Ggd 3phase Switchgear with Reactive Power Factor Correction Bank Power Supply

Price $26.00
Min Order 10 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 268 people viewed
Model NO.:
GGD-400KVAR-3
Type:
Polypropylene Capacitor
Application:
General Purpose, Power
Packaging Type:
Surface Mount
Capacitance:
50-100uf
Structure:
Fixed Capacitor
Manufacturing Material:
Polypropylene
Electrolyte:
Electrolytic
Usage:
Low Frequency Coupling, Tuning, Filter, Low Frequency Bypass
Tuning:
Polystyrene Capacitor
Filter:
Composite Paper Capacitor
Compensate:
Reactive Energy
Power Transformer:
Prove Transmission Power Factor
Using Range:
Motor or Inductive Power
Power Supply:
Only Supply Reactive for Load
Warranty:
2 Years
Di Electrical:
50 Degree Solid Wax
Trademark:
OEM
Transport Package:
Wooden
Specification:
CE ROHS
Origin:
Zhejiang Yueqing
HS Code:
85321000
Product Description
GGD 450V 400KVAR 3Phase  Switchgear  with reactive power factor correction bank power supply 
440v 20kvar three phase exposy resin power capacitor 
active power and passive power.,load have inductive , so it must need reactive ,power capacitor can supply it 

What is reactive power

How does reactive power come into being? The AC system provides two forms of electric energy, active power and passive power.
Active power: All inductive devices operating in the AC system convert electrical energy from the power supply system into mechanical energy and thermal energy, which is called active power.
Reactive power: In order to achieve this transformation, it is necessary to establish magnetic fields in the equipment, and these magnetic fields are related to another form of electrical energy provided in the power supply system, which is called reactive power energy.
The existing forms of reactive power are as follows:
Reactive Power (Transformer, Motor, etc.) Required by Inductance Circuit
Reactive Power (Cable, etc.) Required by Capacitance Circuit
Active power KW = P, reactive power KVAR = Q, inductance reactive power + Q, capacitor reactive power - Q
Apparent power KVA = S
As long as the user has electric load such as motor transformer on site, he will consume reactive power, so the demand for reactive power is just needed for the user.
What is the power factor?
The power factor is the active power KW. The closer the power factor is to the maximum value of 1, the more favorable PF = P (KW)/S (KVA) is for users and power supply departments.
For example, if the power factor is only 0.7, if the power factor is not up to the standard, there will be a penalty for the electricity charge. The power factor reaches 0.95. If the power factor exceeds the assessment index, the power supply bureau will award a calendar.
Increase of efficiency
Correction of Power Factor to Improve Equipment Efficiency