Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

Hook Locking Plate Type I / Type II

Price $60.00
Min Order 1 Piece
Availability In Stock
Shipping From Jiangsu, China
Popularity 506 people viewed
Model NO.:
2, 3 holes
Customized:
Non-Customized
Certification:
ISO, CE
Condition:
New
Usage:
Correct Deformities, Fracture Fixation
Using Site:
Olecranon, Distal Tibia and Fibula
Type:
Internal Fixation
Product Code:
2002
Holes:
2, 3 Holes
Length:
40 mm (2 Holes), 54 mm (3 Holes)
Screw Compatibility:
Ha 2.4 / 2.7mm, Locking Screws 2.4 / 2.7mm
Applicable Patient Site:
Simple Olecranon Fracture, Tibia Avulsion Fracture
Material Type Details:
Medical-Grade Titanium (Ta3g) for Biocompatibility
Compatibility:
Compatible with Ao/Asif System
Surgical Approach:
for Olecranon, Distal Tibia and Fibula Fracture
Anatomic Fit:
for Olecranon, Distal Tibia and Fibula Stablize
Biomechanical Properties:
High Resistance to Bending and Torsion
Finish:
Polished Surface for Reduced Tissue Irritation
Surgical Indication:
Humerus Fractures Requiring Surgical Stabilization
Sterility:
Non-Sterile, Requires Sterilization Before Use
Reusable or Single-Use:
Single-Use Implant
Contraindications:
Active Infection at The Surgical Site
Trademark:
BEST MEDICAL
Transport Package:
1 PC/Package
Specification:
Medical grade Titanium
Origin:
China
HS Code:
9021100000
Product Description
Product Description

 

Type I: Hook Locking Plate (L/R)

Features:
  • Hooked Design: The Type I plate features two hooks designed to provide additional fixation at the distal end of bones such as the ulna or tibia, ensuring secure anchoring of avulsion fractures.
  • Titanium Material: Made of high-strength titanium, which offers excellent biocompatibility, durability, and resistance to corrosion.
  • Hole Configurations: Available in 2 and 3-hole configurations, allowing for flexible screw placement based on fracture type and location.
  • Locking Screws Compatibility: Compatible with HA 2.4 mm/2.7 mm locking screws, providing rigid fixation for fractures.
  • Bilateral Use: Can be used for both left (L) and right (R) limbs, providing flexibility in surgical application.
 
Indications

Intended Use:

The Type I Hook Locking Plate (L/R) is designed for the surgical fixation of distal ulnar and tibial avulsion fractures. It offers stable fixation and promotes bone healing in cases of trauma or avulsion injuries, particularly in small bone fragments.

Indications:
  • Distal ulnar avulsion fractures requiring surgical fixation.
  • Distal tibial avulsion fractures.
  • Small fragment fractures of the distal ulna and tibia.
  • Comminuted fractures requiring rigid fixation with locking screws.
  • Open or closed fractures where stability is required.
 
Contraindications

Contraindications:

  • Active infection at the surgical site.
  • Severe osteoporosis or insufficient bone stock for secure fixation.
  • Known allergies to titanium or other implant materials.
  • Fractures that can be treated non-surgically or without surgical intervention.
 
Product Parameters

Type I: Hook Locking Plate (L/R) - Product Parameters

ParameterDetails
Product NameHook Locking Plate Type I (L/R)
MaterialHigh-strength, biocompatible titanium
Surface TreatmentPolished or anodized for corrosion resistance
Plate TypeLocking plate with double hooks
Available VersionsLeft (L) and Right (R)
Holes Configuration2, 3 holes
Plate Length (mm)40 mm (2 holes), 54 mm (3 holes)
Screw CompatibilityHA 2.4 / 2.7mm, Locking screws 2.4 / 2.7mm
IndicationsUlnar and tibial avulsion fractures
ContraindicationsActive infection, poor bone quality, allergies to titanium
Sterilization MethodProvided in unsterile packaging, requires sterilization before surgery
Fixation TypeRigid fixation using locking screws
Intended Surgical ApproachOpen reduction and internal fixation (ORIF) for distal fractures
PackagingUnsterile packaging, requires sterilization before use
CE CertificationCertified for use in international markets
Shelf Life5 years when stored in appropriate conditions
RadiolucencyCompatible with imaging modalities like X-ray, CT
CustomizationAvailable in different lengths for patient-specific needs
Usage EnvironmentOperating room, under sterile conditions
______________________________________________________________________________________________________________________
 
 
Type II: Hook Locking Plate (L/R)

Features:
  • Single Hook Design: The Type II plate features a single hook, designed for use in fractures where a simpler anchoring solution is needed at the distal bone end, such as the ulna or tibia.
  • Titanium Material: Constructed from high-strength titanium, ensuring biocompatibility, durability, and excellent corrosion resistance.
  • Hole Configurations: Available in 2 and 3-hole configurations, providing flexibility for screw placement depending on the fracture and anatomical location.
  • Locking Screws Compatibility: Compatible with HA 2.4 mm/2.7 mm locking screws, offering stable and secure fixation.
  • Bilateral Use: Designed for use on both left (L) and right (R) limbs, allowing for a versatile approach to various fractures.

Intended Use:
The Type II Hook Locking Plate (L/R) is used for the surgical treatment of distal ulnar and tibial avulsion fractures. It provides stable fixation for smaller fractures, particularly in cases where simpler fixation is appropriate.

Indications:
  • Distal ulnar and tibial avulsion fractures requiring surgical stabilization.
  • Simple avulsion fractures where the fragment requires secure fixation.
  • Open or closed fractures of the distal ulna or tibia.
  • Small fragment fractures requiring locking screws for fixation.

Contraindications:
  • Active infection at the surgical site.
  • Insufficient bone stock or severe osteoporosis.
  • Known allergies to titanium or other implant materials.
  • Fractures that do not require surgical fixation.

Type II: Hook Locking Plate (L/R) - Product Parameters
ParameterDetails
Product NameHook Locking Plate Type II (L/R)
MaterialHigh-strength, biocompatible titanium
Surface TreatmentPolished or anodized for corrosion resistance
Plate TypeLocking plate with single hook
Available VersionsLeft (L) and Right (R)
Holes Configuration2, 3 holes
Plate Length (mm)40 mm (2 holes), 54 mm (3 holes)
Screw CompatibilityHA 2.4 mm / 2.7 mm, Locking screws 2.4 mm / 2.7 mm
IndicationsUlnar and tibial avulsion fractures
ContraindicationsActive infection, poor bone quality, allergies to titanium
Sterilization MethodProvided in unsterile packaging, requires sterilization before surgery
Fixation TypeRigid fixation using locking screws
Intended Surgical ApproachOpen reduction and internal fixation (ORIF) for distal fractures
PackagingUnsterile packaging, requires sterilization before use
CE CertificationCertified for use in international markets
Shelf Life5 years when stored in appropriate conditions
RadiolucencyCompatible with imaging modalities like X-ray, CT
CustomizationAvailable in different lengths for patient-specific needs
Usage EnvironmentOperating room, under sterile conditions

Inside Our Company

  • Similar Products
Full Page Contact Supplier