MOQ)
15000psi Pressure Calibration Comparator Pump
Beijing Spake Technology Co., Ltd.
$3300.00
1 Set (MOQ)
2000 Bar Portable Pneumatic Hydraulic Pump
SOV Hydraulic Technology (Shanghai) Co., Ltd.
$8.00
100 Pieces (MOQ)
Hand Pressure Testing Pump/Pipe Testing Pump
Zhejiang Lushun Industrial Co., Ltd.
$49.60
100 Pieces (MOQ)
2inch Electrical Stainless Steel Cast Iron Submersible Sewage Water Pump
Taizhou Xuje Pumps Co., Ltd.
$500.00
1 Piece (MOQ)
Water Pressure Vessel for Water Pump
GUANGZHOU BEDFORD ELECTRIC EQUIPMENT CO.,LTD.