Model NO.:
DGT-25
After-sales Service:
13 Monthes
Warranty:
13 Monthes
Max.Head:
>150m
Max.Capacity:
>400 L/min
Pressure Medium:
Gas
Type:
Handheld
Position of Pump Shaft:
Horizontal
Certification:
CE, ISO
Application:
Increasing Gas Pressure, Transferring and Filling
Boost Ratio:
2:1
Boost Medium:
Nitrogen/ Argon/Helium/Hydrogen/CO2/Oxygen or Othe
Material:
Stainless Steel
Certificate:
CE RoHS
Trademark:
SUNCENTER
Transport Package:
1 Set/Case by Plywood Case
Specification:
550*350*250mm
Origin:
China
HS Code:
8414809090
Product Description
Suncenter Helium/Hydrogen/Oxygen/Nitrogen/Natural Gas Booster Pump for sales
Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series
Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Key features include:
Applications
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
Technical spcification
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.
Technical specification
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
2DGD series gas booster pumps(Double acting, double air driven heads ):
Technical specification
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
Technical specification
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
How to Select Suncenter Air Driven Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your air compressor) can you offer?( )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime
Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series
Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Key features include:
- Compressed Air driven - no electricity required (connect to normal air compressor)
- In order to extend the lifetime of the pump, the driving air pressure should
- No airline lubricator required
- Hydrocarbon free - separation between air and gas sections
- Pressures to 80Mpa (11,600 psi)
- Wide range of models with different ratios
- Built-in-cooling on most models
- Easy to install, operate and maintain
- Best price / performance ratio
- No heat, flame or spark risk and explosion proof
- Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
- Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.
Applications
- Pressure test with gas
- Gas transfer and filling
- Charging of gas cylinder and accumulator with nitrogen
- Supply for isolating gas systems
- Gas assisted injection molding
- Transfer of oxygen cylinders
- Charging of breathing air bottles
- Leak test
- Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
- Safety valve adjusting
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGA02 | 2:1 | 1.0 | 16 | 16 | 2bar-8 bar | 2X PL | 1/2 / 1/2 | 960 (at PA of 6 bar ) |
| DGA05 | 5:1 | 0 | 40 | 40 | 2bar-8 bar | 5XPL | 1/2 / 1/2 | 680(at PA of 6 bar ) |
| DGA06 | 6:1 | 2.0 | 48 | 48 | 2bar-8 bar | 6XPL | 1/2 / 1/2 | 360(at PA of 10 bar ) |
| DGA10 | 10:1 | 3.5 | 80 | 80 | 2bar-8 bar | 10XPL | 3/8/ 3/8 | 210(at PA of 10 bar ) |
| DGA25 | 25:1 | 7.0 | 200 | 200 | 2bar-8 bar | 25XPL | 1/4/ 1/4 | 120(at PA of 20 bar ) |
| DGA40 | 40:1 | 10 | 320 | 320 | 2bar-8 bar | 40XPL | 1/4/ 1/4 | 200(at PA of 40 bar ) |
| DGA60 | 60:1 | 20 | 480 | 480 | 2bar-8 bar | 60XPL | 1/4/ 1/4 | 180(at PA of 40 bar ) |
| DGA100 | 100:1 | 25 | 800 | 800 | 2bar-8 bar | 100XPL | 1/4/ M14X1.5 | 136(at PA of 40 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.
- DGD pumps are available with high quality seals, which provide significantly better service life
- Double pump heads with exhaust cooling devices.
- All components in contact with the gas are made of stainless steel.
- Pipes mounting way are available as customized.
