Swipe or use the arrows to view product images.
High Accuracy Transformer Oil Gas Analyzers Price Dissolved Gas Analysis Equipment GC MS Insulating Oil Gas Chromatograph
| Price | $11980.00 |
|---|---|
| Min Order | 1 Set |
| Availability | In Stock |
| Shipping From | Hebei, China |
| Popularity | 381 people viewed |
Model NO.:
VS-9808
After-sales Service:
24/7 Online Service
Warranty:
1 Year
Appliance:
Biochemistry
Gaspath System:
Three
Certification:
CE, ISO, IEC
Stationary Phase:
Solid Adsorbent
Mobile Phase:
Gas
Chromatography Type:
Gas Chromatography
Chromatographic Column Type:
Convetional Analytical Column
Chromatographic Column Length:
10~30cm
Chromatographic Column Diameter:
20~40mm
Product Name:
Oil Gas Chromatograph
Voltage Range:
0.5~10kv
Test Current Range:
10μa~1A
Power Factor:
0.02 < Cos φ < 0.1
Current Range:
0.5A ~ 15A (Internal), 0.5A ~ 50A (External)
Frequency Measuremen:
45 ~ 65Hz
Ambient Temperature:
-10°c to 50°c
Ambient Humidity:
≤85℅rh, Non-Condensing
Operating Power Supply:
AC220V ±10%
Trademark:
Weshine
Transport Package:
Poly Crate with Foam
Origin:
Baoding, China
HS Code:
9030332000
Product Description
When the highest levels of throughput are critical to your operations, choose the VS-9808GAS CHROMATOGRAPH. Its patented high-performance oven delivers the fastest heat-up and cool-down of any oven in the business, and that means shorter injection-to-injection times, and the ability to run more samples per day. Plus, the oven's twin-wall design with concentric air exhaust provides exceptional cooling to near-ambient temperatures without resorting to liquid cryogen - critical for analysis of VOCs. Weshine invented that VS-9808 has a wide-range flame ionization detector (FID), a new high-performance capillary injector with decreased reactivity, and autosampler technology that delivers multiple options for liquid injection, headspace, and SPME on one system.
Weshine VS-9808 GAS CHROMATOGRAPH specializes in the analysis of gases in transformer insulating oil. The Gas Chromatograph can analyze 7/9/11 kinds of gas components in the insulating oil through two or three chromatographic columns.
Gas Chromatograph works with the Air Generator, Hydrogen Generator, and Oscillator.
The Oscillator shocks and heats up the oil sample to get the gas from the oil. And then inject the gas sample into the Gas Chromatograph. Before that, we should use the Air Generator and Hydrogen Generator to fire the FID1 and FID2.The Gas Chromatograph will analysis the gas sample automatically, and you will see the gases components waves on the software on PC.
The test report can be printed by the printer from the Gas Chromatograph.
If there are many oil samples needed to be tested, then the Headspace Autosampler can help. 27 Samples can be shocked and heated, and then transmit the gas samples automatically by the Autosampler. It can help the Gas Chromatograph a lot, and save labor cost and time cost.
Gas Chromatograph works with the Air Generator, Hydrogen Generator, and Oscillator.
The Oscillator shocks and heats up the oil sample to get the gas from the oil. And then inject the gas sample into the Gas Chromatograph. Before that, we should use the Air Generator and Hydrogen Generator to fire the FID1 and FID2.The Gas Chromatograph will analysis the gas sample automatically, and you will see the gases components waves on the software on PC.
The test report can be printed by the printer from the Gas Chromatograph.
If there are many oil samples needed to be tested, then the Headspace Autosampler can help. 27 Samples can be shocked and heated, and then transmit the gas samples automatically by the Autosampler. It can help the Gas Chromatograph a lot, and save labor cost and time cost.
PRODUCT INFORMATION | |||
Product Name | GAS CHROMATOGRAPH | ||
Operation Display | 5.7 inch lattice localization color LCD | Control Region | 6 pc |
Temperature Range | Column oven temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC | ||
Detection room temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC | |||
Conversion furnace temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC | |||
External Event | 4 channels | Type of Detector | FID, TCD, ECD, FPD |
Standards | ASTM D2887,D7169,D6352 ... | Certificates | CE; EMC; LVD; ISO; IEC; |
Dimensions | 455mm*530mm*220mm | Model Number | VS-9808 |
VS-27
AUTOMATIC HEADSPACE SAMPLER
* Used for GC Sample Preparation & Introduction
* 10ml and 20ml headspace vials can be used to meet a large number of analytical requirements.* The start bottle position and end bottle position can be set freely.
* 6 sample heating positions can be overlapped for heating.
* Automatically detect leaked sample vials.
* Vial shaking function accelerates equilibration time and improves efficiency.
VS-9808
GAS CHROMATOGRAPH
* Patented high-performance oven.
* The fastest heat-up and cool-down in the business.
* Twin-wall design with concentric air exhaust.
* Wide-range flame ionization detector (FID)
* New high-performance capillary injector.
* Autosampler delivers multiple options for liquid injection, headspace, and SPME on one system.
- Similar Products
Negotiable
1 Piece (MOQ)
ID200mm Dac HPLC Column