Model NO.:
FM200
Agent:
FM200
Type:
Pipe Type
Object:
Class Abce Fire
Size:
20~450L
Certification:
CCC, GB50370-2005
Power Source:
Pressure Fire Extinguisher
Fire Extinguishing Means:
Total Flooding and Fully-Immersing
System Design Working Pressure:
25bar 42bar 56bar
System Operation Max. Working Pressure:
5.3mpa ~ 5.4mpa
Design Pressure of The Nozzle:
Normal 0.7mpa, Min.0.40mpa
Single Nozzle Protection Radius:
Less 5m
Single Nozzle Protective Height:
Less 5m
Discharging Time:
Less 10s
Gas Filling Rate( Density):
Less 1.15kg/L
Working Temperature:
-10 to +60
System Start Ways:
Automatic Control, Pneumatic Manual and Emergency
Trademark:
WELFARE
Transport Package:
Wooden Case
Specification:
20ltr, 40ltr, 70ltr, 90ltr, 100ltr, to 343ltr
Origin:
Guangzhou
HS Code:
842410000
Product Description
From 1998, We Design, manufacture, installation, Operation and Maintenance HFC-227ea Fire Suppression System
Design According to the following Standard:
China GB795. GB79G, GB410, GB14104, NFPA-2001(U. S. A)
GA400-2002<<Testing Way and Performance of extinguishing system Parts >>
Inside Gas: UL EX6288 describled NFPA2001
Where to use:
Bank data room, gold house,
Painting lines
Generator room, motor room,
Switch board room
Transformer room
Computer and servor room
Communication room
Ware house
All the other place where can not put out the fire by water
Not suitable for extinguishing following fire
1. Oxidizing Chemical and mixture, such as
2. Activitly metal, such as potassium(K), magnesium(Mg), Zirconium( Zr), etc.
3. Metal hydroxide, Potassium hydride, Sodium hydride
4. Miscellaneous fire caused by decomposition Chemical, Such as Hydrogen oxide,
How the System Working:
Gas storage cylinder; 20LTR, 30LTR, 40LTR, 60LTR, 70LTR, 100LTR, 120LTR, 150LTR, 180LTR, 250LTR, 343LTR,
Power Supply: DCV 24, 0.5A
Max Protective Area: 8 Zones (depend on designs)
Three Actuated ways:
Automatic Control
Electric Manual Control
Manual emergency control
System classification
Unit independent system
Means one Fire Suppression system only can protect a protection area. I
Combination and distribute system
Means one fire Suppression system protected several protection area.
Three Part Production constructed whole System
All accessories:
Cylinder +valve +electrical solenoid + pressure gauge+High pressure discharge hose, connecting pipe, manifold pipe, Liquid or gas no Return valve, pressure switch, selection valve ( in multi protection system ), flange, elbow and nozzle
Working pressure: 4.2 Mpa or 2.5Mpa
Discharge time: ≤ 10s
Filling desity: ≤ 950kg/m3
Polit valve powder supply: 6.0± 1.0 Mpa(20C)
System working power: AC 220V DC 24V 1A
System working pressure: -10c~55C
Max protected area: Max 800m² , max volume 3600m³
Working means: Manual, auto, and eletrical
Capacity: 20L, 40L, 70L, 100L, 120L, 150L 180L, 240lLTR, 343LTR
FIRE DETECTS AND ALARMS
Fire control panel +smoke and heat detectors
Fire alarm bell +manual button,
Light warning gas discharging
Before we make offer we need follow technical
Room size: Length width height
Protected subject
Better submit drawing of project
We can send offer within 24 hours after received your informations.
This instruction base conditional Wofu present system, any renew without further Instruction,
Please contact Wofu for more details or newest technical...
Design According to the following Standard:
China GB795. GB79G, GB410, GB14104, NFPA-2001(U. S. A)
GA400-2002<<Testing Way and Performance of extinguishing system Parts >>
Inside Gas: UL EX6288 describled NFPA2001
Where to use:
Bank data room, gold house,
Painting lines
Generator room, motor room,
Switch board room
Transformer room
Computer and servor room
Communication room
Ware house
All the other place where can not put out the fire by water
Not suitable for extinguishing following fire
1. Oxidizing Chemical and mixture, such as
2. Activitly metal, such as potassium(K), magnesium(Mg), Zirconium( Zr), etc.
3. Metal hydroxide, Potassium hydride, Sodium hydride
4. Miscellaneous fire caused by decomposition Chemical, Such as Hydrogen oxide,
How the System Working:
Power Supply: DCV 24, 0.5A
Max Protective Area: 8 Zones (depend on designs)
Three Actuated ways:
Automatic Control
Electric Manual Control
Manual emergency control
System classification
Unit independent system
Means one Fire Suppression system only can protect a protection area. I
Combination and distribute system
Means one fire Suppression system protected several protection area.
Three Part Production constructed whole System
All accessories:
Cylinder +valve +electrical solenoid + pressure gauge+High pressure discharge hose, connecting pipe, manifold pipe, Liquid or gas no Return valve, pressure switch, selection valve ( in multi protection system ), flange, elbow and nozzle
Working pressure: 4.2 Mpa or 2.5Mpa
Discharge time: ≤ 10s
Filling desity: ≤ 950kg/m3
Polit valve powder supply: 6.0± 1.0 Mpa(20C)
System working power: AC 220V DC 24V 1A
System working pressure: -10c~55C
Max protected area: Max 800m² , max volume 3600m³
Working means: Manual, auto, and eletrical
Capacity: 20L, 40L, 70L, 100L, 120L, 150L 180L, 240lLTR, 343LTR
FIRE DETECTS AND ALARMS
Fire control panel +smoke and heat detectors
Fire alarm bell +manual button,
Light warning gas discharging
Before we make offer we need follow technical
Room size: Length width height
Protected subject
Better submit drawing of project
We can send offer within 24 hours after received your informations.
This instruction base conditional Wofu present system, any renew without further Instruction,
Please contact Wofu for more details or newest technical...
- Similar Products
$44.80
1000 Pieces (MOQ)
China Wholesale Empty Fire Extinguisher
Hainan Fifitec Import &Export Co., Ltd.
$79.90
500 Pieces (MOQ)
9L Fluorine Free Extinguisher Used for Putting out a Class Fire
POWER SAINTS LTD.