Outdoor on-Load Break Switch Isolator Disconnector
| Price | $2000.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 303 people viewed |
Model NO.:
GRW24
Breaking Capacity:
High Voltage Circuit Breakers
Operation:
Electric Type
Speed:
Normal Type Circuit Breaker
Arc-extinguishing Medium:
Vacuum
Installation:
Fixed
Structure:
ACB
Poles Number:
1
Type:
Circuit Breaker
Function:
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification:
ISO9001-2000, CCC
Rated Voltage:
12/24/36
Rated Frequency:
50/60
Rated Current:
200/400/630
Rated Making Current:
31.5-50
Trademark:
BDN
Transport Package:
Carton
Specification:
medium
Origin:
China
HS Code:
85353090
Product Description
Outdoor on load break switch disconnector contained in this list are destined to switch stub lines and ring main lines or transformers (It can be equipped with MV HRC fuse links as short circuit protection fuction) or for switching under on load conditions. This disconnector complies with IEC/IEEE and DVE-recommendation standards especially comply with DIN VDE 0670 part 3 and IEC 60265, IEC 129.
Ambient Temperature: -40ºC - +50ºC
Altitude: 2500m
Frequency: 50Hz / 60Hz
Maximum Wind Speed: 35m/s
| Name | Unit | Data | ||||
| Rated voltage | kV | 12 | 24 | 36 | ||
| Rated frequency | Hz | 50/60 | ||||
| Rated current | A | 200/400/630 | ||||
| Rated short circuit withstand current (1S) | kA | 20 | ||||
| Rated peak withstand current(1S) | kA | 50 | ||||
| Rated making current | kA | 31.5-50 | ||||
| Rated insulation level (HV) | lightning impulse | kV | 75/85 | 125/145 | 170/195 | |
| Power frequency withstand | 45 | 55/75 | 75/100 | |||
| Rated short circuit breaking capacity cos.Φ(0.7) Without maintenance of contacts | A | / | ||||
| for active circuits | 20 breakings | 630 | 630 | 400 | ||
| 30 breakings | 400 | 400 | 300 | |||
| 40 breakings | 300 | 300 | 250 | |||
| 50 breakings | 250 | 250 | 170 | |||
| 75 breakings | 170 | 170 | 160 | |||
| 120 breakings | 110 | 110 | 110 | |||
| 200 breakings | 65 | 65 | 65 | |||
| 280 breakings | 50 | 50 | 50 | |||
| For ring circuits breaking capacity | 630 | 400 | 250 | |||
| Rated breaking capacity of transformer | 50 | |||||
| Rated breaking capacity of cable charging | 11 | |||||
| Rated breaking capacity of earthing fault | 56 | |||||
- Similar Products
$20.00
10 Pieces (MOQ)
Electric Vigi Earth-Leakage Protection for Nsx Circuit Breaker
Wenzhou Kasan Electric Co., Ltd.
$2000.00
1 Piece (MOQ)
11kv Vacuum Circuit Breaker Pole Mounted High Voltage Switchgear
Chuanyang Electric Co., Ltd