High Precision Computerized Heat Delfection and Vicat Softening Temperature Tester

Price $2000.00
Min Order 1 Piece
Availability In Stock
Shipping From Hebei, China
Popularity 312 people viewed
Model NO.:
GT-HVT-6
After-sales Service:
Lifetime Maintenance
Warranty:
Lifetime Maintenance
Type:
Material Testing Machine
Control:
Computer Control
Power Source:
AC220V
Controlled by:
Computer
Test Methids:
Vicast Softening & Heat Deflection Temperature
Station Number:
6
Max. Temperatuer:
300ºC
Test Method:
ISO 75, ISO 306, ASTM D 1252, ASTM D 648
Trademark:
GT-TEST
Transport Package:
Wooden Package
Origin:
Beijing
HS Code:
9024800000
Product Description

HDT/Vicat Tester

Standards
  1. ISO 75
  2. ISO 306
  3. ASTM D 1525 
  4. ASTM D 648

Application
The tester is used to determine the Vicat softening temperature and the heat deflection temperature under load for plastics and thermoplastics.
The attained heat resistance rate of plastic material is a widely required parameter for product characterization, for quality control and for evaluating the conformity to the previewed applications.
 "HDT" test means
The test determines the temperature at which a specified deflection occurs when a standard test specimen is subjected to a bending stress, to produce one of the nominal surface stresses according to international standards.
This test is important for both quality control and research into plastics.
"VICAT" test means
The test determines the temperature at which a standard indenter penetrates 1mm into the surface of a test specimen under load.
It is used to establish the difference between many types of thermoplastic materials with regard to their softening properties.

Features
  1. Control mode: computer and application software
  2. Motor-operated lifting platform
  3. The designed volume ensures a very good thermal exchange
  4. Enables to produce the graphs of deflection Vs Time or Temperature
  5. Automatic recording the test results of Vicat /HDT temperatures
Parameters
Number of stations3/4/6
Temperature measuring point1
Temperature range RT to 300ºC
Temperature ramps50ºC/h, 120ºC/h or others on request
Deflection range-1.00 to 9.00mm
Deflection measuring instrumentDigital gauge with communication interface
Test capability HDT & VICAT
Control wayComputer and application software
Test graphsDeflection or Penetration curves Vs Time or Temperature
Span of specimen support (HDT)64 or 100mm
HDT
Flexural stressMethod A-1.8 Mpa
Method B-0.45 Mpa
Method C-8.0 Mpa
Vicat
VICAT mass 10N and 50N
 