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGD10 | 10:1 | 3.5 | 80 | 80 | 2bar-8 bar | 10XPL+ PA | 3/8/3/8 | 410(at PA of 6 bar ) |
| DGD25 | 25:1 | 10 | 200 | 200 | 2bar-8 bar | 25XPL+ PA | 1/4/1/4 | 396(at PA of 20 bar ) |
| DGD40 | 40:1 | 15 | 320 | 320 | 2bar-8 bar | 40XPL+ PA | 1/4/1/4 | 320(at PA of 40 bar ) |
| DGD60 | 60:1 | 25 | 480 | 480 | 2bar-8 bar | 60XPL+ PA | 1/4/1/4 | 215(at PA of 40 bar ) |
| DGD100 | 100:1 | 35 | 800 | 800 | 2bar-8 bar | 100XPL+ PA | 1/4/M14*1.5 | 300(at PA of 60 bar ) |
| DGD130 | 130:1 | 50 | 1040 | 1040 | 2bar-8 bar | 130XPL+ PA | 1/4/M14*1.5 | 180(at PA of 60 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
2DGD series gas booster pumps(Double acting, double air driven heads ):
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at driven air pressure of 6bar (L/min) |
| 2DGD10 | 10:1 | 3 | 80 | 80 | 2bar-8 bar | 2bar-8 bar | 1/2 / 1/2 | 980(at PA of 6 bar ) |
| 2DGD25 | 25:1 | 6 | 200 | 200 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 560(at PA of 10 bar ) |
| 2DGD40 | 40:1 | 25 | 320 | 320 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 480(at PA of 40 bar ) |
| 2DGD60 | 60:1 | 30 | 480 | 480 | 2bar-8 bar | 2bar-8 bar | 3/8 / 3/8 | 320(at PA of 40 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
- DGT pumps are available with high quality seals, which provide significantly better service life
- Double pump heads with exhaust cooling devices.
- All parts in contact with the gas are made of stainless steel.
| Model | Pressure boost ratio | Min. gas Inlet pressure PA (bar) | Max.gas Inlet pressure PA (bar) | Max. gas outlet pressure PB (bar) | Driven air pressure PL | Formula to calculate gas outlet pressure PB | Connection: Gas Inlet / Gas outlet (NPT thread) | Max. flow at driven air pressure of 6bar (L/min) |
| DGT25 | 25:1 | 0.1 | 10 | 200 | 2-8 bar | 25XPL+3.5XPA | 3/8/ 1/4 | 136(at PA of 8 bar ) |
| DGT40 | 40:1 | 0.1 | 10 | 320 | 2-8 bar | 40XPL+ 6XPA | 3/8/ 1/4 | 124(at PA of 8 bar ) |
| DGT10/60 | 10:1/60:1 | 0.1 | 10 | 480 | 2-8 bar | 60XPL+6X PA | 3/8/ 1/4 | 84(at PA of 8 bar ) |
| DGT25/60 | 25:1/60:1 | 10 | 25 | 480 | 2-8 bar | 60XPL+2.5XPA | 3/8/ 1/4 | 80(at PA of 15 bar ) |
| DGT100 | 100:1 | 0.1 | 10 | 800 | 2-8 bar | 100XPL+10XPA | 3/8/ M14*1.5 | 63(at PA of 8 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
How to Select Suncenter Air Driven Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your air compressor) can you offer?( )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)
Product Application
Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.
Our service
13 months' free warranty since the purchasing date and free technical support during lifetime
- Similar Products
$2000.00
1 Piece (MOQ)
Desktop Pressure Calibration Deadweight Tester
Beijing Spake Technology Co., Ltd.
$200.00
10 Pieces (MOQ)
Bedford Series Water Pump Pressure Tank
GUANGZHOU BEDFORD ELECTRIC EQUIPMENT CO.,LTD.
$1400.00
1 Piece (MOQ)
Yanmar 4tne92, 4tne94, 4tne98 Injection Pump
Dongguan Yi Hui Forklift Co., Ltd.
$68.00
20 Pieces (MOQ)
Water Pipes Test Pump 60 Bar High Pressure Pump
Jiangsu Bohui Machinery Manufacturing Co., Ltd.
Negotiable
1 Set (MOQ)
Why3700 Triplex Plunger High Pressure Pump
Wuxi Hongyuan Pump Manufacturing Co., Ltd.